PAH100S48-3.3/V

Description
DC DC CONVERTER 3.3V 100W
CategoryPower/power management    The power supply circuit   
File Size240KB,2 Pages
ManufacturerTDK-LAMBDA
Environmental Compliance
Download Datasheet Parametric View All

PAH100S48-3.3/V Overview

DC DC CONVERTER 3.3V 100W

PAH100S48-3.3/V Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerTDK-LAMBDA
package instruction, MODULE,9LEAD,1.9
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresLG-MAX; WD-MAX
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage76 V
Minimum input voltage36 V
Nominal input voltage48 V
length61 mm
Number of functions1
Output times1
Number of terminals9
Maximum output current23.4 A
Maximum output voltage3.63 V
Minimum output voltage2.97 V
Nominal output voltage3.3 V
Package body materialPLASTIC/EPOXY
Encapsulate equivalent codeMODULE,9LEAD,1.9
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
Maximum seat height12.95 mm
technologyHYBRID
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output100 W
Fine-tuning/adjustable outputYES
width57.9 mm
Base Number Matches1
PAH Series
50W to 200W 48V Input Half brick DC-DC Converters
Features
u
Industry Standard Footprint & Pinouts
u
12V output for driving non-isolated converters
u
Safety Approved
u
Full power at 100ºC baseplate
u
Wide Adjustable Output Range
u
Zero Pre-load
u
ASIC Design
u
No potting materials
Key Market Segments & Applications
Specifications
Model
Efficiency (Typ)
Input Voltage range
Output Voltage Accuracy
Max Ripple & Noise
Max Line Regulation
Max Load Regulation
Overcurrent Protection
Overvoltage Protection
Remote Sense
Remote On/Off
Operating Temperature
Overtemperature
Cooling
Isolation Voltage
Shock
Vibration
Amplitude
Safety Agency Approvals
Weight (Typ)
Size (WxHxD)
Warranty
2.5V
3.3V
5V
12V
15V
24V
28V
48V
%
75-76
79-80
83-84
85-86
86-88
88
VDC
36-76
%
±1.6
mV
150
200
280
250
mV
10
24
30
48
56
96
mV
10
24
30
48
56
96
A
105 - 150% automatic recovery
%
120-160 120-140
125-145
135-155
-
Yes
-
Standard; Low = ON, Open = OFF /P option; Low = OFF, Open = ON)
-
-40ºC to +100ºC baseplate
-
Shutdown between 105 - 130ºC, Auto restart
-
Conduction (See Installation Manual for heatsink selection)
V
Input - Baseplate 1500VAC, Input - Output 1500VAC, Output-Baseplate 500VDC
-
196.1m/s
2
-
Non Operating, 10-55Hz (sweep for 1 min.)
-
0.825mm constant (Max 49 m/s
2
) X,Y,Z 1 hour each
-
UL60950-1, CSA60950-1, EN60950-1, CE LVD
g
80
in(mm)
2.28x0.5x2.4 (57.9x12.7x61) See outline drawing
-
2 Years
(1)
(1) See options table.
General: See Installation Manual for full details, test methods of parameters and application notes
1-800-526-2324 • www.us.tdk-lambda.com/lp/
13

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 35  2302  1959  1913  2441  1  47  40  39  50 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号