RAC150-12SG/OF

Description
CONV AC/DC 120W (150W FORCED AIR
CategoryPower/power management   
File Size881KB,8 Pages
ManufacturerRECOM Power GmbH
Websitehttps://www.recom-power.com/
Environmental Compliance
Download Datasheet Parametric Compare View All

RAC150-12SG/OF Overview

CONV AC/DC 120W (150W FORCED AIR

RAC150-12SG/OF Parametric

Parameter NameAttribute value
typeopen framework
Number of outputs1
Voltage - input90 ~ 264 VAC
Voltage - Output 112V
Voltage - Output 2-
Voltage - Output 3-
Voltage - Output 4-
Current - Output (maximum)12.5A
Power (W)125W (150W forced air cooling)
applicationITE (Business)
Voltage - Isolation3kV
efficiency91%
Operating temperature-30°C ~ 70°C (with derating)
Installation typeBase installation
size/dimensions4.00" long x 2.00" wide x 0.94" high (101.6mm x 50.8mm x 24.0mm)
Minimum load requirednone
ApprovalCE,cURus
Features
Regulated
Converters
Description
Universal Input 90-264VAC
Efficiency 91%
Short Circuit And Over Voltage Protected
Active PFC Function, PF>0.95
Power Indicator LED
UL, CE Marked (CB Report)
Conformal Coated Product
RECOM Connector Set Available
AC/DC Converter
RAC150-G
150 Watt
3
4“ x 2“
Open Frame or
Enclosed Case
3Y
wa
EAR
The RAC150 series are cost-efficient 150 Watt AC/DC power supplies in a standard 2”x4” footprint with
a universal input range of 90-264VAC for worldwide usage. They are built to deliver up to 125 Watt
with natural air convection for use in tight, space-critical housings with low available airflow. UL and
CE marks with CB-reports include the new 62368 safety standard as well as the usual 60950 safety
standard. The RAC150 series offers tightly regulated 12V, 24V and 48VDC outputs with 3kVAC isolation
and Class B EMC certifications and come with a three year warranty.
rranty
Selection Guide
Part
Number
RAC150-12SG
(4)
RAC150-24SG
(4)
RAC150-48SG
(4)
Input
Voltage Range
[VAC]
90-264
90-264
90-264
Output
Voltage
[VDC]
12
24
48
max. Output
Current
(1)
[mA]
12500
6250
3125
typ.
Efficiency
(2)
[%]
91
91
91
Max. Capacitive
Load
(3)
[µF]
2000
1000
500
Notes:
Note1: With forced air cooling, refer to derating graph.
Note2: Typ. efficiency is tested @ 230VAC and full load.
Note3: Max. cap load is tested @ 90-264VAC and full resistive load.
Model Numbering
RAC150-__SG/_
Output Voltage
Single
Case Option
(4)
Notes:
Note4: add suffix “OF” for open frame version
add suffix “ENC” for enclosed version
E196683
UL62368-1 Certified
CAN/CSA C22.2 No. 62368-1-14 Certified
UL60950 Certified
CAN/CSA C22.2 N.60950-1-07 Certified
IEC/EN60950-1 Certified
EN55022/55024
FCC Part 15
CB Report
Ordering Examples:
RAC150-24SG/OF, 24Vout Single, open frame version.
RAC150-12SG/ENC, 12Vout Single, enclosed version.
Specifications
(measured @ ta = 25°C, nominal input voltage, full load otherwise noted)
BASIC CHARACTERISTICS
Parameter
Output Power
Internal Input Filter
Input Voltage Range
Input Current
Inrush Current
Input Frequency Range
continued on next page
www.recom-power.com
REV.: 3/2017
Condition
90-264VAC, with forced airflow
230VAC, natural convection
115VAC, natural convection
90-115VAC
Min.
Typ.
Max.
150W
125W
120W
refer to derating guidlines (PA-4)
Pi type
90VAC
230VAC
264VAC
2A
40A
60A
47Hz
63Hz
cold start, 115VAC
cold start, 230VAC
PA-1

RAC150-12SG/OF Related Products

RAC150-12SG/OF RAC150-24SG/OF RAC150-48SG/OF RAC150-12SG/ENC RAC150-48SG/ENC RAC150-24SG/ENC
Description CONV AC/DC 120W (150W FORCED AIR CONV AC/DC 120W (150W FORCED AIR CONV AC/DC 120W (150W FORCED AIR CONV AC/DC 120W (150W FORCED AIR CONV AC/DC 120W (150W FORCED AIR CONV AC/DC 120W (150W FORCED AIR
type open framework open framework open framework closed closed closed
Number of outputs 1 1 1 1 1 1
Voltage - input 90 ~ 264 VAC 90 ~ 264 VAC 90 ~ 264 VAC 90 ~ 264 VAC 90 ~ 264 VAC 90 ~ 264 VAC
Voltage - Output 1 12V 24V 48V 12V 48V 24V
Current - Output (maximum) 12.5A 6.25A 3.125A 12.5A 3.125A 6.25A
Power (W) 125W (150W forced air cooling) 125W (150W forced air cooling) 125W (150W forced air cooling) 125W (150W forced air cooling) 125W (150W forced air cooling) 125W (150W forced air cooling)
application ITE (Business) ITE (Business) ITE (Business) ITE (Business) ITE (Business) ITE (Business)
Voltage - Isolation 3kV 3kV 3kV 3kV 3kV 3kV
efficiency 91% 91% 91% 91% 91% 91%
Operating temperature -30°C ~ 70°C (with derating) -30°C ~ 70°C (with derating) -30°C ~ 70°C (with derating) -30°C ~ 70°C (with derating) -30°C ~ 70°C (with derating) -30°C ~ 70°C (with derating)
Installation type Base installation Base installation Base installation Base installation Base installation Base installation
size/dimensions 4.00" long x 2.00" wide x 0.94" high (101.6mm x 50.8mm x 24.0mm) 4.00" long x 2.00" wide x 0.94" high (101.6mm x 50.8mm x 24.0mm) 4.00" long x 2.00" wide x 0.94" high (101.6mm x 50.8mm x 24.0mm) 4.13" long x 2.44" wide x 1.38" high (105.0mm x 62.0mm x 35.0mm) 4.13" long x 2.44" wide x 1.38" high (105.0mm x 62.0mm x 35.0mm) 4.13" long x 2.44" wide x 1.38" high (105.0mm x 62.0mm x 35.0mm)
Minimum load required none none none none none none
Approval CE,cURus CE,cURus CE,cURus CE,cURus CE,cURus CE,cURus

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 148  1203  902  2652  256  3  25  19  54  6 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号