Features
Regulated
Converters
Description
•
•
•
•
•
•
•
•
Universal Input 90-264VAC
Efficiency 91%
Short Circuit And Over Voltage Protected
Active PFC Function, PF>0.95
Power Indicator LED
UL, CE Marked (CB Report)
Conformal Coated Product
RECOM Connector Set Available
AC/DC Converter
RAC150-G
150 Watt
3
4“ x 2“
Open Frame or
Enclosed Case
3Y
wa
EAR
The RAC150 series are cost-efficient 150 Watt AC/DC power supplies in a standard 2”x4” footprint with
a universal input range of 90-264VAC for worldwide usage. They are built to deliver up to 125 Watt
with natural air convection for use in tight, space-critical housings with low available airflow. UL and
CE marks with CB-reports include the new 62368 safety standard as well as the usual 60950 safety
standard. The RAC150 series offers tightly regulated 12V, 24V and 48VDC outputs with 3kVAC isolation
and Class B EMC certifications and come with a three year warranty.
rranty
Selection Guide
Part
Number
RAC150-12SG
(4)
RAC150-24SG
(4)
RAC150-48SG
(4)
Input
Voltage Range
[VAC]
90-264
90-264
90-264
Output
Voltage
[VDC]
12
24
48
max. Output
Current
(1)
[mA]
12500
6250
3125
typ.
Efficiency
(2)
[%]
91
91
91
Max. Capacitive
Load
(3)
[µF]
2000
1000
500
Notes:
Note1: With forced air cooling, refer to derating graph.
Note2: Typ. efficiency is tested @ 230VAC and full load.
Note3: Max. cap load is tested @ 90-264VAC and full resistive load.
Model Numbering
RAC150-__SG/_
Output Voltage
Single
Case Option
(4)
Notes:
Note4: add suffix “OF” for open frame version
add suffix “ENC” for enclosed version
E196683
UL62368-1 Certified
CAN/CSA C22.2 No. 62368-1-14 Certified
UL60950 Certified
CAN/CSA C22.2 N.60950-1-07 Certified
IEC/EN60950-1 Certified
EN55022/55024
FCC Part 15
CB Report
Ordering Examples:
RAC150-24SG/OF, 24Vout Single, open frame version.
RAC150-12SG/ENC, 12Vout Single, enclosed version.
Specifications
(measured @ ta = 25°C, nominal input voltage, full load otherwise noted)
BASIC CHARACTERISTICS
Parameter
Output Power
Internal Input Filter
Input Voltage Range
Input Current
Inrush Current
Input Frequency Range
continued on next page
www.recom-power.com
REV.: 3/2017
Condition
90-264VAC, with forced airflow
230VAC, natural convection
115VAC, natural convection
90-115VAC
Min.
Typ.
Max.
150W
125W
120W
refer to derating guidlines (PA-4)
Pi type
90VAC
230VAC
264VAC
2A
40A
60A
47Hz
63Hz
cold start, 115VAC
cold start, 230VAC
PA-1
AC/DC Converter
Specifications
(measured @ ta = 25°C, nominal input voltage, full load otherwise noted)
Parameter
Rise Time
Hold-up Time
Minimum Load
Internal Operating Frequency
+70°C
Output Ripple & Noise
-30°C
Power Factor
12VDC
24VDC
48VDC
12VDC
24VDC
48VDC
115VAC
230VAC
RAC150-G
Series
Condition
115VAC/230VAC
115VAC / 230VAC
100% load
50% load
6ms
20ms
0%
132kHz
150mVp-p
240mVp-p
360mVp-p
300mVp-p
480mVp-p
720mVp-p
0.98
0.95
Min.
Typ.
Max.
50ms
RAC150-12SG
RAC150-12SG
RAC150-12SG
RAC150-24SG
RAC150-24SG
RAC150-24SG
Efficiency vs. Load
100
80
100
80
100
80
100
80
Efficiency [%]
Efficiency [%]
60
40
20
0
60
40
20
0
2 0
90VAC
115VAC
230VAC
264VAC
90VAC
115VAC
230VAC
264VAC
60
40
20
0
Efficiency [%]
60
40
20
0
90VAC
115VAC
230VAC
264VAC
90VAC
115VAC
230VAC
264VAC
0
4 2
6 4
8 6
10 8
12.5
10
12.5
0
1
0
2 1
3 2
4 3
5 4
6 5 6.25 6
6.25
Output Current [A]
Output Current [A]
Output Current [A]
Output Current [A]
Output Power vs. Input Voltage
140
120
Efficiency vs. Input Voltage
100
80
(@ full load)
Output Power [W]
Efficiency [%]
100
80
60
40
20
natural air /OF
natural air /ENC
60
40
20
0
90
100
115
180
230
264
0
90 100 120 140
160
180 200
220
240
264
Input Voltage [VAC]
PA-2
continued on next page
REV.: 3/2017
Input Voltage [VAC]
www.recom-power.com
AC/DC Converter
Specifications
(measured @ ta = 25°C, nominal input voltage, full load otherwise noted)
REGULATIONS
Parameter
Output Accuracy
Load Regulation
Line Regulation
Transient Response
RAC150-G
Series
Condition
-30°C to +70°C
-30°C to +70°C, 0%-100% load
-30°C to +70°C
-30°C to +70°C
0.04
0.03
0.02
0.01
0
Value
±2.0% max.
±0.2% typ.
±0.1% typ.
±5.0% Vout max.
200µs max.
25% load step change
recovery time
Normalized Output Regulation
Regulation [%]
90VAC
115VAC
230VAC
264VAC
-0.01
-0.02
-0.03
-0.03
0
20
40
60
80
100
Output Load [%]
PROTECTIONS
Parameter
Input Fuse
Short Circuit Protection
Over Voltage Protection (OVP)
Over Voltage Category
Class of Equipment
Isolation Voltage
(5)
Type
internal
below 100mW
105%-150% of Vout nominal
Value
T3.15A
continuous, Hiccup Mode, auto recovery
Latch OFF
OVC II
Class
I
3kVAC
1.5kVAC
0.5kVDC
3300pF typ.
10MW min.
0.25mA max.
reinforced
tested for 1 minute
I/P to O/P
I/P to FG
O/P to FG
Isolation Capacitance
Isolation Resistance
Leakage Current
Insulation Grade
Notes:
Note5: For repeat Hi-Pot testing, reduce the time and/or the test voltage
I/P to O/P; I/P to FG; O/P to FG
240VAC, 63Hz
ENVIRONMENTAL
Parameter
Operating Temperature Range
Temperature Coefficient
Operating Humidity
Operating Altitude
(6)
Pollution Degree
Conformal Coating
Shock
Vibration
MTBF
MIL-HDBK-217F G.B.
+25°C
natural convection (125W)
forced cooling (150W)
non-condensing
Condition
with derating (see graph on next page)
Value
-30°C to +70°C
±0.02%/°C
20% - 90% RH
5000m
PD2
conformal coated product
20G, 11ms, 3 times for X,Y,Z axis
10-500Hz, 3G, 10min. for each, 6cycles for each X,Y,Z
100 x 10
3
hours
200 x 10
3
hours
continued on next page
www.recom-power.com
REV.: 3/2017
PA-3
AC/DC Converter
Specifications
(measured @ ta = 25°C, nominal input voltage, full load otherwise noted)
RAC150-G
Series
Notes:
Note6: Recognized by UL for safe operation up to 5000m. High altitude operation may impact the performance and lifetime.
Contact RECOM tech support for advice
Derating Graph
Enclosed
150
122
125
@ 230VAC, horizontal mount
150
125
Open Frame
Output Power [W]
Output Power [W]
100
80
75
50
25
100
75
50
25
70
2.5m/s
1.5m/s
0.8m/s
0.4/ms
natural convection
2.5m/s
1.5m/s
0.8m/s
0.4/ms
natural convection
0
-30 -20 -10
0
10
20
30
40
50
60
70
80
0
-30 -20 -10
0
10
20
30
40
50
60
70
80
Ambient Temperature [°C]
Ambient Temperature [°C]
@ 115VAC, horizontal mount
150
125
100
75
50
35
25
Enclosed
150
125
100
75
60
50
25
2.5m/s
1.5m/s
0.8m/s
0.4/ms
natural convection
Open Frame
118
120
Output Power [W]
Output Power [W]
2.5m/s
1.5m/s
0.8m/s
0.4/ms
natural convection
0
-30 -20 -10
0
10
20
30
40
Ambient Temperature [°C]
45
50
60
70
80
0
-30 -20 -10
0
10
20
30
Ambient Temperature [°C]
40 50
42
60
70
80
150W
2.5
2.25
2.0
1.75
1.5
1.25
1.0
0.75
0.5
0.25
0
20
still air
Required Airflow
2.5
2.25
2.0
1.75
1.5
1.25
1.0
0.75
0.5
0.25
0
20
115VAC
230VAC
120W
115VAC
230VAC
Airflow [m/s]
Airflow [m/s]
still air
30
40
50
60
70
30
40
50
60
70
Ambient Temperature [°C]
Ambient Temperature [°C]
<0.1m/s = still air
0.1 - 0.2m/s = natural convection
PA-4
REV.: 3/2017
www.recom-power.com
AC/DC Converter
Specifications
(measured @ ta = 25°C, nominal input voltage, full load otherwise noted)
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Information Technology Equipment, General Requirements for Safety
E196683-A2
Audio/Video, information and communication technology equipment - Safety requirements
Audio/video, information and communication technology equipment - Safety requirements
(CB Scheme)
Audio/video, information and communication technology equipment - Safety requirements
(CB Scheme)
RoHS2
16BCS07071821
16BAS07018 11
RAC150-G
Series
Report / File Number
Standard
UL60950-1, 2nd Edition, 2014
CSA C22.2 No. 60950-1-07, 2nd Ed. 2014
UL62368-1, 2nd Edition, 2014
CSA C22.2 Nr. 62368-1-14, 2nd Ed. 2014
IEC62368-1, 2nd Edition, 2014
EN62368-1, 2014
IEC60950-1, 2nd Edition + AM2, 2013
EN60950-1, 2nd Edition + A2:2013
RoHS 2011/65/EU + AM2015/863
EMC Compliance
Information technology equipment - Immunity characteristics - Limits and methods of measurement
Information technology equipment - Immunity characteristics - Limits and methods of measurement
Limitations on the amount of electromagnetic intererence allowed from digital and electro-
nic devices
ESD Electrostatic discharge immunity test
Radiated, radio-frequency, electromagnetic field immunity test
Fast Transient and Burst Immunity
Surge Immunity
Immunity to conducted disturbances, induced by radio-frequency fields
Voltage Dips and Interruptions
Limits of Harmonic Current Emissions
Voltage Fluctuations and Flicker in Public Low-Voltage Systems <=16A per phase
Conditions
16EAS07018 11
Standard / Criterion
EN55022, Class B
EN55024, 2015
47 CFR FCC Part 15, Subpart, Class B
±8kV Air; ±4kV Contact
3V/m
AC Power Port: ±1kV
AC Power Port: L-N ±1kV
L-PE & N-PE ±2kV
AC Power Port: 3V
Dips: >95% reduction
Interruption: >95%
EN61000-4-2, Criteria B
EN61000-4-3, Criteria A
EN61000-4-4, Criteria B
EN61000-4-5, Criteria B
EN61000-4-6, Criteria A
EN61000-4-11, Criteria B
EN61000-4-11, Criteria C
EN61000-3-2, Criteria A
EN61000-3-3
DIMENSIONS and PHYSICAL CHARACTERISTICS
Parameter
Material
Package Dimension (LxWxH)
Package Weight
Type
PCB
Case/Baseplate
OF -version
ENC-version
OF -version
ENC-version
Value
FR4 (UL94-V0)
Aluminium
101.6 x 50.8 x 30.0mm
105.0 x 62.0 x 35.0mm
200g
265g
continued on next page
www.recom-power.com
REV.: 3/2017
PA-5