7596-100 Overview

Variable Capacitance Accelerometer

Variable Capacitance Accelerometer
Model 7596A
Economical and Rugged
2 to 100 g Full Scale
DC Response
Gas Damped Sensor
Mechanical Over-range Stops
Actual size
ENDEVCO
MODEL
7596A
DESCRIPTION
The ENDEVCO
®
Model 7596A VALULINE™
accelerometer family is a low cost solution to low-level,
low frequency measurements. Applications include labora-
tory measurements, ground transportation studies and mea-
surements where the accelerometer will be subjected to
high shock levels (up to 10 000 gs, see specifications).
The 7596A is ideal for modal studies on large structures.
Gas damping and internal overange stops enable the
anisotropically etched silicon microsensors to withstand
high shocks and acceleration loads. The use of gas damp-
ing, in the sensor, results in very small-induced changes of
frequency response. The patented sensor design ensures
immediate stability making the unit ready to take accurate
DC or dynamic data within one millisecond!
The 7596A can operate from 8.5Vdc to 30Vdc and pro-
vide a high level, low impedance output. The output is
high enough to drive most laboratory instruments, tape
recorders and data acquisition systems without amplifica-
tion or signal conditioning. The output can be fed into
either a differential or single-ended amplifier or standard
bridge electronics with 10Vdc excitation.
ENDEVCO Model 136 Three-Channel System, Model
4430A or OASIS Computer-Controlled
System are
recommended signal conditioners.
SPECIFICATIONS
PERFORMANCE CHARACTERISTICS:
All values are typical at +75°F (+24°C) and 15 Vdc excitation unless otherwise stated. Calibration data, traceable to
the National Institute of Standards, (NIST), is supplied.
Units
g pk
mV/g
Hz
Hz
% FSO Typ
% FSO (Max)
% Typ
mV Max
%/°F
%/°C
7596-2
±2
1000 ±100
0 to 15
1300
±0.20
±0.50
1
±200
3.0
+0.04
+0.08
-10
±10
200 ±20
0 to 500
3000
±0.20
±0.50
1
±200
0.7
+0.04
+0.08
-30
±30
66 ±8
0 to 800
5500
±0.20
±0.50
1
±200
0.7
+0.04
+0.08
-50
±50
40 ±4
0 to 1000
5500
±0.2
±0.5
1
±200
0.6
+0.04
+0.08
-100
±100
20 ±2
0 to 1000
6000
±1
±2
1
±200
0.6
+0.04
+0.08
RANGE
SENSITIVITY (at 100 Hz) [1] [2]
FREQUENCY RESPONSE (± 5%)
MOUNTED RESONANCE FREQUENCY
NON-LINEARITY AND HYSTERESIS [3]
TRANSVERSE SENSITIVITY [4]
ZERO MEASURAND OUTPUT [2]
DAMPING RATIO
DAMPING RATIO CHANGE
From -65°F to +250°F ( -55°C to +121°C)
APPLIES TO CALIFORNIA FACILITY

7596-100 Related Products

7596-100 7596-10 7596A 7596-2 7596-30 7596-50
Description Variable Capacitance Accelerometer Variable Capacitance Accelerometer Variable Capacitance Accelerometer Variable Capacitance Accelerometer Variable Capacitance Accelerometer Variable Capacitance Accelerometer
What version of WINCE do you use now?
Dear seniors, what version of WINCE are you developing now? And what operating system is used for the development environment? I just started to learn it; I don't understand it, please enlighten me......
落寒残梦 Embedded System
QuartusII NoDevice Problem
I just installed QuartusII, and it shows No Hardware in the download. When I click Add Hardware, it says kernel mode driver not installed. I searched for a solution online for a long time, but couldn'...
ulovefw FPGA/CPLD
PCB software training materials
1. How to distinguish which software to use to open a pcb file? Answer: Use Notepad or WordPad to open the pcb file first. If the file has sequential numbers and letters, you can use Protel 99 SE. If ...
mgqzm PCB Design
wince add IIC bus driver
I have never done this kind of development before. I am new to it and don't know where to start. Can anyone who has done it introduce it to me? Or can someone who has done it send me a file to look at...
liujianak Embedded System
A picture I saw in the group, a chance to relax while preparing for the competition!
[i=s]This post was last edited by paulhyde on 2014-9-15 03:06[/i] Go crazy!:lol...
fish001 Electronics Design Contest
The main factors that can affect UWB indoor positioning
UWB indoor positioning, as a centimeter-level positioning technology, can theoretically achieve millimeter-level or even micron-level accuracy. However, when deploying UWB positioning systems in actua...
兰博 RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1930  2726  410  2567  535  39  55  9  52  11 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号