A range of dc rated multi-layer chip capacitors from
0.47pF to 22µF and in case sizes 0603 to 8060 in
C0G/NP0 and X7R dielectrics. Suitable for all general
purpose and high reliability applications where package
size and reliability are important. All are manufactured
using Syfer’s unique wet process and incorporate
precious metal electrodes.
Dissipation Factor
Ageing Rate
Range Dimensions – Standard MLCC Ranges
Length
(L1)
mm/inches
1.6 ± 0.2
0.063 ± 0.008
2.0 ± 0.3
0.08 ± 0.012
3.2 ± 0.3
0.126 ± 0.012
3.2 ± 0.3
0.126 ± 0.012
4.5 ± 0.35
0.18 ± 0.014
4.5 ± 0.35
0.18 ± 0.014
4.5 ± 0.35
0.18 ± 0.014
5.7 ± 0.4
0.225 ± 0.016
5.7 ± 0.4
0.225 ± 0.016
9.2 ± 0.5
0.36 ± 0.02
14.0 ± 0.5
0.55 ± 0.02
20.3 ± 0.5
0.8 ± 0.02
Width
(W)
mm/inches
0.8 ± 0.2
0.031 ± 0.008
1.25 ± 0.2
0.05 ± 0.008
1.6 ± 0.2
0.063 ± 0.008
2.5 ± 0.3
0.1 ± 0.012
2.0 ± 0.3
0.08 ± 0.012
3.2 ± 0.3
0.126 ± 0.012
6.30 ± 0.4
0.25 ± 0.016
5.0 ± 0.4
0.197 ± 0.016
6.3 ± 0.4
0.25 ± 0.016
10.16 ± 0.5
0.4 ± 0.02
12.7 ± 0.5
0.5 ± 0.02
15.24 ± 0.5
0.6 ± 0.02
Max. Thickness
(T)
mm/inches
0.8
0.013
1.3
0.051
1.6
0.063
2.0
0.08
2.0
0.08
2.5
0.1
2.5
0.1
4.2
0.16
4.2
0.16
2.5
0.1
4.2
0.16
2.5
0.1
Termination Band
(L2)
mm/inches
min
0.10
0.004
0.13
0.005
0.25
0.01
0.25
0.01
0.25
0.01
0.25
0.01
0.25
0.01
0.25
0.01
0.25
0.01
0.5
0.02
0.5
0.02
0.5
0.02
max
0.40
0.015
0.75
0.03
0.75
0.03
0.75
0.03
1.0
0.04
1.0
0.04
1.0
0.04
1.0
0.04
1.0
0.04
1.5
0.06
1.5
0.06
1.5
0.06
Size
0603
0805
1206
1210
1808
1812
1825
2220
2225
3640
5550
8060
Custom chip sizes not included in the table, but larger than 2225, can be considered with minimum tooling charges. Please refer specific requests direct to the sales office.
Max thickness relates to standard components and actual thickness may be considerably less. Thicker parts, or components with reduced maximum thickness, can be considered by request – please refer
I recently encountered a problem, and I would like to ask the experts for help. STC12c5a microcontroller, external flash, port p0 is multiplexed as the low 8-bit address line and 8-bit data bit, and p...
Dear friends, we have made a class D amplifier with an output of more than 100W. Now I don’t know why the output waveform is distorted when the output reaches 3A . The inductor we use for the output i...
[i=s] This post was last edited by dontium on 2015-1-23 11:47 [/i] Hi, everyone! This time I share with you the rechargeable battery design of Texas Instruments~~ You are welcome to download it! :vict...
Please recommend a BOOST circuit. (No external power supply) The input voltage range is 17~170V, and the output is 28V. Since this range is too large, I want to perform a two-stage conversion. The fro...
The Spring Festival is a time for family reunion and joy, but now we are worried about this virus crisis. I wish everyone well. As engineers, let's talk about what technologies can help from a technic...
Project Overview
The micro urine analyzer we designed can detect ten parameters of urine, including white blood cells, nitrite, urobilinogen, protein, pH value, occult blood, specific g...[Details]
1 Overview
Drugs are like a "double-edged sword". They can treat diseases but can also cause serious adverse consequences. The dual nature of drugs depends on whether they are used rationally....[Details]
introduction
At the beginning of this century, Veit used Einthoven's galvanometer to record the electrical activity of the human pregnant uterus from the body surface for the first time. In 19...[Details]
Digital-to-analog converters (ADCs) provide the critical conversion of analog signals to digital signals in many systems. They perform amplitude quantization of an analog input signal to a binary fini...[Details]
Sensors have made inroads into automotive, medical, industrial and aerospace applications. But you may not see anything changing yet. Growing demands for safety, convenience, entertainment and efficie...[Details]
Pulse oximeters, non-invasive instruments used to monitor a patient's blood oxygen saturation, are benefiting from moving away from expensive discrete component solutions toward more integrated design...[Details]
1 Overview
The BP01 pressure sensor is specially designed for monitoring blood pressure and is mainly used in portable electronic sphygmomanometers. It uses a precision thick-film ceramic chip and...[Details]
With the rapid development of digital technology, various digital display screens have emerged, including LED, LCD, DLP, etc. There are various control systems for various digital large screens, in...[Details]
In some warehousing management, manufacturing, meteorological observation, scientific research and daily life, the requirements for temperature and humidity are common. For example, the "Interim Pr...[Details]
In the field of software development, the most critical but also the most unpredictable phase is the debugging phase. There are many factors that play a role in the process of software debugging, a...[Details]
To ensure the success of China's TD-SCDMA network commercialization, operators and equipment suppliers need to conduct a large number of tests on networked equipment, among which RF testing is...[Details]
introduction
In engineering practice, ultrasonic waves are often used to measure distances because of their strong directivity, slow energy consumption, and long propagation distance in th...[Details]
Introduction
The home ECG and blood pressure monitoring system consists of a data acquisition and recording device and a host computer electronic medical record management system. Therefor...[Details]
Abstract: This paper introduces the origin and new features of MP4, and introduces the core audio compression technology MPEG-2 AAC (Advanced Audio Coding) based on MP4. Finally, it briefly summari...[Details]
introduction
Every friend who has been in contact with PC since the 286 era must have deeply experienced the convenience brought to our lives and work by the leaps and bounds of comput...[Details]