EEWORLDEEWORLDEEWORLD

Part Number

Search

7032-06-BCS-P03

Description
Network Interface Device
File Size247KB,2 Pages
ManufacturerBourns
Websitehttp://www.bourns.com
Download Datasheet View All

7032-06-BCS-P03 Overview

Network Interface Device

7032-06-BCS-P03 Preview

Features
Six 7032 Models designed to accept all
Bourns station protectors
Accepts all other manufacturers’
protection of similar design
Optional sealed switching jacks with
Insulation Displacement Connectors
(IDCs)
UL
Listed per UL 497 (File: E53117)
®
7032 Series – Network Interface Device
The Model 7032 NID is designed to allow service providers the capacity to terminate and add protected service pairs as
needed. The 7032 NID is available in pair counts of 1 through 100. Enclosures are manufactured of high-impact resistant, ultra-
violet-desensitized, flame retardant UL Listed plastic (50 and 100 pair models are 18 gauge rust resistant zinc-coated steel,
with twenty-five pair available in both plastic and steel). This 7032 is completely subscriber lockable with Telco override and
subscriber friendly termination posts for safe and secure operation.
How To Order
7032 - XX - X X X - X XX
Model Number Designator
Number of Lines
06, 12, 25, 50, 100
Station Protector Options
D
1
=
Z
1
=
E=
Y=
B=
C=
L=
M=
T=
O=
455HS-MSP (2377-45-HS) Broadband Voice/Data Services
455HS-BC (2377-45-BC) Balance-Sensitive DSL Systems
155HS-MSP (2378-35-HS) Broadband Voice/Data Services
155HS-BC (2378-35-BC) Balance-Sensitive DSL Systems
125EW (2374-01) Dual Gas Tube (UL, cUL, Telcordia)
125EW-R (2375-01) Dual Gas Tube (UL, cUL, RUS)
356M (2377-01) Balanced Gas Tube (UL, cUL, RUS)
J130S (2380-27-01) Solid State Protector (UL, cUL)
Tii355M
No Station Protectors (Not available with DSL configurations)
Note 1 = Digi. Guard
Enclosure Size and Construction
(see table for dimensions)
E = 100 Pair Capacity (Steel)
A = 6 Pair Capacity (Plastic)
B = 12 Pair Capacity (Plastic)
P = 1/2 inch Plywood-no enclosure
C = 25 Pair Capacity (Steel)
V = 25 Pair Capacity (Plastic)
D = 50 Pair Capacity (Steel)
Special Options
S = Sealed Switching Jack w/IDC (85122-T-IDC)
F = Sealed Switching Jack 4-Post (85122-T4)
J = Modular Jacks (85122)
B = Expansion Bridge w/Binding Posts (85122-B)
I = Expansion Bridge w/IDC (85122-IDC)
X = Dual Ground Plate
O = No options
DSL Options
A = One 3610A, ADSL POTS Splitter
P = One 3610A2, ADSL 2+ POTS Splitter
V = One 3630A, VDSL POTS Splitter
Number of DSL Lines
03, 06, 12, 25, 50
To add lines, use station protector + upgrade kit 85003 (old style) or:
85122
Standard Jack (Not available with DSL configurations)
85122-T4
Sealed Switching Jack, 4-post
85122-T-IDC Sealed Switching Jack w/IDC
*DSL Configuration Note: 3610A
or
3630A
must be ordered with option
D, Z, E or Y
Station Protectors.
REV. G 05/06
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
7032 Series – Network Interface Device
Product Dimensions
Enclosure
Size
A
B
C
D
E
V
Pair
(Max.)
06
12
25
50
100
25
DSL
(Max.)
03
06
12
25
50
12
Dimensions
High
279.4
(11.0)
444.5
(17.5)
431.8
(17.0)
914.4
(36.0)
914.4
(36.0)
469.9
(18.5)
Wide
279.4
(11.0)
279.4
(11.0)
406.4
(16.0)
482.6
(19.0)
508
(20.0)
444.5
(17.5)
Deep
101.6
(4.0)
127
(5.0)
76.2
(3.0)
114.3
(4.5)
177.8
(7.0)
139.7
(5.5)
DIMENSIONS:
MM
(INCHES)
RJ11 Subscriber Bridges
Expansion Bridges
85122
Standard Loop
85122-T4*
Internal Switch - 4 Lugs
85122-IDC
Insulation Displacement
Connectors
TR
1
TR
2
TR
3
TR
4
85122-B
Binding Post
85122-T-IDC*
Sealed Switch Jack w/IDC
*Includes environmental sealant and closed-cell foam gasket.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications.
What is the minimum size of Vxworks' bootrom_uncomp.bin?
I want to port Vxworks5.5 and Tornado2.2 to the XScale-PXA270 project. At the beginning, when the bootrom didn't work, I could only use the parallel port to burn (there was no high-speed burner), whic...
06050341 Real-time operating system RTOS
About the register reading and writing problem of CAN IP downloaded from opencore
This incident originated from my graduation project. It was such a lousy graduation project. . . . . . .The initial idea was to integrate a CAN controller into the FPGA, and then collect external sens...
心情绿茶 FPGA/CPLD
DTS/Dolby Digital AC-3 Audio Decoder Board (DA32UD)
Adopt CS493263 audio DSP, CS8415 96KHz digital receiver, 96KHz/24bit ADC and DAC. Support Dolby Digital AC-3, Dolby Pro Logic, DTS, PCM and other 5.1 channel decoding. STL215 microcontroller can direc...
hsav Analog electronics
New understanding of Stellaris series UART FIFO, classic!
[Classic Question]  Is there any way to remove the UART FIFO, or how can we achieve an interrupt for each character sent or received? The Stellaris series ARM UART seems unable to do this, and there a...
wanghongyang Microcontroller MCU
PIC microcontroller two-way analog programming help
Can any great god help me learn from the programming example of two-way analog quantity of PIC microcontroller? Thank you...
czwukun Microchip MCU
About the development of network card driver!!
I have written a network card driver myself, but I just can't connect. Does anyone have experience in driver development? Can you share with me? Thank you...
rongfengtantg Embedded System

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1523  1171  1956  1761  794  31  24  40  36  16 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号