EEWORLDEEWORLDEEWORLD

Part Number

Search

RUE185

Description
PTC RESET FUSE 30V 1.85A RADIAL
CategoryCircuit protection   
File Size103KB,11 Pages
ManufacturerLittelfuse
Websitehttp://www.littelfuse.com
Download Datasheet Parametric View All

RUE185 Online Shopping

Suppliers Part Number Price MOQ In stock  
RUE185 - - View Buy Now

RUE185 Overview

PTC RESET FUSE 30V 1.85A RADIAL

RUE185 Parametric

Parameter NameAttribute value
typepolymer
Voltage - maximum30V
Current - maximum40A
Current - Hold (Ih) (maximum)1.85A
Current - Trip (It)3.7A
Trip time8.7s
Resistance - Initial (Ri) (minimum value)30 mOhms
Resistor - after trip (R1) (maximum value)90 mOhms
Operating temperature-40°C ~ 85°C
grade-
Installation typeThrough hole
Package/casingRadial, disc type
size/dimensions0.402" long x 0.118" wide (10.20mm x 3.00mm)
Height - Installation (maximum)0.618"(15.70mm)
Thickness (maximum)-
lead spacing0.201"(5.10mm)
ApprovalCSA,TUV,UR
RUE
Selection Guide
and Product Data
This section has two parts:
• A Selection Guide that walks you through the process of
selecting the correct RUE device for a circuit.
• Product Data that outlines electrical characteristics,
physical characteristics, agency recognitions, environmental
specifications, component layouts, tape and reel specifications,
and ordering information for RUE devices.
RUE Selection Guide
Follow these seven steps to select a PolySwitch RUE device for
a circuit:
1. Define the operating parameters for the circuit.
These include:
• Maximum ambient operating temperature
• Normal operating current
• Maximum operating voltage (RUE is 30 V maximum)
• Maximum interrupt current
2. Select the RUE device that accommodates the circuit’s maximum
ambient operating temperature and normal operating current.
3. Compare the RUE device’s maximum operating voltage and maxi-
mum interrupt current with the circuit’s to be sure the circuit does not
exceed the device ratings.
4. Check the RUE device’s time-to-trip to be sure it will protect the
circuit.
5. Verify that the circuit’s ambient operating temperatures are within the
RUE device’s operating temperature range.
6. Verify that the RUE device’s dimensions fit the application’s space
considerations.
7. Independently evaluate and test the suitability and performance
of the RUE device in the application.
4
®
®
TUV Rheinland
Raychem Circuit Protection Devices
RUE Devices
141

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1955  1887  834  2471  885  40  38  17  50  18 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号