EEWORLDEEWORLDEEWORLD

Part Number

Search

3E-8PT-5.5

Description
MEDIUM BLOW ELECTRIC FUSE, 2A, 8250VAC, 50000A (IR), INLINE/HOLDER
CategoryCircuit protection    Circuit protection   
File Size330KB,12 Pages
ManufacturerLittelfuse
Websitehttp://www.littelfuse.com
Download Datasheet Parametric View All

3E-8PT-5.5 Overview

MEDIUM BLOW ELECTRIC FUSE, 2A, 8250VAC, 50000A (IR), INLINE/HOLDER

3E-8PT-5.5 Parametric

Parameter NameAttribute value
Reach Compliance Codeunknow
ECCN codeEAR99
Fusing characteristicsMEDIUM
body height241.3 mm
Body length or diameter39.69 mm
Circuit protection typeELECTRIC FUSE
Installation featuresINLINE/HOLDER
physical size39.69mm x 241.3mm
Rated breaking capacity50000 A
Rated current3 A
Rated voltage (AC)5500 V
surface mountNO
Terminal shapeEND CAP
Base Number Matches1
Medium Voltage Fuses
2400 - 25,500 VAC
s
Current Limiting
Current limiting “E” and “R”
rated fuses are equipped with
a mechanical indicator or
striker pin that protrudes
through the fuse cap upon
operation of the fuse. This
provides visual identification
of a blown fuse and can be
used as a trigger for external
devices.
GENERAL INFORMATION
The terms “Medium Voltage” and “high voltage” have been
used interchangeably by many people to describe fuses
operating above 600 volts. Technically speaking, “medium
voltage” fuses are those intended for the voltage range from
2,400 to 38,000 VAC. “High voltage fuses are for circuits
carrying voltages greater than 38,000 VAC.
“E” Rated fuses are considered to be general purpose fuses
and can be used to protect against low and high values of
fault current. “R” rated fuses are designed for back-up pro-
tection. They must be used in series with other devices, such
as motor overload relays, in order to achieve both overload
and short circuit protection.
Medium voltage fuses are not intended to provide overload
protection in the same sense as fuses rated 600 volts or
less. Medium voltage fuse current ratings do not have the
same meanings as the ampere ratings of low voltage fuses.
All medium voltage fuses are limited in their ability to inter-
rupt low value overcurrents, especially those between 100%
and 200% of the fuse’s continuous current rating. They are
designed to carry their rated current without exceeding the
temperature rise permitted by NEMA and ANSI standards.
Additional application data can be found in the Fuse
Application section of the POWR-GARD Products
catalog (PF101).
Littelfuse now offers a complete selection of “E” and “R”
rated medium voltage fuses for the protection of trans-
formers, potential transformers, feeders, and motor circuits.
Single, double, and triple barrel designs are available to
cover a wide range of current, voltage, and interrupting
ratings. Conventional ferrule type, clip lock, and bolt-in
mounting configurations are now available for virtually any
application. Hermetically sealed fuses for use in hazardous
environments are also offered.
Contact the factory or your local Littelfuse representative for
additional fuse ratings or custom mounting configurations.
24 Hour Emergency Service is available.
Call 1-800-227-0029.
APPLICATIONS
s
s
s
s
s
Power Transformer
Protection
Potential Transformer
Protection
Motor Controller Back-up
Protection
Fused Switches
Feeder Circuits
Bolt-in Mount Fuses
61
Don’t be silly (4): Never say no to others
Are you a "nice guy" in the company? If you just flatter others, you will lose their respect. Every company has nice guys who smile at everyone and never say "NO" to anyone's request. If you are a new...
Lazy_Boy Talking about work
Max485 receiving enable problem
Good afternoon everyone, I suddenly thought of a question, so I'm here to ask you guys for advice. [align=center][/align] [align=center] [align=left] What I want to ask is, the DE/RE pin is the enable...
liaoyuanhong Industrial Control Electronics
Ask about two small problems in S3C6410 Camera
1. Caution! All external camera interface IOs must not be combined with any other GPIO or bi-directional ports. The above sentence seems to mean that all camera external IO interfaces cannot be "combi...
tiantangii Embedded System
What is the best radius for a serpentine line?
The PCB needs to have equal length snake lines, how big should the fillet be?...
琉璃珠 Analog electronics
EEWORLD University Hall----DDR memory interface inspection and debugging
DDR memory interface verification and debugging : https://training.eeworld.com.cn/course/3518...
phantom7 Test/Measurement
Does anyone have any good ideas for human body temperature monitoring circuits?
Does anyone have any good ideas for human body temperature monitoring circuits? For example, what simple way can be used to measure human body temperature, such as sticking it on a certain part of a c...
蓝雨夜 Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2133  2318  988  820  604  43  47  20  17  13 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号