EEWORLDEEWORLDEEWORLD

Part Number

Search

4230-T120-K0DU-63A

Description
CIR BRKR THERM 63A 480VAC/125VDC
CategoryCircuit protection   
File Size1MB,12 Pages
ManufacturerE-Switch
Websitehttp://www.e-switch.com
Download Datasheet Parametric View All

4230-T120-K0DU-63A Online Shopping

Suppliers Part Number Price MOQ In stock  
4230-T120-K0DU-63A - - View Buy Now

4230-T120-K0DU-63A Overview

CIR BRKR THERM 63A 480VAC/125VDC

4230-T120-K0DU-63A Parametric

Parameter NameAttribute value
Circuit breaker typeThermomagnetic
Rated current63A
Rated voltage - AC480V
Rated voltage - DC125V
Number of poles2
Actuator typepress slice
illuminationnone
Lighting voltage (nominal)-
Installation typeDIN rail
Thermal-magnetic Miniature Circuit Breaker 4230-T...
Description
Single pole and multipole thermal-magnetic miniature circuit breakers
(MCBs) in accordance with EN 60947-2, UL 1077 and UL 489 for
DIN rail mounting, with toggle actuation, visual status indication and
high rupture capacity. A positively trip-free snap action mechanism
ensures reliable switching behaviour. A range of trip characteristics
and add-on modules allow a great variety of applications.
Typical applications
Protection of cables, motors, generators and transformers, thyristors
and silicon rectifiers. Protection of computers and their peripheral
equipment, industrial process control systems, telecommunications
equipment, power supplies.
UL 489 version
4230-T...
1
IEC/EN60947-2 & UL1077 version
Technical Data
Voltage rating and current rating range
to IEC/EN 60947-2
1-pole: AC 240 V; 1 A…63 A;
2, 3, 4-pole: AC 415 V, 1 A…63 A;
1-pole: DC 80 V, 1 A...63 A
2-pole: (2 poles connected in series)
DC 125 V, 1...63 A
1-pole: AC 277 V; 1 A…63 A;
2, 3, 4-pole: AC 480Y/277 V, 1 A…63 A;
1-pole: DC 60 V; 1 A...63 A;
2-pole (2 poles connected in series):
DC 125 V; 1 A...63 A;
1-pole: AC 120 V; 1A…63 A;
2, 3-pole: AC 240 V, 1 A…63 A;
1-pole: AC 277 V; 1 A…32 A;
2, 3-pole: AC 480Y/277 V; 1 A…32 A;
1-pole: DC 60 V; 1 A…63 A;
2-pole (2 poles connected in series);
DC 125 V; 1 A…63 A;
20,000 cycles
6,000 cycles
Technical Data
Rupture capacity
to IEC/EN 60947-2 (Ics)
to IEC/EN 60947-2
(Icu)
to UL 489
to UL1077
Number of
poles
1-pole
1-pole
2-, 3-,
4-pole
1-pole
2-pole in
series
Un
AC 240 V
AC 277 V
AC 480 V
DC 60 V
DC 125 V
In
AC 7,500 A / DC 10,000 A
AC/DC 10,000 A
AC/DC 10,000 A
TC
1
1
1
1
1
OL
1
0
1
0
0
SC
7.5 kA, U1
5 kA, U1
5 kA, U1
7.5 kA, U1
7.5 kA, U1
to UL 1077
to UL 489
1...63 A
1...63 A
1...63 A
1...63 A
1...63 A
Typical life
Mechanically
Electrically
Insulation coordination
Degree of protection
Vibration (sinusoidal)
test to IEC 60068-2-6,
test Fc
Shock, test to
IEC 60068-2-27, test Ea
Corrosion, test to IEC
60068-2-11, test Ka
Humidity, test to IEC
60068-2-78, test Cab
Terminals
6 kV/3 (reinforced insulation
at operating area)
IP20
± 0.38 mm (10–57 Hz), 5 g
(57–500 Hz)
10 frequency cycles per axis
30 g (11 ms)
96 hrs in 5% salt mist
48 hours at 95% RH,
temperature +40°C
screw terminals
Vertical connection possible
by means of busbars
2 Nm max.
≤35 mm²
-35°C...+ 70°C
rail mounting
approx. 116 g per pole (EN 60947-2/
UL 1077) approx. 131 g per pole
(UL 489)
Approvals
Approval
authority
TÜV
Standard
IEC/EN
60947-2
Rated voltage
AC 240/415 V
DC 80 V
DC 125 V
AC 480Y/277 V
DC 60 V
DC 125 V
AC 240 V
AC 480Y/277 V
DC 60 V
DC 125 V
Current ratings
1...63 A
1...63 A (1-pole)
1...63 A (2 poles in
series)
1...63 A
1...63 A (1-pole)
1...63 A (2 poles in
series)
1...63 A
1...32 A
1...63 A (1-pole)
1...63 A (2 poles in
series)
UL
UL 1077 /
CSA-C22.2
No. 235
UL 489 /
CSA-C22.2
No. 5
UL
Tightening torque
Cable cross section
Ambient temperature:
Mounting
Mass
1638
www.e-t-a.de
1
How can I use C language to implement the following logical function?
I want the control system to make the light connected to P3^4 flash within the first 5 seconds for system self-check. It also requires that when P1^3 is set to 1, P3^1 is also set to 1. When P3^1 last...
轻焰一束 MCU
Hiring embedded hardware engineers
Headhunting position [Shanghai] Job responsibilities: 1. Analyze sample solutions, design and produce PCB, bill of materials; 2. Responsible for the design and development of hardware systems based on...
ff318421749 Recruitment
I would like to ask about the problem of packaging multiple sensor data into one data
I would like to ask: How can I pack the data from multiple sensors into one piece of data and send it? For example, if the temperature measured by temperature measuring device A is 25 degrees Celsius,...
似水ai流年 51mcu
Is there any way to use the MIBSPI port of TMS570 as GIO?
I was designing and the IO was not enough, so I used MIBSOI as a normal IO. Is there anyone who does this? ? Come out and share...
wdy3585 Microcontroller MCU
Program display part of motor speed measurement system based on microcontroller control
#include #include #define uint unsigned int #define uchar unsigned char sbit E=P2^7; sbit RW=P2^6; sbit RS=P2^5; sbit PWM=P1^0; sbit fz=P1^1; sbit key=P2^ 0; sbit p33=P3^3; uchar count; uchar N=0; uch...
yaoliming4325 51mcu
Can the 51 development board be used for PIC development?
PIC18, all have 40 pins, I don't know if they can be used universally, I use this for self-study....
zxpla Microchip MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1252  2633  1471  1564  264  26  54  30  32  6 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号