EEWORLDEEWORLDEEWORLD

Part Number

Search

MS20CW

Description
CABLE FLOAT SPDT 20A PVC
CategoryThe sensor   
File Size252KB,2 Pages
ManufacturerCynergy 3
Environmental Compliance
Download Datasheet Parametric View All

MS20CW Online Shopping

Suppliers Part Number Price MOQ In stock  
MS20CW - - View Buy Now

MS20CW Overview

CABLE FLOAT SPDT 20A PVC

MS20CW Parametric

Parameter NameAttribute value
typeliquid
Output typeSwitch (single float)
Output configurationSPDT
current20A
switch actuation level-
Installation typeCable installation
Materials - Shells and PrismsHigh density polyethylene (PEHD)
Operating temperature0°C ~ 55°C
Rated voltage110VDC,250VAC
MS Series
The MS series of cable end float switches are designed for controlling levels in large tanks,
cisterns or reservoirs and can be directly installed on submersible pumps. The casing is
manufactured in blow moulded Polyethylene (HDPE), with 5m PVC cable with protective
earth conductor as standard*. The switching element is a microswitch, with UL, VDE and
CENELEC approvals, activated by a moving stainless steel ball and having an electrical life
of 200,000 operations. Non-hygroscopic closed-cell expanded polyurethane is injected
around the switch housing within the outer casing, hermetically sealing the unit. It is
capable of working down to 100 metres depth in water.
The “U” version with polyurethane cable is for use in fuel oils.
* = protective earth wire not included on “C” (C/O) versions.
Contact
Part No.
Form
MS10A
MS10AU
MS10B
MS10BU
MS10C
MS10CU
MS20A
MS20AU
MS20B
MS20BU
MS20C
MS20CU
N/O
N/O
N/C
N/C
C/O
C/O
N/O
N/O
N/C
N/C
C/O
C/O
Switching Current Max.
(Amps)
Resistive
10
10
10
10
10
10
20
20
20
20
20
20
AC
4
4
4
4
4
4
8
8
8
8
8
8
1
1
1
1
1
1
2
2
2
2
2
2
Power Rating
Switching
Cable
Body Temp. Range
Cable
Max.
Max.
Voltage Max.
Length
Matl.
Matl.
Pressure
o
o
*
C
F
Inductive AC (VA) DC (W) AC
DC
750
750
750
750
750
750
1500
1500
1500
1500
1500
1500
180
180
180
180
180
180
360
360
360
360
360
360
250
250
250
250
250
250
250
250
250
250
250
250
110
110
110
110
110
110
110
110
110
110
110
110
PVC
PUR
PVC
PUR
PVC
PUR
PVC
PUR
PVC
PUR
PVC
PUR
5m
5m
5m
5m
5m
5m
5m
5m
5m
5m
5m
5m
HDPE 0-55 32-131 10 bar
HDPE 0-55 32-131 10 bar
HDPE 0-55 32-131 10 bar
HDPE 0-55 32-131 10 bar
HDPE 0-55 32-131 10 bar
HDPE 0-55 32-131 10 bar
HDPE 0-55 32-131 10 bar
HDPE 0-55 32-131 10 bar
HDPE 0-55 32-131 10 bar
HDPE 0-55 32-131 10 bar
HDPE 0-55 32-131 10 bar
HDPE 0-55 32-131 10 bar
* = protective earth wire included except on “C” (C/O) versions.
Mechanical
• Direct power
switching
• Cable mounting
• 100 metre depth
capability
Cynergy3 Components Ltd
7 Cobham Road
Ferndown Industrial Estate
Wimborne
Dorset BH21 7PE
Tel: +44 (0) 1202 897969
sales@cynergy3.com
ISO 9001
C E R T I F IED
MS 2016
© 2016 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited.
www
.cynergy3.com
Release several boards, MSP430, MT7620
There are several boards that are idle: 1. LSD-MSP430F5438 development board, with an LCD, accelerometer, MIC, and various basic peripherals, 2 pieces, 100 yuan each 2. MT7620 development board, 580MH...
losingamong Buy&Sell
Why is the menu of my VS2005 messed up? Under the Build menu option, Build becomes the function of Rebuild, and Bushu becomes the function of Rebuild + Bushu (Download). Under the Debug menu, Start Debugging becomes Bushu (Download) +
Why is the menu of my VS2005 messed up? Under the Build menu option, Build became the Regenerate function, and Download became the Regenerate + Download (Download) function. Under the Debug menu, Star...
jsytdx Embedded System
Has anyone used CO detector devices?
I want to find a commonly used and easy to buy one for my personal experiment! ! Thank you very much, provide a model, preferably with a schematic diagram and parameters~~ I will be very grateful, I a...
zqh1630 Industrial Control Electronics
ModelSim simulation error
Has anyone encountered this problem? Waiting for a solution online. Thank you very much!...
my_style FPGA/CPLD
How to locate the address of the data packet in MDK and download it to STM32
If you need to use a relatively large database in your STM32 project and the program needs to access it, you can modify the connection script to locate your data in the interval you specify, or direct...
小野狼 stm32/stm8
Technical Science: The Essential Differences between DRAM and NAND
DRAM is one of the storage devices we deal with every day. You may be unfamiliar with the abbreviation of DRAM, which means dynamic random access memory in Chinese. To enhance your understanding of DR...
eric_wang Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1762  1311  2592  255  1951  36  27  53  6  40 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号