RSD-300C-24

Description
DC/DC CONVERTER 24V 300W
CategoryPower/power management   
File Size317KB,10 Pages
ManufacturerMEAN WELL
Websitehttp://www.meanwell.com
Environmental Compliance
Download Datasheet Parametric View All

RSD-300C-24 Online Shopping

Suppliers Part Number Price MOQ In stock  
RSD-300C-24 - - View Buy Now

RSD-300C-24 Overview

DC/DC CONVERTER 24V 300W

RSD-300C-24 Parametric

Parameter NameAttribute value
typeclosed
Voltage - Input (minimum)33.6V
Voltage - input (maximum)62.4V
Number of outputs1
Voltage - Output 124V
Voltage - Output 2-
Voltage - Output 3-
Voltage - Output 4-
Current - Output (maximum)12.5A
Power (W)300W
Voltage - Isolation4000V
applicationITE (Commercial), Railway
efficiency91.5%
Operating temperature-40°C ~ 70°C (with derating)
Installation typeBase installation
size/dimensions8.50" long x 3.80" wide x 1.57" high (216.0mm x 96.5mm x 40.0mm)
ApprovalCE
300W Railway Single Output DC-DC Converter
RSD-300
series
Features :
Compliance to EN50155 and EN45545-2 railway standard
2:1 wide input range
Protections: Short circuit / Overload / Over voltage / Over temperature
/ Input reverse polarity
4000VDC I/O isolation
Cooling by free air convection
Half encapsulated
Built-in constant current limiting circuit
1U low profile 40mm
All using 105
long life electrolytic capacitors
LED indicator for power on
100% full load burn-in test
3 years warranty
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
RSD-300B-5
5V
42A
0 ~ 42A
210W
RSD-300B-12 RSD-300B-24 RSD-300B-48 RSD-300C-5
12V
22.5A
0 ~ 22.5A
270W
120mVp-p
±2.0%
±0.3%
±1.0%
24V
11.3A
0 ~ 11.3A
271.2W
150mVp-p
±2.0%
±0.2%
±1.0%
48V
5.7A
0 ~ 5.7A
273.6W
180mVp-p
±2.0%
±0.5%
±1.0%
5V
42A
0 ~ 42A
210W
100mVp-p
±2.0%
±0.5%
±1.0%
RSD-300C-12 RSD-300C-24 RSD-300C-48
12V
25A
0 ~ 25A
300W
120mVp-p
±2.0%
±0.3%
±1.0%
24V
12.5A
0 ~ 12.5A
300W
150mVp-p
±2.0%
±0.2%
±1.0%
48V
6.3A
0 ~ 6.3A
302.4W
180mVp-p
±2.0%
±0.5%
±1.0%
RIPPLE & NOISE (max.)
Note.2
100mVp-p
VOLTAGE TOLERANCE
Note.3
±2.0%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE
RANGE
CONTINUOUS
1 SEC.
EFFICIENCY (Typ.)
DC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
OVERLOAD
±0.5%
±1.0%
800ms, 50ms at full load
B/C- type comply with S1 level @ full load, comply with S2 level @ 70% load
16.8 ~ 31.2VDC
14.4 ~ 33.6VDC
89%
9.7A/24V
45A/24VDC
89.5%
14.6A/24V
90%
14.6A/24V
91.5%
14.6A/24V
33.6 ~ 62.4VDC
28.8 ~ 67.2VDC
90.5%
4.8A/48V
45A/48VDC
91%
7.2A/48V
91.5%
7.2A/48V
92%
7.2A/48V
INPUT
105 ~ 135% rated output power
Protection type :
Constant current limiting, recovers automatically after fault condition is removed
5.75 ~ 7V
13.8 ~ 16.2V
27.6 ~ 32.4V
55.2 ~ 64.8V
5.75 ~ 7V
13.8 ~ 16.2V
27.6 ~ 32.4V
55.2 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after temperature goes down
-40 ~ +55
(no derating) ; +70
@ 60% load by free air convection ; +70
no derating with external base plate, TX class compliance
5 ~ 95% RH non-condensing
-40 ~ +85
, 5 ~ 95% RH non-condensing
±
0.03%/
(0 ~ 55
)
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373
IEC60950-1(LVD)
,
EAC TP TC 004 approved
I/P-O/P:4KVDC
I/P-FG:2.5KVDC
O/P-FG:2.5KVDC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
/ 70% RH
Compliance to EN55032 (CISPR32) Conduction Emission: Class A, Radiation Emission: Class B,
EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8, light industry level, criteria A,
EAC TP TC 020
EN50155 / IEC60571 including IEC61373 for shock & vibration, EN50121-3-2 for EMC
;
EN45545-2 for fire protection
130.7K hrs min.
MIL-HDBK-217F (25
)
216*96.5*40mm (L*W*H)
1.19Kg ; 12pcs/15.3Kg/1.12CUFT
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY &
EMC
(Note 5)
ISOLATION RESISTANCE
EMC EMISSION
EMC IMMUNITY
RAILWAY STANDARD
MTBF
OTHERS
DIMENSION
PACKING
NOTE
1. All parameters NOT specially mentioned are measured at 24,48VDC input, rated load and 25
of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Strongly recommended that external output capacitance should not exceed 5000uF.
(Only
for: RSD-300-5 / -12)
5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to
perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
6. The ambient temperature derating of 3.5
/1000m with fanless models and of 5
/1000m with fan models for operating altitude higher than 2000m(6500ft).
File Name:RSD-300-SPEC 2018-01-15

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1035  2754  2509  2295  1092  21  56  51  47  22 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号