EEWORLDEEWORLDEEWORLD

Part Number

Search

DT12J31S115DQA8

Description
ROCKER SWITCH, SPST, LATCHED, PANEL MOUNT, ROHS COMPLIANT
Categoryswitch    Become warped plate switch   
File Size303KB,4 Pages
ManufacturerC&K
Environmental Compliance  
Download Datasheet Parametric View All

DT12J31S115DQA8 Overview

ROCKER SWITCH, SPST, LATCHED, PANEL MOUNT, ROHS COMPLIANT

DT12J31S115DQA8 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerC&K
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Is SamacsysN
Actuator typeILLUMINATED ROCKER
body width15 mm
body height14 mm
Body length or diameter21 mm
Contact (AC) maximum rated R load8A@125VAC
Maximum contact current (AC)8 A
Maximum contact voltage (AC)125 V
Electrical life10000 Cycle(s)
JESD-609 codee4
Manufacturer's serial numberDT12
Installation featuresPANEL MOUNT
Maximum operating temperature85 °C
Minimum operating temperature-20 °C
surface mountNO
Switch actionLATCHED
switch functionSPST
Switch typeROCKER SWITCH
Terminal surfaceSilver (Ag)
Termination typeQUICK CONNECT
Base Number Matches1
DT Series
Miniature Double Pole Rocker Switches
NEW!
Features/Benefits
Typical Applications
Illuminated versions available
Small appliances
Double pole switching in
Computers and peripherals
miniature package
Medical instrumentation
Snap-in mounting
RoHS compliant
Models Available
Specifications
CONTACT RATING:
UL/CSA: 8 AMPS @ 125 VAC, 4 AMPS @ 250 VAC
VDE: 10 AMPS @ 125 VAC, 6 AMPS @ 250 VAC.
QH version: 16 AMPS @ 125 VAC, 10 AMPS @ 250 VAC
ELECTRICAL LIFE: 10,000 make and break cycles at full load.
INSULATION RESISTANCE: 10
8
min.
DIELECTRIC STRENGTH: 1,500 VRMS @ sea level.
OPERATING TEMTERATURE: -20ºC to +85ºC
Materials
HOUSING AND ACTUATOR: 6/6 nylon (UL94V-2), black, matte finish.
ILLUMINATED ACTUATOR: Polycarbonate, matte finish.
CENTER CONTACTS: Silver plated, copper alloy.
END CONTACTS: Silver plated AgCdo.
ALL TERMINALS: Silver plated, copper alloy.
NOTE:
For the latest information regarding RoHS compliance, please go
to: www.ittcannon.com/rohs.
NOTE:
Specifications and materials listed above are for switches with standard options.
For information on specific and custom switches, consult Customer Service Center.
Build-A-Switch
To order, simply select desired option from each category and place in the appropriate box. Available options are shown
and described on pages H–67 through H–70. For additional options not shown in catalog, consult Customer Service Center.
Switch Function
DT12
SPST On-None-Off
DT22
DPST On-None-Off
Actuator
J1
Rocker
J2
Two-tone rocker
J3
Illuminated rocker
Actuator Color
2
Black
1
White
3
Red
R
Red, illuminated
A
Amber, illuminated
G
Green, illuminated
Mounting Style/Color
S2
Snap-in, black
S1
Snap-in, white
B2
Recessed snap-in bracket, black
G2
Guard, black
Termination
15
.187” quick connect
02
PC Thru-hole
A
Right angle, PC thru-hole
Rocker
Actuator Marking
(NONE)
No marking
D
ON-OFF
H
”O l” - international ON-OFF
N
Large dot
P
”O -” international ON-OFF
* QF available with termination 15 only.
Contact Rating
QA
Silver (UL/CSA)
QF
Silver (VDE)*
QH
Silver (High current)*
Lamp Rating
(NONE)
No lamp
7
125 VAC neon
8
250 VAC neon
Dimensions are shown: Inch (mm)
Specifications and dimensions subject to change
H
H–67
www.ittcannon.com
When the fruit battery is connected to a load, the voltage and current are halved
Fruit battery, no-load measurement 3V, about 100UA, then connect to MSP430 minimum system or connect a small SMD LED light, and measure the voltage and current at the two ends, just halved!, 1,.7 1.6 ...
莫莫无蚊 Power technology
I don't know what's wrong with the keyboard scanning program. Please help me.
/*Correspondence between keyboard functions and scan values (function in front, scan key number in the back) |--------|--------|--------|---------| |1 (0)|2 (1)|3 (2)|Select (3)| |--------|--------|--...
huangweichi123 51mcu
Discuss a question: Similar to the chicken and egg problem
Our equipment has high-voltage discharge phenomenon, and the main unit equipment is discharged. The current confusing question is whether it is due to IGBT failure that causes overvoltage or overvolta...
eeleader Industrial Control Electronics
Asking for advice: How to delete files that were not closed normally
Symptoms are as follows: The video is stored in the IDE device as an *.avi file. When the video ends abnormally (such as power failure), the generated .avi file can neither be opened nor deleted. I wo...
aaa1 Embedded System
Questions about AD performance analysis
Hello everyone, I use 16-bit AD9268-125, sampling frequency is 62MHz, I use chipscope to store the digital signal after AD conversion, I want to import it into visualanalog for FFT analysis, but I don...
qixiao321 ADI Reference Circuit
Can googleman answer a question? Thanks!
Hello googleman, I saw your post in the forum and would like to ask a question. Here is the situation. Our development platform is Ulong's PXA270 and Linux operating system. Now we want to debug an ex...
yangdi1985 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development