313LDPNAAFLGE

Description
SUBMERSIBLE LEVEL TRANSMITTER
File Size89KB,2 Pages
ManufacturerETC
Download Datasheet View All

313LDPNAAFLGE Overview

SUBMERSIBLE LEVEL TRANSMITTER

SUBMERSIBLE LEVEL TRANSMITTER
Model 313L
GENERAL PURPOSE
FEATURES:
All-welded, stainless steel construction
Rugged, all encapsulated electronics.
Leakproof
1/2” NPT conduit thread standard
Standard
PRESSURE RANGES:
• From 0-3 through 0-100 psig
(See ordering guide.)
ACCURACY:
• From
±0.1%
FSO (RSS) to
±0.5%
FSO (RSS)
(See specifications & ordering guide.)
with Option LJ
tapered inlet with
stand off plate
ORDERING GUIDE
Ordering: Specify model, and pressure range and indicate modifications or
accessories required.
Use the following codes to identify desired item. Example 313L-B-PZ-LJ
MODEL
SERIES
RANGE
OPTIONS
MODEL
313L 4-20mA
SERIES
B
±0.5%
FSO (RSS)
C
±0.2%
FSO (RSS)
D
±0.1%
FSO (RSS)
•/•/•
OPTIONS
AA
None (standard connector)
CZ
Alternate cable length (specify)
ALTERNATE PRESSURE PORT
FH
1/8” NPT (F)
FL
1/8” NPT (M)
LD
Tapered inlet
LJ
Tapered inlet with standoff plate
PRESSURE RANGE
psi
in wc
PG
3
XK
100
PJ
5
XM
150
PL
7.5
XO
200
PN
10
XQ
300
PP
15
PR
20
PO
25
PT
30
PV
50
PX
75
PZ
100
GENERAL
CT
Tefzel jacketed cable
GA
Standardized output to
±0.5%
FSO
GB
Alternate output, pressure units, or full scale
outputs that are non-standard
GE
Improved temperature compensation to
±0.5%
FSO
unless otherwise specified
GG
Alternate calibration signal
GH
Internal calibration resistor set to 100
±0.5%
FSO
unless other wise specified
JH
Remote cable mounted (in-line) zero & span controls. 3’ cable on open
side. Length of cable on closed side as required. (500’ maximum)
GZ
Customer special
Specifications printed on reverse side of this brochure.
GP:50 reserves the right to make product improvements and amendments to the product specification stated throughout this
brochure without prior notification. Please contact the factory on all critical dimensions and specifications for verification.
TOPE Co., Ltd.
Tel. (02) 8228-0658 • Fax. (02) 8228-0659 • E-mail: tope@ms1.hinet.net • Website: www.sensor.com.tw
SL5B-313L.02C
Proteus simulation problem
Because I am still waiting for the device, I want to use proteus to do the simulation, but I found that some devices cannot be found. Is there a place where I can download the component library?...
kay0821 MCU
MIF file generation tool, I found it myself, please take a look
You can view the spectrum, generate four basic waveforms, and draw your own waveforms...
zhangkai0215 FPGA/CPLD
What harmful effects does X-ray have on the human body? What protective measures should be taken?
1) When an organism receives X-ray irradiation, biological effects are produced, which destroy normal tissue cells and cause biological damage. 2) Protection should be strengthened mainly from the fol...
dtcxn Medical Electronics
About the work of single chip microcomputer
I hope to find a job related to single chip microcomputer in Zhenjiang, phone number 15050212911...
sunyutang198802 Talking about work
Digital tube segment calculation program
This is a program for calculating the digital tube level found on the Internet. It may be helpful for beginners, but experts should not bother....
wxc74 MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2738  1812  245  2482  769  56  37  5  50  16 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号