Part Number

Search

REC10-2415SZ/H3/M

Description
DC DC CONVERTER 15V 10W
CategoryPower/power management   
File Size108KB,2 Pages
ManufacturerRECOM Power GmbH
Websitehttps://www.recom-power.com/
Environmental Compliance
Download Datasheet Parametric View All

REC10-2415SZ/H3/M Overview

DC DC CONVERTER 15V 10W

REC10-2415SZ/H3/M Parametric

Parameter NameAttribute value
typeisolation module
Number of outputs1
Voltage - Input (minimum)9V
Voltage - input (maximum)36V
Voltage - Output 115V
Voltage - Output 2-
Voltage - Output 3-
Current - Output (maximum)667mA
Power (W)10W
Voltage - Isolation3kV
applicationITE (Business)
characteristicRemote on/off, OCP, SCP, UVLO
Operating temperature-40°C ~ 71°C
efficiency86%
Installation typeThrough hole
Package/casing24-DIP module
size/dimensions1.26" long x 0.80" wide x 0.40" high (32.0mm x 20.3mm x 10.2mm)
Control characteristicsEnable, active high level
Features
Regulated
Converters
10W in 2” x 1” Package
2kVDC and 3kVDC Isolation Options
2:1 or 4:1 Input Voltage Range
Continuous Short Circuit Protection
(power limiting)
Synchronous Rectification on all Del outputs
Full SMD internal design
Remote Control Pin
Efficiency to 87%
ECONOLINE
DC/DC-Converter
with 3 year Warranty
Description
The REC10-xxxxS_D/M -series offer single and dual regulated outputs in a 2”x1” package with
2kVDC or 3kVDC isolation options and are suitable for higher power industrial applications. Re-
mote on/off control is standard. The converters can deliver 150% rated power for short periods
of time to cope with applications with large capacitive loads or high start up currents.
Selection Guide
Part
Number
REC10-xx3.3S/H*/M
REC10-xx05S/H*/M
REC10-xx12S/H*/M
REC10-xx15S/H*/M
REC10-xx05D/H*/M
REC10-xx12D/H*/M
REC10-xx15D/H*/M
REC10-xx3.3SZ/H*/M
REC10-xx05SZ/H*/M
REC10-xx12SZ/H*/M
REC10-xx15SZ/H*/M
REC10-xx05DZ/H*/M
REC10-xx12DZ/H*/M
REC10-xx15DZ/H*/M
Input
Voltage
(VDC)
9-18, 18-36, 36-75
9-18, 18-36, 36-75
9-18, 18-36, 36-75
9-18, 18-36, 36-75
9-18, 18-36, 36-75
9-18, 18-36, 36-75
9-18, 18-36, 36-75
9-36, 18-75
9-36, 18-75
9-36, 18-75
9-36, 18-75
9-36, 18-75
9-36, 18-75
9-36, 18-75
Output
Voltage
(VDC)
3.3
5
12
15
±5
±12
±15
3.3
5
12
15
±5
±12
±15
Output
Current
(mA)
2000
2000
833
667
±1000
±416
±333
2000
2000
833
667
±1000
±416
±333
Efficiency Max. Cap.
(typ.)
Load
(%)
83-84
86-87
85-86
85-86
82-83
85-86
85-86
82
86
85
86
82
85
86
2200µF
2200µF
2200µF
2200µF
±1000µF
±1000µF
±1000µF
2200µF
2200µF
2200µF
2200µF
±1000µF
±1000µF
±1000µF
10 Watt
2” x 1”
Single
&
Dual
Output
2011/65/EU
6/6
RoHS
E-224736
EN-60950-1 Certified
EN-60601-1 Certified
UL-60950-1 Certified
REC10/M
* Standard is /H2 for 2kVDC isolation,
use /H3 for 3kVDC Isolation
2:1
xx = 9-18Vin = 12,
xx = 18-36Vin = 24,
xx = 36-75Vin = 48
4:1
xx = 9-36Vin = 24,
xx = 18-75Vin = 48
Specifications
(
measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Input Voltage Range
Input Filter
Output Voltage Accuracy (the Output 3.3V is ±1.2% max.)
Line Voltage Regulation
Load Voltage Regulation
(25% to 100% full load )
Single
Dual
2:1 or 4:1
PI Network
±1.0% max.
±0.3% max.
±0.5% max.
±1.2% max.
±5% max.
100mVp-p max.
25ms typ.
300kHz typ.
see Selection Guide
0%
12V Input
24V Input
48V Input
36VDC
50VDC
100VDC
continued on next page
E-166
REV: 0/2015
Refer to Application Notes
www.recom-power.com
**Any data referred to in this datasheet are of indicative nature
and based on our practical experience only. For further details,
please refer to our Application Notes.
Cross Regulation (100%: 25% to 100% full load )
Output Ripple and Noise (with 100n output capacitor and 20MHz BW)
Start-up time (Nom. Vin at 100% Load)
Operating Frequency (Full Load)
Efficiency (Nom. Vin at 100% Load)
Minimum Load
Input Surge Voltage (100ms max.)
Questions about the read and write operations of 24CXXX series EEPROM?
If this thing is read and written continuously, must it be read and written in pages? For example, there is a uchar[8] and I start writing from address 0x0d, then where will uchar[3-7] be written? A: ...
280440616 Embedded System
Please advise on the details of wireless module CC1100 transmission and reception
I have a question for you guys: I am debugging cc1100 recently. It works, but I have to delay about 30ms on the sending end to receive the data correctly (displayed on the PC through the serial port)....
hejie82810 Embedded System
Search is a technical job....It's hard to pass....
Every time I need to find some information, I have to spend a lot of effort, it's so strange. Every time my boss asks me to do something, he always asks me to google it first, and tells me there are t...
shuangshumei Talking
A heating unit power supply solution with constant and adjustable output power based on TPS61022
The TPS61022 constant and adjustable output power heating unit power supply solution introduced mainly includes a lithium battery, a boost circuit ( TPS61022 ) and a heating resistor (2 Ω). This solut...
qwqwqw2088 Analogue and Mixed Signal
[Help] What does _WrL3Data(0xf2,0); mean in I2S?
,0); // 1100 0010: DATA0, Extended addr(010) _WrL3Data(0xf2,0); // 111 111 01: DATA0, MS=9dB, Ch1=on Ch2=on _WrL3Data(0xc4,0); // 1100 0010: DATA0, Extended addr(010) _WrL3Data(0xE0,0); // 111 111 01:...
核桃佳子 Embedded System
Does anyone have the Chinese manuals for DM642's SPRU610, 629, etc. available for download?
Haha, I saw that many people translated the TMS320DM642 chip manual. Well, haha. I still think it is more detailed to read the SPRU manuals. Because time is tight now, I want to ask if you have their ...
cncdrawer Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1032  2733  948  431  691  21  56  20  9  14 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号