tfs469.doc
version 2.0
06/98
______________________________________________________________________________________________________
VI
TELEFILTER
Specification
TFS 469 - 1/4
______________________________________________________________________________________________________
Measurement condition
Ambient temperature:
Input power level:
Terminating impedance:
23
°C
0 dBm
270
Ω
|| -1pF
Construction and pin connection
see page 2
Stability characteristics and packing
see page 3
Air reflow temperature conditions
see page 4
Characteristics
Remark:
Reference level for the relative attenuation arel is the minimum of the pass band attenuation amin. The minimum of the pass
band attenuation amin is defined as the insertion loss ae. The nominal frequency is fixed on 469.99 MHz. The centre frequency
f0 is the arithmetic mean value of the upper and lower frequencies at the 3 dB filter attenuation level relative to the insertion
loss ae.
D a t a
______________________________________________________________________________________________________
Insertion loss
3
dB
max.
5 dB
ae = amin
(Reference level)
______________________________________________________________________________________________________
Nominal frequency
f
N
-
469.99 MHz
______________________________________________________________________________________________________
Centre frequency
f
0
469,99 MHz
-
______________________________________________________________________________________________________
3 dB - bandwidth
280
kHz
-
BW
______________________________________________________________________________________________________
Usable signal bandwidth
-
min. f
N
±
10 kHz
______________________________________________________________________________________________________
Relative attenuation
arel
f
N
+ 910 kHz
min. 52
dB
min. 40
dB
f
N
±
0,7 MHz ... f
N
±
10 MHz
______________________________________________________________________________________________________
Temperature coefficient of frequency
-0,036 ppm/K
2
-
TC
f
______________________________________________________________________________________________________
Frequency inversion temperature
+ 25 °C
______________________________________________________________________________________________________
Operating temperature range
- 10°C ... + 50°C
______________________________________________________________________________________________________
typ. value
Variation / Limitation
generated:
checked / approved:
______________________________________________________________________________________________________
VI TELEFILTER
Vectron Technologies, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: tft@telefilter.com
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs469.doc
version 2.0
06/98
______________________________________________________________________________________________________
VI
TELEFILTER
Specification
TFS 469 - 2/4
______________________________________________________________________________________________________
Construction and pin connection
(All dimensions in mm)
8
9
7
6
5
4
10
TFS 469
tft
K6
1
2
3
1
2
3
4
5
6
7
8
9
10
Ground
Ground
Ground
Ground
Output
Ground
Ground
Ground
Ground
Input
50
Ω
test circuit 1
L1
10
5
L2
C1
C2
1,2,3,4
6,7,8,9
50
Ω
test circuit 2
C1
10
5
C2
L1
L2
1,2,3,4
6,7,8,9
______________________________________________________________________________________________________
VI TELEFILTER
Vectron Technologies, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: tft@telefilter.com
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs469.doc
version 2.0
06/98
______________________________________________________________________________________________________
VI
TELEFILTER
Specification
TFS 469 - 3/4
______________________________________________________________________________________________________
Stability Characteristics
After the following tests the filter shall meet the whole specification:
1. Shock:
2. Vibration:
3. Damp heat:
(steady state)
4. Resistance to
solder heat (reflow):
100g, 18 ms, half sine wave, 3 shocks each plane;
DIN IEC 68 T2 - 27
10 Hz to 500 Hz, 0,075 mm or 1g respectively, 1 octave per min, 10 cycles per plan, 3 plans;
DIN IEC 68 T2 - 6
90 % to 95 % rel. humidity, 40 °C, 10 days;
DIN IEC 68 - 2 - 3
max. 2 times reflow process;
for temperature conditions refer to the attached "Air reflow temperature conditions" on sheet 4;
Packing
Tape & Reel:
IEC 286 - 3, with exception of value for N and minimum bending radius;
tape type
II,
embossed carrier tape with top cover tape on the upper side;
max. pieces of filters per reel: 3400
Tape (all dimensions in mm)
W
:
16
± 0,3
D
o
P
o
P
2
EMBOSSED CARRIER TAPE
Po
:
Do
:
D1
:
E
:
F
:
G (min) :
P2
:
P1
:
D1(min) :
Ao
:
Bo
:
4
± 0,1
1,5 + 0,5
1,5 + 0,5
1,75 ± 0,1
7,5 ± 0,1
0,75
2 ± 0,05
8 ± 0,1
1,5
5,3 ± 0,1
9,7 ± 0,1
E
A
o
F
W
D
1
13,4
± 0,1
B
o
G
P
1
COVER TAPE
W 2
Reel (all dimensions in mm):
A
W1
W2 (max) :
N (min)
C
:
:
:
:
330
16,4 +2
22,4
>= 90
C
A
N
13
± 0,25
W 1
The minimum bending radius is 45 mm. The mounting surface of the filters faces the bottom side of the embossed carrier tape.
The marking of the filters is able to read if the view is directed on the upper side of the carrier tape with the sprocket holes on
the right side of the tape.
______________________________________________________________________________________________________
VI TELEFILTER
Vectron Technologies, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: tft@telefilter.com
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
tfs469.doc
version 2.0
06/98
______________________________________________________________________________________________________
VI
TELEFILTER
Specification
TFS 469 - 4/4
______________________________________________________________________________________________________
Air reflow temperature conditions
1st and 2nd air reflow profile
Name:
Temperature:
Time:
pre-heating periods
150 °C - 170 °C
60 sec. - 90 sec.
main-heating periods
over 200 °C
20 sec. - 25 sec.
peak temperature
255 °C ± 5 °C
Chip-mount air reflow profile
260
240
220
200
180
temperature / °C
160
140
120
100
80
60
40
20
0
0
20
40
60
80
100
120
time / sec.
140
160
180
200
220
240
Table for temperature vs. time during the air reflow process
Tolerance of temperatures: ± 5 °C
time / sec.
0
10
20
30
40
50
60
70
80
90
100
110
120
130
temperature / °C
23
34
46
60
80
103
121
134
143
150
154
156
158
159
time / sec.
140
150
160
170
180
190
195
200
205
210
215
220
230
240
temperature / °C
160
161
164
170
180
205
230
255
230
205
180
165
140
120
______________________________________________________________________________________________________
VI TELEFILTER
Vectron Technologies, Inc.
Potsdamer Straße 18
267 Lowell Road
D 14 513 TELTOW / Germany
Hudson, NH 03051 / USA
Tel: (+49) 3328 4784-52 / Fax: (+49) 3328 4784-30
Tel: (603) 598-0070 Fax: (603) 598-0075
E-Mail: tft@telefilter.com
E-Mail: vti@vtinh.com
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
VI TELEFILTER reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.