EEWORLDEEWORLDEEWORLD

Part Number

Search

8340-F920-P1K2-KLH0-15A

Description
CIR BRKR MAG 15A 240VAC 80VDC
CategoryCircuit protection   
File Size455KB,6 Pages
ManufacturerE-Switch
Websitehttp://www.e-switch.com
Environmental Compliance
Download Datasheet Parametric View All

8340-F920-P1K2-KLH0-15A Online Shopping

Suppliers Part Number Price MOQ In stock  
8340-F920-P1K2-KLH0-15A - - View Buy Now

8340-F920-P1K2-KLH0-15A Overview

CIR BRKR MAG 15A 240VAC 80VDC

8340-F920-P1K2-KLH0-15A Parametric

Parameter NameAttribute value
Circuit breaker typeMagnetic
Rated current15A
Rated voltage - AC240V
Rated voltage - DC80V
Number of poles2
Actuator typepress slice
illumination-
Lighting voltage (nominal)-
Installation typePanel mounting
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...
Description
Single and multipole magnetic circuit breakers with trip-free
mechanism and toggle actuation. A choice of fast magnetic only or
hydraulically delayed switching characteristics (S-type MO or HM
CBE to EN 60934) ensures suitability for a wide range of applications.
Industry standard dimensions and panel mounting. Options include
auxiliary changeover contacts. Low temperature sensitivity at rated
load.
Approved to CBE standard EN 60934 (IEC 60934).
Typical application
Control equipment, communications systems, transportation, power
supplies.
1-pole
8340-F...
1
2-pole
Standard current ratings and typical internal resistance values
Current
rating (A)
0,02
0,05
0,1
0,25
0,5
0,75
1
2
2,5
3
5
6
8
10
12
15
16
20
25
30
40
50
Internal resistance values (Ω) per pole
F1
1 493
276
58
8,2
2,3
0,98
0,58
0,145
0,096
0,065
0,025
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,01
< 0,01
953
152
37
6,0
1,47
0,63
0,35
0,096
0,061
0,048
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
-
-
F2
K1, M1, T1
2 669
452
100
15,5
3,9
1,65
0,95
0,26
0,15
0,10
0,042
0,029
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,01
< 0,01
K2, M2, T2
2 457
376
94
14,7
3,2
1,56
0,90
0,20
0,15
0,10
0,040
0,028
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
-
-
Technical data
For further details please see chapter: Technical Information
Voltage rating
3 AC 415 V; AC 240 V, 50/60 Hz; DC 80 V
(higher DC ratings to special order)
Current ratings
0.02...50 A DC
0.02...30 A AC
Auxiliary circuit
6 A, AC 240 V;
3 A, DC 28 V
1 A, DC 65 V;
0.5 A, DC 80 V
Typical life
3 AC 415 V, AC 240 V:
0.02...30 A
6,000 operations at 1 x I
N
, inductive
10,000 operations at 1 x I
N
, resistive
DC 80 V: 0.02...25 A
6,000 operations at 1 x I
N
, inductive
0.02...30 A
10,000 operations at 1 x I
N
, resistive
40 + 50 A
6,000 operations at 1 x I
N
, resistive
Ambient temperature
-40...+85 °C (-40...+185 °F)
Insulation co-ordination
rated impulse
pollution
(IEC 60664 and 60664A) withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A)
operating area
test voltage AC 3,000 V
Line to Load
test voltage AC 1,500 V
pole to pole
(2- and 3-pole)
test voltage AC 1,500 V
main to auxiliary circuit
test voltage AC 3,000 V
switching to trip circuit
test voltage AC 1,500 V
(version -X)
Insulation resistance
> 100 MΩ (DC 500 V)
Interrupting capacity
6 x IN at AC;
IEC 60934 - test sequence E 4 x IN at DC
Interrupting capacity
(UL 1077)
AC:
1-pole
2-pole
3-pole
1-pole
2-pole
I
N
0.02...20 A
25...30 A
AC 250 V/3,500A AC 250 V/3,500A
AC 250 V/3,500A AC 250 V/5,000A
3AC 250V/3,500A 3AC250V/5,000A
0.02...50 A
0.02...30 A
DC 80 V/3,500 A
DC 80 V/3500 A
DC:
Degree of protection
(IEC 60529/DIN 40050)
Vibration
with toggle down:
directions 1, 2, 3, 4, 5:
Shock
Corrosion
Humidity
Mass
1747
www.e-t-a.de
operating area IP40
terminal area IP00
10 g (57-2000Hz) ± 0.76 mm (10-57 Hz)
at 0.9 x IN
10 g (57-2000 Hz) at 1 x IN.
100 g (11 ms) at 1 x IN, directions 1,2,3,4,5
100 g (11 ms) at 0.8 x IN, direction 6.
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH
to IEC 60068-2-78, test Cab
approx. 65 g per pole
1
Registration for 2013 TI Battery Management Seminar Series is now open!!
In 2013, Texas Instruments (TI) is ready to launch a new seminar series - Battery Management Seminar. The latest charging innovation technology, the most authoritative power measurement and battery au...
wstt Energy Infrastructure?
The ST-link indicator light suddenly turns off and cannot be used
The indicator light of ST-link suddenly went off, and then this problem occurred. The burning program prompted that there was no STLINK. What is this problem and how to solve it?...
也许想你 stm32/stm8
Xiaobai asks for help, the TDR at home is broken
I need help. My TDR is broken and not connected to anything. It should show disconnected, but it shows a straight line, just like you connect a 50Ω load to the port. It's the same when you connect a s...
huashengzi Test/Measurement
dsp car tracking
Rookie help!...
qqxiaoai DSP and ARM Processors
2008 Intel Cup Undergraduate Electronic Design Competition - Embedded System Special Invitational Competition First Prize
[i=s] This post was last edited by paulhyde on 2014-9-15 09:01 [/i] Participating school Hangzhou Dianzi University Instructor Shen Xingfa Participating team members Zhang Bin Wu Jibing Chen Ning Titl...
open82977352 Robotics Development
The output voltage of the regulated power supply keeps rising
1. Is it normal that the voltage output by the regulated power supply keeps rising slowly? 2. How can I improve the load capacity? With a 3V output voltage, the voltage will drop below 3V if the load ...
tww1994 Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 170  1654  2325  1403  1838  4  34  47  29  38 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号