Rocker Switch, DPDT, Momentary, 10A, 12VDC, Screw Terminal, Rocker Actuator, Panel Mount
Categoryswitch    Become warped plate switch   
File Size192KB,5 Pages
ManufacturerAPEM
Environmental Compliance  
Download Datasheet Parametric View All

KG470A2KXA266XCV01 Overview

Rocker Switch, DPDT, Momentary, 10A, 12VDC, Screw Terminal, Rocker Actuator, Panel Mount

KG470A2KXA266XCV01 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerAPEM
Reach Compliance Codecompliant
ECCN codeEAR99
Is SamacsysN
Actuator typeROCKER
body width20 mm
body height35.5 mm
Body length or diameter43.7 mm
Contact (AC) maximum rated R load10A@250VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@12VDC
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)12 V
Electrical life10000 Cycle(s)
illuminationGREEN LED
JESD-609 codee4
Manufacturer's serial numberKG
Installation featuresPANEL MOUNT
Maximum operating temperature65 °C
Minimum operating temperature-10 °C
method of packingBULK
sealIP65
surface mountNO
Switch actionMOMENTARY
switch functionDPDT
Switch typeROCKER SWITCH
Terminal surfaceSilver (Ag)
Termination typeSCREW
Base Number Matches1
KG series
Power rocker switches
Distinctive features and specifications
K
Protected rocker
K
Illuminated or non-illuminated
K
VDE (EN 61058-1) approved
K
Sealed to IP65
ELECTRICAL SPECIFICATIONS
MATERIALS
• Currrent/voltage rating :
- functions 1 (ON-OFF) and 6 (ON-ON) : 15A 12VDC, 10A 24VDC,
15A 250VAC max., 10mA 14VDC min.
- functions 4 ( ON ON ON) and 4-1R (ON ON MOM) :
8A 12VDC, 5A 24VDC, 8A 250VAC max.
- other functions : 10A 12VDC, 8A 24VDC, 10A 250VAC max.
• VDE approved ratings : 12(4)A 250VAC, T85/55°C
• Initial contact resistance : 10 mΩ max. at 1A 2VDC
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.000 Vrms 50 Hz min. between terminals
• Electrical life : 10.000 cycles min.
• Mechanical life : 2 position models : 100.000 cycles min.
3 position models : 30.000 cycles min.
ENVIRONMENTAL SPECIFICATIONS
• Case : thermoplastic UL94-V0
• Terminals : brass, silver plated
• Contacts : silver grain
• Contact roller : brass, nickel plated
AGENCY APPROVAL
EN 61058-1
Availability
: double pole models,
functions ON-OFF and ON-ON.
Marking
: to order switches
marked VDE, add “VDE” at the
end of model number.
• Degree of protection : IP65
• Shock resistance : 100 g according to IEC 512-4, test 6c
• Vibration resistance : 10-500 Hz - 10 g according to IEC 512-4, test 6d
• Salt spray resistance : 96 hours according to IEC 512-6, test 11f
• Operating temperature : 2 position models : -40°C to + 85°C
3 position models : -10°C to + 65°C
MATRIX MOUNTING
25.00 mini.
(.984 min.)
4.00
(.157)
49.00 mini.
(1.929 min.)
12.20
(.480)
Dimensions
: First dimensions are in mm while
inches are shown as bracketed numbers.
Tolerance
: The general tolerance for
dimensions in this brochure is ± 0,3 (.012).
Overall dimension tolerance is ± 0,5 (.020).
Packaging unit
: 40 pieces
Dimensions, specifications and data shown in this brochure are subject to change without notice.
26
www.apem.com
APEM
Confused about the problem of connecting two different MOS tubes in parallel in the circuit diagram...
[align=left][color=#333333][font=Arial, Microsoft YaHei][size=14px]I am learning an LED shutdown circuit. The circuit uses a MOS switch to shut off the negative pole of the LED. I have a few questions...
flinstone Power technology
6657Statically configure serial port general interrupt in sys/bios
[i=s] This post was last edited by niguangyixia on 2018-12-5 10:41[/i] [font="][size=14px]Help needed:[/size][/font] [font="][size=14px]The serial port interrupts of routine 6657 have been adjusted by...
niguangyixia DSP and ARM Processors
Signals crossing two clock domains
A signal to another clock domainLet's say a signal from clkA domain is needed in clkB domain. It needs to be "synchronized" to clkB domain, so we want to build a "synchronizer" design, which takes a s...
eeleader FPGA/CPLD
ALTERA DDR2 IP customization problem (local_init_done)
I used CYCLONEIII chip, customized DDR2 IP core, and then used SINALTAP to capture signals directly. I found that the reason for the failure to read and write was that local_init_done was always low, ...
zht24kobe FPGA/CPLD
Cyclone V official Chinese data sheet collection
[i=s]This post was last edited by eXiaoqiang2013 on 2015-11-29 22:58[/i] [color=#999999]Cyclone V Series Chinese Datasheet, official Chinese datasheet collection, with bookmarks. Contains three volume...
e小强2013 FPGA/CPLD
"Design and Application Examples of Single Chip Microcomputer Fuzzy Control System"
The knowledge of "Design and Application Examples of Single-Chip Microcomputer Fuzzy Control Systems" will never be out of date. Let's make progress together. Come on!...
cuizhihao MCU

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 685  339  1881  1457  1671  14  7  38  30  34 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号