3365/50 300

Description
CBL RIBN 50COND 0.050 GRAY 300'
CategoryWire/cable   
File Size1MB,5 Pages
Manufacturer3M
Websitehttp://3M.com/esd
Environmental Compliance
Download Datasheet Parametric View All

3365/50 300 Overview

CBL RIBN 50COND 0.050 GRAY 300'

3365/50 300 Parametric

Parameter NameAttribute value
Cable typeflat cable
Number of conductors50
spacing0.050"(1.27mm)
length300.0'(91.44m)
Wire gauge28 AWG
Number of wire strands7 strands/36 AWG
shieldNo shielding
Casing colorgrey
Belt thickness0.035"(0.89mm)
Strip width2.500"(63.50mm)
Sheath (insulation) materialPolyvinyl chloride (PVC)
Voltage300V
Operating temperature-20°C ~ 105°C
gradeUL Type 2651
characteristiczipper
conductor materialCopper, tin plated
Insulation resistance10 G ohms
first conductor markred
3M
Round Conductor Flat Cable
.050" 28 AWG Stranded, PVC
3365 Series
28 AWG wire on .050 inch centers permits mass
termination to a broad line of IDC connectors
Stranded wire provides flexibility and extended
product life
Zippable for branching or discrete termination
Available in Gray or Black
See Regulatory Information Appendix (RIA) for
chemical compliance information
(RIA E1 & C1 apply)
Date Modified: May 7, 2009
TS-0080-B
Sheet 1 of 2
Physical
Insulation:
Material: Polyvinyl Chloride (PVC)
Color: Gray Standard or Black (see ordering information)
Marking:
Standard: None
Canadian Option:
AWM 2651 105C 300V VW1 3M NU C
AWM IA 105C 300V FT1 EU <50V
Conductors:
28 AWG, 7 × 36 [ 7 × Ø 0.127 ] Tinned Stranded Copper (89% Conductivity)
Electrical
Voltage Rating:
USA: 300V
Canada: 300V
Insulation Resistance:
> 1 × 10
10
Ω/10
ft. [ 3 m ]
Characteristic Impedance:
Unbalanced
Balanced
102
Ω
172
Ω
EU: <50V
Capacitance:
Inductance:
Propagation Delay:
Velocity of Propagation:
14.47 pF/ft [ 47.5 pF/m ]
0.15 μH/ft [ 0.49 μH/m ]
1.47 ns/ft [ 4.86 ns/m ]
69%
8.14 pF/ft [ 26.7 pF/m ]
0.24 μH/ft [ 0.79 μH/m ]
1.4 ns/ft [ 4.59 ns/m ]
73%
Note: Unbalanced is measured between ground-signal-ground conductors. Balanced is measured between conductors within a pair.
Environmental
Temperature Rating:
-20°C to +105°C
Canada: FT1
Flammability Rating:
USA: VW-1
UL File No.: E42769, Style No: 2651
3M is a trademark of 3M Company.
For technical, sales or ordering information call
800-225-5373
3
Interconnect Solutions
http://www.3M.com/interconnects/
Show off the keyboard and mouse you received
I received something from EEWORLD, so I should show off the Texas Instruments Bluetooth keyboard. It seems to be version 2.0, and is for iPad. But I don't have such a thing. It can be used by connecti...
wangfuchong Talking
Helper2416-35 - Linux Driver - First Driver (Light Up LED)
[i=s] This post was last edited by yuanlai2010 on 2014-8-26 14:29[/i] [align=center][b][font=华文楷体][size=22.0pt]Linux[/size][/font][/b][b][font=华文楷体][size=22.0pt]Driver - The first driver (lighting up ...
yuanlai2010 Embedded System
The benefits of using TI analog devices in combination with DSP
1) When using TI's DSP, TI's analog devices can be seamlessly connected to the DSP. No connection or switching devices are required between devices. This reduces the size of the board and reduces the ...
fish001 DSP and ARM Processors
To prevent smog, don’t use this weird “Japanese portable air purifier”!
[align=left][font=微软雅黑][size=4]When it comes to haze days, we all know to turn on the air purifier at home and wear a mask when going out. As everyone pays more attention to preventing haze, related a...
eric_wang Talking
How to improve the reliability of microcontrollers from software and hardware?
As the number of programs increases, the programs in the microcontroller become more and more complicated but indispensable. More programs mean more unknown errors. My program may run fine for one or ...
面纱如雾 Microcontroller MCU
【Featured Q&A】Battery protection and fuel gauge design
In battery pack design, battery safety, battery life, battery life, fast charging, etc. are important design considerations. Currently, the battery pack design solutions provided by TI can be applied ...
qwqwqw2088 Energy Infrastructure?

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1266  2631  389  2194  2537  26  53  8  45  52 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号