EEWORLDEEWORLDEEWORLD

Part Number

Search

LKP5742-7PD1T

Description
AC-DC Power Factor Correction Module, 2 Output, 250W, Hybrid, HEAT SINK, METAL, CASE K02, MODULE
CategoryThe power supply circuit   
File Size535KB,23 Pages
ManufacturerBel Fuse
Download Datasheet Parametric View All

LKP5742-7PD1T Overview

AC-DC Power Factor Correction Module, 2 Output, 250W, Hybrid, HEAT SINK, METAL, CASE K02, MODULE

LKP5742-7PD1T Parametric

Parameter NameAttribute value
Brand NamePower-One
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerBel Fuse
Parts packaging codeMODULE
package instruction,
Manufacturer packaging codeCASE K02
Reach Compliance Codecompliant
ECCN codeEAR99
Is SamacsysN
Analog Integrated Circuits - Other TypesAC-DC POWER FACTOR CORRECTION MODULE
Maximum input voltage255 V
Minimum input voltage187 V
Nominal input voltage230 V
JESD-30 codeR-MXMA-X
JESD-609 codee0
Number of functions1
Output times2
Maximum operating temperature71 °C
Minimum operating temperature-25 °C
Maximum output voltage28.25 V
Minimum output voltage25.25 V
Package body materialMETAL
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelCOMMERCIAL EXTENDED
Terminal surfaceTIN LEAD
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output250 W
Fine-tuning/adjustable outputNO
Base Number Matches1
Cassette Style
AC-DC Converters
KP Series
250 Watt AC-DC Converters with PFC
Input voltage from 187...255 V AC
1 or 2 isolated outputs up to 56.5 V DC
4 kV AC I/O electric strength test voltage
• Power factor
>0.95,
harmonics
<IEC/EN61000-3-2
• Output power up to 280 Watt
• Input over- and undervoltage lock-out
• Efficient input filter and built-in surge and transient
suppression circuitry
• Fully isolated outputs
• Outputs open- and short-circuit proof
Safety according to IEC/EN 60950
LGA
KP Series
111
4.4"
3U
Summary
The KP series is an extension of the K series of AC-DC con-
verters with an increased output power level of up to 280 W
depending on the operating ambient temperature require-
ments. The KP converters are optimized for use in
230 V AC mains applications and feature high efficiency,
high reliability, low output voltage noise and excellent dy-
namic response to load/line changes.
The converter inputs are protected against surges and tran-
sients occuring at the source lines. An input over- and
undervoltage lock-out curcuitry disables the outputs if the
input voltage is outside the specified range. The LKP types
include an inrush current limitation preventing circuit break-
ers and fuses from being damaged at switch-on.
The outputs are open- and short-circuit proof and are pro-
tected against overvoltages by means of a built-in suppres-
sor diode. The outputs can be inhibited by a logic signal
applied to the connector pin 18 (i). If the inhibit function is
not used pin 18 must be connected with pin 14 to enable
the outputs (fail safe).
LED indicators display the status of the converter and allow
visual monitoring of the system at any time.
80
3.2"
16 TE
168
6.6"
Full input to output, input to case, output to case and output
to output isolation is provided. The modules are designed
and built according to the international safety standards
IEC/EN 60950.
The case design allows operation up to an operating ambi-
ent temperature of 71°C with reduced output power. De-
pending on the ambient temperature requirements, how-
ever, the output power can be up to 280 W.
An internal temperature sensor generates an inhibit signal
which disables the outputs if the case temperature
T
C
ex-
ceeds the specified limit. The outputs are automatically re-
enabled when the temperature drops below the limit.
Various options are available to adapt the converters to in-
dividual applications. Especially for battery charger applica-
tions an external temperature sensor has been designed to
allow for temperature compensated battery charging.
The modules may either be plugged into 19" rack systems
according to DIN 41494 or be chassis mounted.
Table of Contents
Page
Page
Electromagnetic Compatibility (EMC) ............................ 14
Immunity to Environmental Conditions ........................... 15
Mechanical Data ............................................................ 16
Safety and Installation Instructions ................................ 17
Description of Options .................................................... 20
Accessories .................................................................... 23
Summary .......................................................................... 1
Type Survey and Key Data .............................................. 2
Type Key .......................................................................... 2
Functional Description ...................................................... 3
Electrical Input Data ......................................................... 4
Electrical Output Data ...................................................... 6
Auxiliary Functions ......................................................... 10
Edition 01/01.2001
1/23
Why does ENOTSUP appear when connecting to a socket under vxworks?
The client sends data packets through the socket periodically. Each packet is about 1K. If a small number is sent in a cycle, it is normal. If too much is sent, the connection will be disconnected. Wh...
xsllinlin Real-time operating system RTOS
Four steps to teach you how to use the Open1081 development board
[i=s]This post was last edited by Brother High on 2014-10-21 16:07[/i] :Cry:I got the Open1081 board a few days ago, and I have quite enough time these two days, so I decided to play with it.However, ...
High哥 RF/Wirelessly
About on-chip memory and DMA
If hot boot is not considered, can the 64KB memory at 0xffff0000 be used to store data via DMA? If so, is there anything I need to pay attention to? Is it OK to use mmap in Linux? Thank you....
vlah FPGA/CPLD
What kind of long distance wireless transmission equipment is there?
1. 3G/4G/5G long-distance wireless transmission equipmentThe "far" of 3G/4G/5G long-distance wireless transmission equipment lies in the fact that it uses the power of the Internet. With the help of D...
蓝先生 RF/Wirelessly
DSP introductory information
DSP introductory information...
kandy2059 DSP and ARM Processors
Multifunctional serial port monitoring tool - reference drawings and materials, etc.
I have made a lot of tools about serial ports before, and I share them here to provide reference for netizens who are making "Multi-function Serial Port Detection Tools". [align=center][/align]Product...
zhaojun_xf stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 557  2153  1616  2901  1024  12  44  33  59  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号