REVISIONS
REV
-
A
DESCRIPTION
ISSUE 1
REVISIED OPERATING TEMP ON PAGE 4.
OVP FOR 48V ON PAGE 2.
REMOTE ON/OFF ON PAGE 2.
CHANGED CN4 ON PAGE 5
CHANGED D (MODELS – H & J ON PAGE 4
REVISED NOTE D. FOR –H &J: SWITCHED WITH & WITHOUT COVER
TEMPS
DATE
07/02/02
ISSUED BY
/
RJ
B
C
D
07/12/02
11/20/03
06/26/06
RJ
JC
YS
FILE NAME:
CAD1:MSWORD:PA211242.DOC
TITLE:
SCALE:
NONE
REV:
D
SH
1
OF
7
DOCUMENT NUMBER:
OVS-U (UNIVERSAL INPUT) SERIES SPECIFICATION
PREPARED BY:
P-A2-11242
K. BRENNAN
M. PITCHAI
Y. SEKIGUCHI
06/26/06
06/26/06
06/26/06
ENGINEERING:
APPROVED:
43352 BUSINESS PARK DRIVE • TEMECULA • CA • 92590
TEL: (951) 699-1270 • FAX: 9516769482
PROPRIETARY NOTICE: THIS DRAWING PRINT OR DOCUMENT AND SUBJECT MATTER DISCLOSED HEREIN ARE PROPRIETARY ITEMS TO WHICH
TAMURA RETAINS THE EXCLUSIVE RIGHT OF DISSEMINATION, REPRODUCTION, MANUFACTURE AND SALE. THIS DRAWING, PRINT OR DOCUMENT IS
SUBMITTED IN CONFIDENCE FOR CONSIDERATION BY THE RECIPIENT ALONE UNLESS PERMISSION FOR FURTHER DISCLOSURE IS EXPRESSLY
GRANTED IN WRITING.
A. Electrical Specifications
(1) AC Input Voltage Rating
AC100 - 230V, 50/60Hz (47 - 63Hz)
AC90 - 264V ------E Series
AC90 - 132VAC / AC180 - 264V ------F to J Series
(Automatic voltage selection)
DC115 - 372V ------E Series
DC230 - 372V ------F to J Series with JW1 open
35A MAX for E Series at nominal line (115/230V) cold start
30A MAX for F to J Series at nominal line (115/230V) cold start
± 10% MIN
24V output: 22.8V to 29.2V
± 0.5% MAX under specified input range
± 0.5% MAX from no load to full rated load
3/5 - 15V output 75mVp-p MAX
24V output
120mVp-p MAX
28, 48V output
240mVp-p MAX
DC Input Voltage Range
(2) Input Surge Current
(3) DC Output Adjustment Range
(4) Line Regulation
(5) Load Regulation
(6) Output Ripple and Noise
DC to 20MHz BW
(7) Hold-up Time
(8) Output Transient Response
20msec MIN under nominal line and rated load
1msec MAX over ±2% of rated voltage
under 50 - 100% load change
100msec MAX, from 10% to 90% of rated output voltage
70% MIN at nominal line and rated load
120% TYP of rated load, fold-back limiting type
3V output
5V output
12V output
15V output
24/28V output
48V output
3.8 - 4.6V
5.7 - 6.7V
14.25 - 15.75V
17.25 - 18.75V
31.0 - 34.5V
54.0 - 62.0V
(9) Output Voltage Rise Time
(10) Efficiency
(11) Overload Protection
(12) OverVoltage Protection
(13) Leakage Current
(14) Overshoot
(15) Output Voltage Stability
(16) Temperature Coefficient
(17) Remote/Local Sensing
(18) Remote ON/OFF Control
0.75mA rms MAX
No overshoot during turn ON/OFF
± 0.1% MAX for 8 hours after 20 minute warm-up
±0.03% per deg. C MAX
Built-in
Built-in F, G, H and J Series, 300uA MIN
< 1V for inhibit, > 4.5V (or open) for ON
FILE NAME:
CAD1:MSWORD:PA211242.DOC
SCALE:
NONE
TITLE:
REV:
D
DATE:
06/26/06
SH
2
OF
7
OVS-U (UNIVERSAL INPUT) SERIES
43352 BUSINESS PARK DRIVE • TEMECULA • CA •
92590
TEL: (951) 699-1270 • FAX: 9516769482
DOCUMENT NUMBER:
P-A2-11242
19) AC Power Fail Signal
Built-in on 5V output models only, other voltages optional
Power Good Logic “0”
Power Fail Logic “1”, 5msec MIN pulse width, output 4.5V ±5%
Current sharing capability available by using CS terminal and external circuit
Meets IEEE587 C62.41 test method with no damage to power supply
AC 3KV (Input - Output), AC 1.5KV (Input - Chassis ground)
50Mohm MIN DC500V (Input - Output)
20) Current Sharing
21) Surge Voltage Test
22) Withstand Voltage
23) Insulation Resistance
24) Part Number Description
Model No.
Series Name
Output voltage
OVS -
- U
U: No cover (Standard
)
UC: With cover (Option)
Case size
CASE SIZE
E
MODEL
OVS-5E-UC
OVS-12E-UC
OVS-15E-UC
OVS-24E-UC
OVS-48E-UC
OVS-5F-UC
OVS-12F-UC
OVS-15F-UC
OVS-24F-UC
OVS-48F-UC
OVS-5G-UC
OVS-12G-UC
OVS-15G-UC
OVS-24G-UC
OVS-48G-UC
OVS-5H-UC
OVS-12H-UC
OVS-15H-UC
OVS-24H-UC
OVS-48H-UC
OVS-5J-UC
OVS-12J-UC
OVS-15J-UC
OVS-24J-UC
OVS-48J-UC
* INDICATES A DUAL RATING
VOLTS
5
12
15
24
48
3.2 *
5*
12
15
24 *
28 *
48
3.2 *
5*
12
15
24 *
28 *
48
3.2 *
5*
12
15
24 *
28 *
48
3.2 *
5*
12
15
24 *
28 *
48
AMPS
0-10
0-5
0-4
0-2.5
0-1.2
2-20 *
0-20 *
0-10
0-8
0-5 *
0-3.8 *
0-2.3
3-30 *
0-30 *
0-15
0-12
0-8 *
0-6 *
0-3.7
4.5-45 *
0-45 *
0-22
0-18
0-12 *
0-9.2 *
0-5.5
6-60 *
0-60 *
0-30
0-25
0-16 *
0-12.2 *
0-7.3
F
G
H
J
FILE NAME:
CAD1:MSWORD:PA211242.DOC
SCALE:
NONE
TITLE:
REV:
D
DATE:
06/26/06
SH
3
OF
7
OVS-U (UNIVERSAL INPUT) SERIES
43352 BUSINESS PARK DRIVE • TEMECULA • CA • 92590
TEL: (951) 699-1270 • FAX: 9516769482
DOCUMENT NUMBER:
P-A2-11242
Note 1. Output ripple and noise to be measured with a 4.7uF +0.1 uF film or ceramic capacitor measured at points A as shown below.
Note 2. Output voltage to be measured at output terminals, Points B as shown below.
Note 3. OVS-5*-U has a dual rating of 3.2V and 5V. The unit is shipped from the factory set to 5V.
To obtain 3.2V, the unit must be modified according to the instructions.
Note 4. OVS-24*-U has a dual rating of 24V and 28V. The unit is shipped from the factory set to 24V.
To obtain 28V, customer must readjust the output voltage potentiometer.
POINT B
OUTPUT
POINT A
Measuring Points
+
POWER SUPPLY
4.7uF
+
0.1 uF
LOAD
-
OUTPUT
POINT B
POINT A
A: Output Ripple and Noise
B: Output Voltage
Capacitors
4.7uF: Low ESR Electrolytic
0.1uF: Polyester film or ceramic
150mm +/-10mm (5.9” +/-0.4”)
B. Safety
Meets UL1950, C22.2 No. 234, EN60950, VDE0805
C. EMI
Meets FCC20780 Part 15J Class B
E, F Series
Class A
G, H, J Series
VDE 0871 Class B
E, F Series
Class A
G, H, J Series
VCC1 Class 2
E, F Series
Class 1
G, H, J Series
Note 1. Models OVS-48E-UC and -48F-UC meet Class A for FCC and VDE and meet Class 1 with VCC1
D. Environmental
(1) Operating Temperature
MODELS –E, F & G:
0 to +40 deg. C with cover, 0 to +50 deg. C without cover*
In either case, the temperature at the center portion on the side of the
chassis should be +60 deg. C MAX.
For operation above +40 with cover (+50 deg. C without cover) derate
linearly to 50% load at +55 deg. C with cover (+65 deg. C without cover).
In either case, the temperature at the center portion on the side of the chassis
should be +70 deg. C MAX.
* Ambient temperature to be measured at 1” above the main transformer.
MODELS –H & J:
0 to +40 deg. C with cover, 0 to +50 deg. C without cover*
In either case, the temperature at the center portion on the side of the
chassis should be +60 deg. C MAX.
For operation above +40 deg. C without cover (+50 deg. C with cover)
derate linearly to 50% load at +55 deg. C without cover (+65 deg. C with cover).
In either case, the temperature at the center portion on the side of the chassis
should be +70 deg. C MAX.
*Ambient temperature to be measured at 1” above the main transformer
(2) Storage Temperature
-20 to +85 deg. C
FILE NAME:
CAD1:MSWORD:PA211242.DOC
SCALE:
NONE
TITLE:
REV:
D
DATE:
06/26/06
SH
4
OF
7
OVS-U (UNIVERSAL OUTPUT) SERIES
43352 BUSINESS PARK DRIVE • TEMECULA • CA • 92590
TEL: (951) 699-1270 FAX: 9516769482
DOCUMENT NUMBER:
P-A2-11242
(3) Operating Humidity
(4) Storage Humidity
(5) Vibration
(6) Shock
10 - 90% RH, non condensing
10 - 95%, non condensing
10 - 55Hz, 2G (All axis, 1 hour)
20msec, 20G (All axis, 3X ea.)
E. Power Factor Correction
Use Tamura Part Number PFC-500 as an external active filter power supply for OVS-E through J Series
F. Input and Output terminals
Input
Output
*I/O Terminal Screws: M4
CN1 (Remote sense) Pin Assignment
#1 pin
+Sense
#2 pin
-Sense
CN2 (Input / Output Signal) Pin Assignment
#1 pin
CS (Current sharing, external circuit required)
#2 pin
AC Power Fail signal output (+5V only, other voltages optional)
#3 pin
SG (Signal Ground)
#4 pin
Remote ON/OFF (not available on E Series)
CN3, CN4 Jumper Tip Position
CN3
+OUT
CN4
-OUT
#1
Front side of
Power Supply
Short for Remote Sensing (Use CN1)
Short for Local Sensing (CN1 not used)
CN1 Part No:
Mating Part No:
5273-02A/Molex
5195-02 or 5239-02/Molex
FILE NAME:
CAD1:MSWORD:PA2112421.DOC
SCALE:
NONE
TITLE:
REV:
D
DATE:
06/26/06
SH
5
OF
7
OVS-U (UNIVERSAL OUTPUT) SERIES SPECIFICATION
43352 BUSINESS PARK DRIVE TEMECULA CA 92590
TEL: (951) 699-1270 FAX: 9516769482
DOCUMENT NUMBER:
P-A2-11242