PZ-30
PRESSURE INDICATORS
■
STANDARD SPECIFICATIONS
Unless otherwise specified, the specs are defined at an ambient temperature of 25±5 °C and excitation voltage of 24 V DC.
Item
Operating temp. range
Model number
°C
%RH
°C
g
PZ-30
−
10 ~ 50
35 ~ 85
IP40
−
20 ~ 70
Approx. 80 (Including 2 m cable)
100 MΩ minimum
500 V DC 1 minute
10.8 ~ 30 V DC
(
ncluding ripple percentage
)※
50 mA maximum
1 ~ 5 V (V) / 4 ~ 20 mA (I)
General specifications
Imput
Operating humidity
Protection grade
Storage temp.
Net weight
Insulation resistance
Dielectric strength
Supply voltage
Consumption current
Input signal
Input impedance
No. of digit
Display element
Display cycle
Negative pressure display
Display accuracy
Thermal error
Resolution
Output status
Switching capacity
Residual voltage
kΩ
10 kΩ (V) / 250
Ω
(I)
3
LED
Approx. 4 times/s
“–” LED is ON
±
1 %F.S. (Without sensor's error)
±
0.5 % (0 ~ 50 °C, Reference temp. 25 °C)
1 count
NPN/PNP
2-point output (Transistor, Open collector output)
30 V DC 100 mA maximum
1.2 V maximum (NPN), 2.2 V maximum (PNP)
0 ~ 300 counts
Adjustable
±
0.2 %F.S.
±
1 count
With pretection function
Approx. 5 ms (“F – 0”) (Selectable 5 ms ~ 2.5 s)
±
0.5 %F.S. (0 ~ 50 °C, Refernce temp. 25°C)
Output 1 (Green LED), Output 2 (Red LED) Lighted when output is ON.
Switch
Analog output
Display
Hysteresis setting
Repeatability
Short circuit protection
Response
Thermal error
State indication
Voltage output
Current output
1~5V
4 ~ 20 mA(Load
resistance 500Ωmaximum)
※
When analog current output type of PZ30 is chosen or when a sensor of current output type is connected, supply voltage is 24 V DC
±
10%
■
ENVIRONMENTAL CHARACTERISTICS
Test item
Vibration
Shock
Moisture resistance
EMC
Test conditions
10 ~ 500 Hz, 98.1 m/s
2
or 1.5 mm P-P, 3 directions for 2 hours each
490 m/s
2
, 3 directions for 3 times each
40 °C, 90 ~ 95 %RH, 240 hrs.
EMI : EN55011: 2007, A2 : 2007 Group 1, class B
EMS : EN61326-1: 2006 Table 2
Pressure indication, switch operating points
and analog output variation :
±
1 %F.S. maximum each after test
Permissible change
Pressure indication, switch operating pressure and
analog output :
±
5 %F.S. maximum during test
PRESSURE INDICATORS
PZ-30
■
INTERNAL ELECTRICAL SCHEMATICS
Voltage analog output
・
Current input NPN output
・
Current input PNP output
1
2
LED Indicator
Power
B
LED Indicator
1
2
Power
B
V+
¡
〉〉
Is
™
〉〉
£
〉〉
Main circuit
Load Load
V+
¡
〉〉
Is
™
〉〉
£
〉〉
Main circuit
S.Output1
S.Output2
Load Load
Sensor
S.Output1
S.Output2
Common
A.Output
Sensor
Com
Com
Common
A.Output
LED
Pressure indication
LED
Pressure indication
・
Voltage input NPN output
・
Voltage input PNP output
1
2
LED Indicator
Power
B
LED Indicator
1
2
Power
B
V+
¡
〉〉
Vs
™
〉〉
£
〉〉
Main circuit
Load Load
V+
¡
〉〉
Vs
™
〉〉
£
〉〉
Main circuit
S.Output1
S.Output2
Load Load
Sensor
S.Output1
S.Output2
Common
A.Output
Sensor
Com
Com
Common
A.Output
LED
Pressure indication
LED
Pressure indication
※
When connecting the 2-wire type of current output sensors, please do not connect the 3 (Com.) terminal.
Current analog output
・
Current input NPN output
・
Current input PNP output
LED Indicator
1
2
LED Indicator
1
2
Power
B
V+
¡
〉〉
Is
™
〉〉
£
〉〉
Common
LED
Pressure indication
Main circuit
A.Output
S.Output1
S.Output2
Load
Load
Power
B
V+
¡
〉〉
Is
™
〉〉
£
〉〉
Main circuit
S.Output1
S.Output2
A.Output
Load
Load
Sensor
Sensor
Com
Com
Common
LED
Pressure indication
・
Voltage input NPN output
LED Indicator
1
2
・
Voltage input PNP output
1
2
LED Indicator
Power
B
Power
B
V+
¡
〉〉
Vs
™
〉〉
£
〉〉
Main circuit
A.Output
Load
Load
V+
¡
〉〉
Vs
™
〉〉
£
〉〉
Main circuit
S.Output1
S.Output2
A.Output
Load
Load
Sensor
S.Output1
S.Output2
Common
Sensor
Com
Com
Common
LED
Pressure indication
LED
Pressure indication
※
When connecting the 2-wire type of current output sensors, please do not connect the 3 (Com.) terminal.
PZ-30
PRESSURE INDICATORS
■
ANALOG OUTPUT MODE
Analog output setting : The second figure in triple digits LED indicates
output mode in the initial setting.
Output mode is fixed by rated pressure.
Code
“1”
Analog output
Output mode
R mode (Compound)
−Pr
0
Pr
1V
(4 mA)
(Vzero)
5V
(20 mA)
5V
(20 mA)
“2”
G mode (Positive)
1V
(4 mA)
5V
(20 mA)
1V
(4 mA)
“3”
V mode (Negative)
■
SWITCH OUTPUT MODE
Switch output can be set when blinking red LED indicates (SW2) in the intial setting.
The mode is set at “Separate (H/H), 1” prior to shipment. The mode is initialized at “Separate (L/L), 4” when rated pressure is set at “-12P” or “-12F” (negative pressure).
Output
Mode
Operation
Separate
SW1
Window comparator
Separate
SW2
Window comparator
Separate mode
(HI
operation)
ON
OFF
-Pr
H
H
P1: SW1
P2: SW2
Pr
Window comparator mode
(A
operation)
ON
OFF
P1
-Pr
H
H
P2
Pr
ON
HI
LO
A
B
HI
LO
A
B
S- 1
S- 2
S- 3
S- 4
C- 5
C- 6
C- 7
C- 8
Pressure setting
(Operating point)
Setting 1
(Lower limit) : Setting 1
(Upper limit) : Setting 2
Setting 2
(Lower limit) : Setting 1
(Upper limit) : Setting 2
(LO
operation)
ON
OFF
Pr
H
H
(B
operation)
ON
P1: SW1
-Pr
P2: SW2
OFF
-Pr
P1
H
H
P2
OFF
Pr
P1≦P2 or P1≧P2
H:
Switch hysteresis、
P1=
Setting 1
、
P2=
Setting 2
P1≦P2–2H
Note 1. In the Separate Mode, setting 1 corresponds to SW1, and Setting 2
corresponds to SW2.
Note 2. In the Window Comparator Mode, the minimum value for SW1 and SW2
corresponds to Setting 1 and the maximum value corresponds to Setting 2.
PRESSURE INDICATORS
PZ-30
■
SELECTION OF DISPLAY MULTIPLIER/RATED PRESSURE
Selection of display multiplier
Please set any code when blinking red LED indicates negative
pressure in the initial setting.
Display multiplier is set at “1” (kPa) prior to shipment.
Pressure reference
Pressure unit
Rated pressure range
Setting code
Selection of rated pressure
Please set any code when blinking red LED indicates negative
pressure, SW1, SW2 in the initial setting.
Rated pressure is set at “12P” (0 ~ 100 kPa) prior to shipment.
Due to various reasons, I was unable to complete the task on time this time, and I regrettably missed the grand prize. However, I also saw many things made by masters this time. The creativity and ide...
As shown in the figure above, ch2 (blue) is the waveform of the grid-connected inverter output circuit. The inverter is a grid-connected inverter topology structure isolated by a transformer: the sing...
Recently, there was news that thousands of students in Henan Province smashed and destroyed the school cafeteria and canteen - it was really gratifying. Our school cafeteria is like most canteens in C...
Event details: Click here to learn moreFirst of all, thank you all for participating in and supporting the Pingtouge RVB2601 open source application innovation collection event, including the particip...
The following problem occurs when using Nios: No Nios II target connection paths were located. Check connections and that a Nios II .sof is downloaded. Click refresh connection, but nothing happens? ?...
Question: 1 warning of timing analysis warning [table][tr][td] When doing timing analysis, only one path does not meet the requirement: -0.044 ns 99.56 MHz (period = 10.044 ns) . . . . . . . If I add ...
Today, with the increasing integration of functions, mobile phones can also be used as portable media players (PMP), digital cameras, handheld computers (PDAs), and even global positioning systems ...[Details]
introduction
Throughout the history of automotive lighting, power has always played an important role. Initially, cars only needed headlights to see the road in the dark. Later, other light so...[Details]
Due to the significant increase in electronic devices in automotive and industrial applications, the automotive and industrial markets continue to play an important role in China's electronics in...[Details]
I. Introduction
In the field of power conversion, isolated converters (forward, flyback, and double-ended) with low output DC voltage all use MOSFET as the rectifier device. Since these devi...[Details]
1. Principle of displacement angle sensor
The angle sensor is used to detect angles. It has a hole in its body that fits the LEGO axle. When connected to the RCX, the angle sensor counts once ...[Details]
The data collector of the automatic weather station is generally designed based on a single-chip microcomputer or a PC/104 bus controller. It has the characteristics of good compatibility with PC, low...[Details]
On the afternoon of July 10, Beijing time, Taiwan's largest chip designer MediaTek expects its smartphone chip shipments to grow by double digits in the third quarter of this year, and the company is ...[Details]
In recent years, with the rapid development of the information industry, dot matrix LED display screens have been widely used in various advertising and information display systems such as the fina...[Details]
I've been studying dot matrix recently. It looks simple, but it takes a while to master it completely! The 8*8 dot matrix hardware circuit I'm making now is like this. The row is driven by 74HC138 + t...[Details]
Today, the value of electronic components in cars accounts for 15-20% of the total vehicle. In the future, this proportion may be as high as 30-40% as more safety electronics, fuel consumption and ...[Details]
Corelink Semiconductor has launched the CL1100-based 5-7W E27 LED lighting driver system solution DB2. This driver module meets the requirements of small size (L×W×H=5.1cm×2.1cm×1.8cm), low standby...[Details]
0 Introduction
High-precision current source can provide high-precision current supply for precision instruments, and is suitable for automatic measurement tasks of various resistors in semico...[Details]
The above is to use MB1404 as a stereo composite signal transmitter. You can use the internal high-frequency amplifier and oscillator or not! According to my experience, I still recommend beginners...[Details]
With the continuous advancement of various technologies in the field of measurement and control, the baseband subsystem of general measurement and control equipment has entered the fourth generation o...[Details]
Abstract: Based on the ZigBee parking lot SMS car search system, the location of the vehicle in the parking lot is sent to the owner through SMS, which is convenient for the owner to quickly find ...[Details]