LES DC-DC Series Data Sheet
Single-Output, 15 Watts
Features
•
•
•
•
•
Description
LES DC-DC converters provide up to 15 watts of output
power in an industry-standard package and footprint. With
a maximum case temperature of 100 °C, the LES is well
suited for the most demanding telecom, networking, and
industrial applications. The LES features 1500 VDC
isolation, short circuit protection, and six-sided shielding.
The LES is available with optional enable and voltage trim
pins. Please see the IAD Series for dual output
applications.
Technical Specifications
Input
Voltage Range
24 VDC Nominal
48 VDC Nominal
Reflected Ripple
18 - 36 VDC
36 - 75 VDC
50 mA
RoHS lead-solder
exemption compliant
Industry-standard package
Industry-standard pinout
100 °C case operation
Short-circuit protection
•
•
•
•
24 V and 48 V inputs
Input Pi filter and
6-sided shielding
Regulated outputs
1500 V isolation
Efficiency vs. Load (24V Input)
85
80
75
EFFICIENCY %
70
65
60
55
50
45
10
20
30
40
50
LES010YE-A
EFF. (18v)
EFF. (24v)
EFF. (36v)
60
70
80
90
100
LOAD %
Output
Setpoint Accuracy
Line Regulation Vin Min. - Vin Max., Iout Rated
Load Regulation Iout Min. - Iout Max., Vin Nom.
Minimum Output Current
Dynamic Regulation, Loadstep
Pk Deviation
Settling Time
Voltage Trim Range
Short Circuit / Overcurrent Protection
Current Limit Threshold Range, % of Iout Rated
Short Circuit Current Max.
(12Vout & 15Vout : 4.0A when Vout= 0.25V)
Ovp Trip Range
Ovp Type
±1%
0.2%
Vout
0.5% Vout
10% Iout Rated
25% Iout
2% Vout
500 ms
±10%
Shutdown / Hiccup
110 - 150%
200% Iout
115 -140% Vout Nom.
Second Control Loop
85
80
75
EFFICIENCY %
Efficiency vs. Load (48V Input)
70
65
60
55
50
10
20
30
40
50
60
70
80
90
100
LOAD %
LES010ZE
LES015ZG
Notes
† MTBF predictions may vary slightly from model to model.
Specifications typically at 25 °C, normal line, and full load,
unless otherwise stated.
Soldering Conditions: I/O pins, 260 °C, ten seconds; fully
compatible with commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model.
Please consult factory for specific model information.
Units are water-washable and fully compatible with commercial
spray or immersion post wave-solder washing equipment.
General
Turn-On Time
10 ms
Remote Shutdown
Positive/Negative Logic
Switching Frequency
400 kHz
Ioain
slto
Input - Output
1500 VD C
Output - Case
500 VD C
Temperature Coeff c e t
iin
0.02 ppm/ C
Case Temperature
Operating Range
- 0 To +100 C
4
Storage Range
- 0 To +100 C
4
Humidity Max., Non-Condensing
95%
Vi r t o , 3 Axes, 5 Min Each
bain
5 g, 10 - 55 Hz
M TBF (Bellcore TR-NWT-000332)
2.5 X 106 h s
r
Safety
UL, cUL, T U V
MCD10042 Rev. 1.0, 06-Feb-08
Page 1 of 2
www.power-one.com
LES DC-DC Series Data Sheet
Single-Output, 15 Watts
Model Selection
MODEL
INPUT VOLTAGE
(VOLTS)
INPUT VOLTAGE
RANGE (VOLTS)
MAXIMUM INPUT
CURRENT (AMPS)*
OUTPUT
VOLTAGE (VOLTS)
RATED OUTPUT
CURRENT (AMPS)
RIPPLE & NOISE
pk-pk (mV)
TYPICAL
EFFICIENCY**
LES008YD
LES010YE
LES015YG
LES015YH
LES015YJ
LES008ZD
LES010ZE
LES015ZG
LES020ZG
LES015ZH
LES015ZJ
NOTES:
24
24
24
24
24
48
48
48
48
48
48
18-36
18-36
18-36
18-36
18-36
36-75
36-75
36-75
40-60
36-75
36-75
0.6
0.8
1.1
1.3
1.3
0.35
0.4
0.6
0.63
0.65
0.65
2.5
3.3
5
12
15
2.5
3.3
5
5
12
15
3.00
3.00
3.00
1.25
1.00
3.00
3.00
3.00
4.00
1.25
1.00
75
100
100
120
150
75
100
100
100
120
150
77%
81%
84%
85%
86%
77%
81%
83%
84%
86%
86%
* Maximum input current at minimum input voltage, maximum rated output power.
** At nominal Vin, rated output.
Model numbers highlighted in yellow or shaded are not recommended for new designs.
Mechanical Drawing
1.00"
(25.4mm)
0.18" MIN.
(4.6mm)
BOTTOM VIEW
0
4
5
6
2.00"
(50.8mm)
0.800"(20.3mm)
1
2
3
DIA 0.040"
(1.0mm)
1.40"(35.6mm)
0
0.300"
(7.6mm)
0.900"
(22.9mm)
0.800"
(20.3mm)
0.500"
(12.7mm)
0.400"
(10.2mm)
0.40"
(10.2mm)
Thermal Impedance
Natural Convection
100 LFM
200 LFM
300 LFM
400 LFM
15.4 °C/W
12.2 °C/W
9.3 °C/W
7.4 °C/W
6.4 °C/W
Pin
1
2
3
Function
+Vin
-Vin
no pin
(Optional shutdown
Pin)
+Vout
no pin
(Optional Trim Pin)
-Vout
Tolerances
Inches:
.XX – 0.020
.XXX – 0.010
Pn
i:
– 0.002
Case:
+ 0.04, - 0.00
(Millimeters)
. –05
X .
.X–02
X
.5
– 0.05
Note:
Thermal impedance data is
dependent on many environmen-
tal factors. The exact thermal
performance should be validated
for specific application.
4
5
6
+10 -00
., .0
(Dimensions as listed unless
ohrie
tews
seiid)
pcfe.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components
in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective
divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date
manufactured. Specifications are subject to change without notice.
MCD10042 Rev. 1.0, 06-Feb-08
Page 2 of 2