UM10-4830-FD2 Overview

UM4830 MAT 10M QD CABLE, FD2

Safety mats & Area guarding
Um Series
Universal Safety mat System
UM
Rev. 5.11
heavy-Duty four-Wire Presence Sensing mats
with integrated (non-removable) cable,
category 3 controllers, and Perimeter trim
System
• When UM series mats are combined with an MC3, MC4 or MC6
controller (with complete diagnostics), the result is a system
that meets the standard EN 1760-1:1998 and is entitled to
display the CE mark. See below for an overview of the various
components.
mat
• Activation force: 30 kg (66 lb.) per ANSI/RIA 15.06-1999,
ISO 13856-1:2001, ANSI B11.19-2003, and CSA Z432-04
• Conductive plates: 24 gauge galvanealed sheet steel
• Contact yield strength in excess of 20,000 lb./sq. in.; Fork lift
traffic of 12,000 lb.
• Mat housing cross section: 13.5 mm (0.54 in.)
• PVC black or yellow covering materials (other colors available
on request)
• Durometer of 80 (±3) shore A
• Single-piece molded construction
• Mat flammability self extinguishing, meets UL94VO
• IP67 rated
• Operating temperature -37 to 66°C (-35 to 150°F)
• Mat cable: 18-gauge, 4-conductor, 16-strand, 300 VAC
• Cable length: Standard 5 m (16 ft.), Optional 10 m (32 ft.)
controllers
• Safety category 3 device
• DIN-rail mount (MC3)
• NEMA controllers (MC4, MC6)
• 24 VDC or with universal power supply 100 to 240 VAC
trim
• Two-part perimeter and joining trim simplifies installation and
provides a custom appearance
• Aluminum base surrounds mat, the safety yellow PVC cover
secures mat in place, an aluminum cover that is installed in
place of the PVC cover is also available
• Two-part active joining trim joins multiple mats together
• Molded inside and outside corners available as an option
f
r
C
US
Description
An Omron STI Universal Mat system (UM series mat combined
with an MC3, MC4 or MC6) offers a simple method for guarding
personnel around hazardous machines. A Universal Mat system
offers freedom, flexibility, and reduced operator fatigue when
compared with traditional guarding methods such as interlocked
fences, pullback restraints or perimeter barriers.
Full visibility of and access to the work area is maintained. There
is no need to worry about personnel forgetting to replace mechani-
cal barriers or close gates.
how the System Works
The operation of a Universal Mat system is easy to understand.
The mat is a simple, normally open switch. When a specified
minimum weight is applied to the mat the "switch" closes. This
sends a signal to the controller which, in turn, sends a stop signal
to the guarded machine.
Each mat presents four wires to the controller. This provides the
redundancy required to monitor the wiring for open circuits due to
incorrect wiring or physical damage to the wires.
In order to meet many national safety regulations, Omron STI
offers trim to secure the mat to the floor so that it cannot be easily
relocated and therefore become ineffective.
f2
OmrOn Scientific technOlOgieS, inc.
USA
Tel. 1/888/510-4357
canada
Tel. 1/866/986-6766
For the Latest Information
On the Internet:
www.sti.com
Where do nanometer measurement current errors come from?
Measuring low currents requires an understanding of the various potential error sources [1] that can cause undesirable measurement errors [2] . Two particularly common sources of error that affect mea...
Jack_ma Test/Measurement
Unable to connect to EBOOT
INFO: *** Device Name 'MyEboot111111000000' *** INFO: Using static IP address 192.168.0.5. INFO: Using subnet mask 255.255.255.0. +EbootSendBootmeAndWaitForTftp Sent BOOTME to 255.255.255.255 Sent BOO...
hc1990 Embedded System
for(i=0;i<120;i++)---What does i mean? Why did the LED stay on after changing from 120 to 500?
for(i=0;i120;i++)---What does i mean? Why is the LED always on after changing from 120 to 500?...
QWE4562009 51mcu
Show the process of WEBENCH design + high-pass filter
1.2. Set the cutoff frequency3. Select the linear phase filter 4. Generate the schematic5. SimulateSINStep responsepdf document...
nwx8899 Analogue and Mixed Signal
Alas, a shabby homemade fishing rod bag on a hot day
Alas, a shabby fishing rod bag made on a hot day. I made a rougher one before, but the fabric was too flimsy, so there was a hole in it. I was too lazy to fix it, and finally lost a short fishing rod ...
wangfuchong Talking
Does WINCE support LCD with I80 interface?
The I80 interface has only 16-bit data lines, read and write valid, RS (the rising edge of the command/data selection signal indicates that the 16-bit data line is the command code, and the falling ed...
guojiang139858 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2603  1860  2784  1454  1456  53  38  57  30  16 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号