EEWORLDEEWORLDEEWORLD

Part Number

Search

AEM60US48

Description
60 WATTS
CategoryPower/power management   
File Size134KB,2 Pages
ManufacturerXP Power
Websitehttps://www.xppower.com/
Download Datasheet Parametric Compare View All

AEM60US48 Online Shopping

Suppliers Part Number Price MOQ In stock  
AEM60US48 - - View Buy Now

AEM60US48 Overview

60 WATTS

AEM60US48 Parametric

Parameter NameAttribute value
Use areainternationality
formDesktop (Class II)
input typeCable (sold separately)
Voltage - input80 ~ 264 VAC
Voltage - Output48V
Current - Output (maximum)1.25A
Power (W)60W
No-load power consumption-
polarizationpositive center
applicationMedical type
efficiency85%
Operating temperature0°C ~ 60°C
Output connectorRound tube plug, 2.5mm round tube plug x 5.5mm outer diameter x 12.0mm
size/dimensions5.20" long x 2.28" wide x 1.20" high (132.1mm x 58.0mm x 30.5mm)
ApprovalCE
input connectorIEC 320-C8
Wire length48"(1.22m)
AC DC
60 Watts
AEM60 Series
Worldwide Medical Approvals
4000 VAC Isolation
Class II Construction
xppower.com
CEC 2008 & EISA 2007 Compliant 12 V
Single Outputs from 5 V to 48 V
High Efficiency
3 Year Warranty
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Input Protection
No Load Input Power
• 80-264 VAC, derate output power 5%
<90 VAC and 10% <85 VAC
• 47-63 Hz
• 1.5 A rms max
• 80 A max at 240 VAC
• Fitted with a T2 A/250 VAC fuse in live line
• <0.5 W for ≥12 V output
General
Efficiency
Isolation
Switching Frequency
Power Density
MTBF
85%, see note 5
4000 VAC Input to Output
100 kHz typical
4.2 W/Inch
3
300 kHrs to MIL-HDBK-217F
at 25 ˚C, GB
Environmental
Operating Temperature
• 0 °C to +60 °C, derate linearly from 100%
load at +40 °C to 50% load at +60 °C
Cooling
• Convection-cooled
Operating Humidity
• 15-95% non-condensing
Storage Temperature
• -20 °C to +85 °C
Operating Altitude
• 3000 m
Vibration
• 5-500 Hz at 3 g for 10 mins on each axis
Shock
• 30 g with 18 ms half sine wave,
3 times on each axis
Output
Output Voltage
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
Line Regulation
Load Regulation
Transient Response
See table
See table
No mimimum load required
3 s max
3 ms
8 ms minimum at 115 VAC
±1%
See table
5% max deviation recovering to within 1%
within 500 µs for 50% load change
1% max, 20 MHz bandwidth (see note 2)
See table
120-150%, trip & restart (hiccup mode),
auto-recovery
Continuous
±0.05%/°C
EMC & Safety
Emissions
Harmonic Currents
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
Safety Approvals
EN55011 Level B conducted & radiated
EN61000-3-2, class A
EN61000-3-3
EN61000-4-2 Level 3, Perf Criteria A
EN61000-4-3 Level 2, Perf Criteria A
EN61000-4-4, Level 3, Perf Criteria A
EN61000-4-5 Level 3, Perf Criteria A
EN61000-4-6 Level 3, Perf Criteria A
EN61000-4-11, 30% 10 ms, 60% 100 ms,
100% 5000 ms Perf Criteria A, B, B
• UL60601-1, EN60601-1, IEC60601-1,
CE Mark
Ripple & Noise
Overvoltage Protection
Overload Protection
Short Circuit Protection
Temperature
Coefficient

AEM60US48 Related Products

AEM60US48 AEM60US36 AEM60US12 AEM60US19 AEM60US24 AEM60US18 AEM60US15 AEM60US05 AEM60
Description 60 WATTS Worldwide Medical Approvals Worldwide Medical Approvals Worldwide Medical Approvals Worldwide Medical Approvals Worldwide Medical Approvals Worldwide Medical Approvals Worldwide Medical Approvals Worldwide Medical Approvals

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1756  693  2715  2649  204  36  14  55  54  5 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号