EEWORLDEEWORLDEEWORLD

Part Number

Search

RNM-153.3S/HP

Description
DC DC CONVERTER 3.3V 1W
CategoryPower/power management   
File Size115KB,3 Pages
ManufacturerRECOM Power GmbH
Websitehttps://www.recom-power.com/
Environmental Compliance
Download Datasheet Parametric View All

RNM-153.3S/HP Overview

DC DC CONVERTER 3.3V 1W

RNM-153.3S/HP Parametric

Parameter NameAttribute value
typeisolation module
Number of outputs1
Voltage - Input (minimum)13.5V
Voltage - input (maximum)16.5V
Voltage - Output 13.3V
Voltage - Output 2-
Voltage - Output 3-
Current - Output (maximum)303mA
Power (W)1W
Voltage - Isolation2kV
applicationITE (Business)
characteristicSCP
Operating temperature-40°C ~ 85°C
efficiency75%
Installation typeThrough hole
Package/casing6-DIP module, 4 leads
size/dimensions0.33" long x 0.33" wide x 0.27" high (8.3mm x 8.3mm x 6.8mm)
Features
Unregulated
Converters
Ultra-compact - only 8.3 x 8.3 x 6.8mm
1kVDC or 2KVDC Isolation
No External Components Required
Optional Continuous Short Circuit Protected
Fully Encapsulated
UL and EN Certified, CB Report
Efficiency to 84%
ECONOLINE
DC/DC-Converter
with 3 year Warranty
Description
The RNM series DC/DC converters are ultra-compact isolated single output converters for
applications where board space is at a premium. Despite their small size, the converters are
fully featured with a full industrial operating temperature range of -40°C to +85°C without
derating (+100°C with derating), 1kVDC or 2kVDC isolation and optional short circuit
protection. The converters are also UL-60950 and EN-60950 certified and have a CB Report.
Selection Guide
Part
Number
DIP6
RNM-xx3.3S
RNM-xx05S
RNM-xx09S
RNM-xx12S
RNM-xx15S
Input
Voltage
(VDC)
3.3, 5, 12, 15
3.3, 5, 12, 15
3.3, 5, 12, 15
3.3, 5, 12, 15
3.3, 5, 12, 15
Output
Voltage
(VDC)
3.3
5
9
12
15
Output
Current
(mA)
303
200
111
83
66
Efficiency
(%)
75
70-78
70-78
76-78
78-84
Max.
Capacitive
Load
(1)
2200μF
1000μF
1000μF
470μF
470μF
1 Watt
DIP6
Single Output
(2kV)
(H)
(H)
(H)
(H)
(H)
x = Input Voltage (other input and output voltage combinations available on request)
* add Suffix “P” for Continuous Short Circuit Protection, e.g.
RNM-0505S/P, RNM-0505S/HP
RoHS
Specifications
(
measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Input Voltage Range
Output Voltage Accuracy
Line Voltage Regulation
Load Voltage Regulation
(10% to 100% full load)
Output Ripple and Noise (20MHz limited)
Operating Frequency
Efficiency at Full Load
Minimum Load = 0%
Isolation Voltage
Isolation Voltage
Rated Working Voltage
Isolation Capacitance
Isolation Resistance
Short Circuit Protection
P-Suffix
Operating Temperature Range (free air convection)
Storage Temperature Range
Relative Humidity
Package Weight
Packing Quantity
H-Suffix
H-Suffix
(tested for 1 second)
(rated for 1 minute**)
(tested for 1 second)
(rated for 1 minute**)
3.3V output type
5V output type
9V, 12V and 15V output types
±10%
±5%
1.2%/1% of Vin typ.
20% max.
15% max.
10% max.
100mVp-p max.
50kHz min. / 100kHz typ. / 105kHz max.
70% min.
Specifications valid for 10% minimum load only.
1000VDC
500VAC / 60Hz
2000VDC
1000VAC / 60Hz
20pF min. / 75pF max.
10 GΩ min.
1 Second
Output Power (%)
100
80
60
40
30
20
0
2011/65/EU
6/6
E358085
UL-60950-1 Certified
EN-60950-1 Certified
RNM
Derating-Graph
(Ambient Temperature)
Continuous
-40°C to +85°C (see Graph)
-55°C to +125°C
95% RH
1.1g
60 pcs per Tube
continued on next page
Safe Operating Area
85
Operating Temperature °C
-40
0
50
100
150
**Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer
to our Application Notes.
Refer to Application Notes
E-32
REV: 0/2015
www.recom-power.com
What is the RSSI range? How to set the threshold?
I use zstack to read the RSSI value. I don't know what is the normal RSSI value between two nodes? What is the threshold value to judge that the channel noise is too large and not suitable for transmi...
caimengyi RF/Wirelessly
It seems like there are only a few days left for the holiday. How are everyone's holiday study opportunities going?
In a blink of an eye, we are all living in the Year of the Dragon. May everyone have a happy Year of the Dragon and may you all travel the world with dragons! I remember that I posted a post before th...
奔跑的蜗牛 FPGA/CPLD
WinCE5.0 in VS2005 (C#) RasDial after GPRS dial-up is successful, the IP is automatically obtained, but the socket connection cannot be used
1. Use WinCE5.0 operating system to establish a dial-up connection named "GPRS". The GPRS module uses the serial port to connect to the WINCE motherboard. 2. VS2005 uses C# to encapsulate the Ras API ...
netthief Embedded System
Capacitor Application in Power Supply Design
...
追梦1988 Analog electronics
Is there a microcontroller that can convert a USB port into a parallel port?
As the title says, please share your experience, thank you! ! ! !...
yangguo MCU
Power supply stabilization
I want to get 5V and 15V voltages at the same time. This circuit is theoretically possible, but I don't know if it will work when connected into a practical circuit. If you have made a power supply, c...
mxwjx Power technology

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2858  1863  2115  2537  675  58  38  43  52  14 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号