D4N-6C20

Description
SWITCH SNAP ACTION 3PST 10A 120V
CategoryMechanical and electronic products    switch   
File Size6MB,20 Pages
ManufacturerOMRON
Websitehttps://www.omron.com
Environmental Compliance
Download Datasheet Parametric View All

D4N-6C20 Online Shopping

Suppliers Part Number Price MOQ In stock  
D4N-6C20 - - View Buy Now

D4N-6C20 Overview

SWITCH SNAP ACTION 3PST 10A 120V

D4N-6C20 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerOMRON
Reach Compliance Codeunknown
ECCN codeEAR99
Factory Lead Time14 weeks
Actuator typeROLLER LEVER
Other featuresP.T.= 27 DEG, O.T.= 67 DEG
body width30 mm
body height56 mm
Body length or diameter56 mm
Contact (AC) maximum rated R load10A@240VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)2.5 A
Contact (DC) maximum rated R load2.5A@250VDC
Maximum contact voltage (AC)240 V
Maximum contact voltage (DC)250 V
Electrical life300000 Cycle(s)
Manufacturer's serial numberD4N
Installation featuresPANEL MOUNT
Maximum operating force5 N
Maximum operating temperature70 °C
Minimum operating temperature-30 °C
sealIP67
surface mountNO
Switch actionMOMENTARY
switch function3PST
Switch typeSNAP ACTING/LIMIT SWITCH
Termination typeSCREW
Safety Limit Switch
D4N
CSM_D4N_DS_E_10_1
Popular Safety Limit Switches
Providing a Full Lineup Conforming to
International Standards
• Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and
3NC contact forms.
(Slow-action models with MBB contacts are available.)
• M12-connector models are also available, saving on labor and
simplifying replacement.
• Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
• Conforms to the requirements for safety contacts in EN 115-1,
EN 81-20, and EN 81-50 (slow-action models only).
• Certified standards: UL, EN (TÜV), and CCC
Be sure to read the
“Safety Precautions”
on page 17.
Note:
Contact your sales representative for details on models
with safety standard certification.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Model Number Structure
Model Number Legend
1-Conduit Models
2-Conduit Models
D4N-@@@@
1 2
3
1. Conduit size
1: Pg13.5
2: G1/2
4: M20
9: M12 connector
2. Built-in Switch
1: 1NC/1NO (snap-action)
2: 2NC (snap-action)
A: 1NC/1NO (slow-action)
B: 2NC (slow-action)
C: 2NC/1NO (slow-action)
D: 3NC (slow-action)
E: 1NC/1NO (MBB contact) (slow-action)
F: 2NC/1NO (MBB contact) (slow-action)
3. Head and Actuator
20: Roller lever (resin lever, resin roller)
22: Roller lever (metal lever, resin roller)
25: Roller lever (metal lever, metal roller)
26: Roller lever (metal lever, bearing roller)
2G: Adjustable roller lever, form lock (metal lever, resin roller)
2H: Adjustable roller lever, form lock (metal lever, rubber roller)
31: Plunger
32: Roller Plunger
62: One-way roller arm lever (horizontal)
72: One-way roller arm lever (vertical)
80: Cat whisker
87: Plastic rod
RE: Fork lever lock (right operation)
LE: Fork lever lock (left operation)
D4N-@@@@
1 2
3
1. Conduit size
6: G1/2
8: M20
2. Built-in Switch
1: 1NC/1NO (snap-action)
2: 2NC (snap-action)
A: 1NC/1NO (slow-action)
B: 2NC (slow-action)
C: 2NC/1NO (slow-action)
D: 3NC (slow-action)
E: 1NC/1NO (MBB contact) (slow-action)
F: 2NC/1NO (MBB contact) (slow-action)
3. Head and Actuator
20: Roller lever (resin lever, resin roller)
22: Roller lever (metal lever, resin roller)
25: Roller lever (metal lever, metal roller)
26: Roller lever (metal lever, bearing roller)
2G: Adjustable roller lever, form lock (metal lever, resin roller)
2H: Adjustable roller lever, form lock (metal lever, rubber roller)
31: Plunger
32: Roller Plunger
62: One-way roller arm lever (horizontal)
72: One-way roller arm lever (vertical)
1
ISM303DAC three-axis acceleration + three-axis magnetometer sensor package and code
Data sheet:Code:Package:Official evaluation board gerber file:...
littleshrimp MEMS sensors
Ultrasonic distance measurement system based on ARM7&μCOSII
I have recently received a project, which is mainly to use the integrated development tool of ARM Developer Suite to measure the distance of ultrasonic sensors (using Philips' 51 single-chip microcomp...
jxpxlee Robotics Development
Let's talk about the constant current drive principle of LED lighting
LED is a semiconductor device with sensitive characteristics and negative temperature characteristics. Therefore, it needs to be stabilized and protected during the application process, which gives ri...
qwqwqw2088 LED Zone
VISHAY Electricians are awesome
:)...
淼淼一江 Discrete Device
Strange interruption
I used IAR v5.4 to write a C code based on 8962. It used a structure array. When the length of the array is less than a certain value, the program is OK, but when it exceeds this length, the program c...
Yawness Microcontroller MCU
Flexible use of Altium Designer's special string
"An important rule of data management is to make specific identification marks for each file generated during the design process, including version numbers. The special characters provided by Altium D...
okhxyyo PCB Design

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 761  2781  2219  2385  163  16  56  45  49  4 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号