ZWS300BAF12/L

Description
AC/DC CONVERTER 12V 300W
CategoryPower/power management   
File Size504KB,2 Pages
ManufacturerTDK-LAMBDA
Environmental Compliance
Download Datasheet Parametric View All

ZWS300BAF12/L Overview

AC/DC CONVERTER 12V 300W

ZWS300BAF12/L Parametric

Parameter NameAttribute value
typeopen framework
Number of outputs1
Voltage - input85 ~ 265 VAC
Voltage - Output 112V
Voltage - Output 2-
Voltage - Output 3-
Voltage - Output 4-
Current - Output (maximum)25A
Power (W)300W (336W forced air cooling)
applicationITE (Business)
Voltage - Isolation3kV
efficiency89%
Operating temperature-10°C ~ 70°C (with derating)
characteristicAdjustable output, DC input capability, load sharing, PFC, universal input
Installation typeBase installation
size/dimensions7.09" long x 3.31" wide x 1.65" high (180.0mm x 84.0mm x 42.0mm)
Minimum load required-
ApprovalCE,cURus,TUV
ZWS300BAF Series
300W Single Output, Convection Cooled Power Supplies
Features
Universal Input (85 - 265VAC)
Power Factor Corrected
Convection cooling (300W) or Forced Air (336-338W)
Five year warranty
Less than 0.5mA earth leakage current
Key Market Segments & Applications
Specifications
Model
Input Voltage
Input Current
Inrush Current
(1)(2)
Power Factor
Leakage Current
Off Load Power Draw
Temperature Coefficient
Overcurrent Protection
(3)
Overvoltage Protection
Hold Up Time (Typ)
(1)
Efficiency
(1)
Remote On/Off
Operating Temperature
12V & 15V Models
Operating Temperature
24V, 36V & 48V Models
Storage Temperature
Humidity (non condensing)
Cooling
Withstand Voltage
V
A
A
-
mA
W
%/°C
-
V
ms
%
-
°C
°C
ZWS300BAF
85-265VAC (47-63Hz), 120-370VDC
(5)
3.7 / 1.9 (Convection cooled rating)
15 / 30
0.97 at 100VAC, 0.93 at 200VAC, Meets EN61000-3-2
0.5mA Max. Typically 0.2mA (100VAC), 0.4mA (230VAC)
Typically 0.1W at 100VAC, 0.5W at 200VAC, 0.8W at 265VAC when unit is in inhibit
<0.02%/°C
>116% of convection cooled rated output current (>105% for 12V model)
12V: 13.8-16.2V, 15V: 17.3-20.3V, 24V: 28.8-33.6V, 36V: 41.4-48.6V, 48V: 55.2-64.8V
18ms at 100VAC input (Convection cooled rating)
12 & 15V models: 86 / 89%, 24V, 36V & 48V models: 88 / 91% (Convection cooled rating)
Optional, see instruction manual
Convection: -10°C to +70°C, derate linearly to 40% load from 40°C to 70°C
1.4m/s Airflow: -10°C to +70°C, derate linearly to 60% load from 50°C to 70°C
Convection: -10°C to +70°C, derate linearly to 40% load from 45°C to 70°C
0.7m/s Airflow: -10°C to +70°C, derate linearly to 60% load from 50°C to 70°C
1.4m/s Airflow: -10°C to +70°C, derate linearly to 70% load from 60°C to 70°C
-30 to +75°C
Operating: 30 - 90%RH, Storage: 10 - 90%RH
Convection or forced air
Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA), Output to Ground 500VAC
(20mA) for 1 min.
>100M at 25°C & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s
2
constant X, Y, Z 1 hour each
< 196.1 m/s
2
UL60950-1, CSA60950-1, EN60950-1, EN50178 OV II, CE Mark
EN55011/EN55022-B, FCC Class B, VCCI-B
EN61000-4-2 (lvl2, 3), -3 (lvl 3), -4 (lvl 3), -5 (lvl 3, 4), -6 (lvl 3), -8 (lvl 4), -11; EN61000-6-2
540g (open frame)
3.31 x 1.65 x 7.09” (84 x 42 x 180) open frame
Five Years
°C
%RH
-
-
Isolation Resistance
-
Vibration (non operating)
-
Shock
-
Safety Agency Certifications
-
(4)
Conducted & Radiated EMI
-
Immunity
-
Weight (Typ)
g
Size (WxHxD)
in (mm)
Warranty
yrs
Notes:
(1) 100 / 200VAC Input
(2) 25°C ambient (cold start)
(3) Avoid prolonged operartion in overload
(4) Forced air rating: Class A radiated
(5) Safety certified for AC input only
1-800-526-2324 • www.us.tdk-lambda.com/lp/
109
Disclaimer: us.tdk-lambda.com/lp/legal.htm
Urgent help regarding the electricity meter.
I am now mainly working on the improvement of electric energy meters. The overall framework is in the attachment. It is converted from the product of voltage and current to power, but it can be consid...
我爱影魔 Analog electronics
EEWORLD University ---- TI Online Training: Application of Low-Power Wi-Fi in Smart Home
TI online training: Application of low-power Wi-Fi in smart home : https://training.eeworld.com.cn/course/4089...
hi5 Talking
【CC1352P Review】Summary
LAUNCHXL_CC1352P1 The "luxury" materials used in this board lie in the debugger part on the board (the MCU's periphery is only equipped with a SPI Flash, in addition to the necessary crystal oscillato...
cruelfox RF/Wirelessly
Use of MSP430 serial port
Functional description: Two virtual terminals, 430 receives character input from B1 and returns the character to B1, and also sends the character to B2 via infrared. Infrared is modulated by 555 timer...
qinkaiabc Microcontroller MCU
A classic joke from a foreigner (it doesn’t matter, the translation below is more exciting)
1. I asked God for a bike, but I know God doesn't work that way. So I stole a bike and asked for forgiveness. 2. I want to die peacefully in my sleep, like my grandfather.. Not screaming and yelling l...
银座水王 Talking
【Low Power】FPGA Basic Circuit-Analog Circuit Basics
A comprehensive introduction to the basic knowledge of FPGA circuits - analog circuits. [[i] This post was last edited by dream_byxiaoyu on 2011-11-12 12:38 [/i]]...
dream_byxiaoyu FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2567  2176  2251  1874  1577  52  44  46  38  32 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号