Pressurized Closure System 2-Type 505 is a complete, pressure-
tight, re-enterable closure system for enclosing spliced connections of
communications cable in a wide variety of applications. The 2-Type
closure is offered in seven different diameter sizes (3-inch to 12-inch) and 13
different lengths (18.5" to 82.5"). Custom length closures up to 108 inches
in length are available upon request.
The tools required for installation are a washer cutter tool and a torque
wrench. This system allows for quick and easy re-entry of closures.
Features
•
•
•
•
•
•
•
•
•
•
•
Pressure tight
Re-enterable
Industry common tools used for assembly or re-entry
Constructed of impact- and corrosion-resistant plastic
Craft friendly
Reusable
More than 25-year field history
Used in aerial, underground and manhole applications
Custom lengths available
Suitable for straight and branch splice configurations
C, D and E sizes can handle more than 4200 pairs
3M
™
Pressurized Closure System 2-Type 505
3M
™
Closure System 2-Type
505-Cover
Each complete 2-type cover 505
selection contains:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
Cover halves with installed
sealing gasket
Protective gloves
3M
™
Sealing R-Tape
3M
™
Dry Towlette Wipe DTW
Alignment bars
Alignment bar hardware
Back cover clips
Flanged hex nut
Hex nuts
Pressure valve
3M
™
Cleaning Wipes CSSC20
External ground ribbon
Black cable ties
Bond braid with eyelets
White cable ties
Splice wrap
1
2
16
15
5
14
11
4
13
12
10
9
7
8
3
6
5
3M
™
Pressurized Closure System 2-Type 505
Ordering Code
Covers
2
D
2
A
2-Type Series
Inside Diameter
A
B
C
D
E
5 ¼" (134 mm)
7" (178 mm)
8" (203 mm)
9 ½" (241 mm)
12" (305 mm)
Overall Length of Cover
AA
A
B
C
D*
E*
F*
G*
H*
I*
J*
K*
L*
18 ½" (470 mm)
27 ½" (699 mm)
36" (914 mm)
44 ½" (1,130 mm)
48 ½" (1,232 mm)
52 ¾" (1,340 mm)
57" (1,448 mm)
61 ½" (1,563 mm)
65 ½" (1,664 mm)
69 ¾" (1,772 mm)
74" (1,880 mm)
78 ½" (1,994 mm)
82 ½" (2,096 mm)
Material of Manufacture
2
4
Standard
Fire Retardant
* Custom sizes
3M
™
Closure System 2-Type 505-Endplates
1
Each Complete 2-type endplate
505 selection contains:
1.
Endplate sections
Sheath scuff
3M
™
Sealing Tape RTW
Protective gloves
Cable diameter tape
Sealing washers
Additional longer cable retention clamps
(depending upon endplate ordered)
3M
™
Sealing Tape RTE
3M
™
Scotchlok
™
Shield Bond Connectors
Hose clamps
3M
™
Cleaning Wipes CSSC20
2.
3.
2
3
4.
5.
6.
7.
8.
9.
10.
6
11.
10
11
9
4
5
8
7
Accessories:
•
•
•
•
•
•
•
•
•
3M
™
Washer Cutter Tool WCT11K
3M
™
Spare Blade Kit WCB11K
3M
™
Aerial Hanger Kit AH20K
3M
™
Underground Closure
Support Kit UCS10K
3M
™
Plugging Spools
3M
™
2-Type Tool Kit 2-TYPE/TK
3M
™
4-Hole Spool Kit KWSP04
3M
™
Universal Alignment Tool Kit UAT20K
3M
™
Torque Wrench 2178-2T-LL-CLTK
Tools Required
(not included with cover
or endplate kits)
•
•
•
•
•
•
•
•
•
3M
™
Washer Cutter Tool WCT11K
Speed Wrench
Can wrench with 3/8" (9.5 mm)
and 7/16" (11 mm) ends
1/2" (13 mm) and 7/16" (11 mm)
deep wrench sockets
3" (76 mm) socket extender
Screw driver
Snips
Knife
Tabbing shears
3M
™
Pressurized Closure System 2-Type 505
Ordering Code
Endplates
2
D
2
1E
2-Type Series
Inside Diameter
A
B
C
D
E
5 ¼" (134 mm)
7" (178 mm)
8" (203 mm)
9 ½" (241 mm)
12" (305 mm)
Number of Cable Entries in Endplate
1E
2E
3E
1 Cable
2 Cables
3 Cables
Material of Manufacture
2
4
Standard
Fire Retardant
3M
™
Closure System 2-Type 505-Cover Selection
Determine number of cable pairs, splice bundle diameter and sheath opening required.
Use the proper ordering code, from this table, to indicate your cover selection.
Series Number
Inside Diameter, Inches (mm)
Overall Length
18 ½" (470)
27 ½" (699)
Sheath Opening
10" (254)
19" (483)
2A2
5 ¼" (134)
2B2
7" (178)
2C2
8" (203)
2D2
9½" (241)
2E2
12" (305)
2A2AA
2A2A
H
600
2A2B
H
2A2C
H
2A2D
2A2E
2A2F
2A2G
2A2H
2A2I
2A2J
2A2K
2A2L
2B2AA
2B2A
H
1200
2B2B
H
2B2C
H
2B2D
2B2E
2B2F
2B2G
2B2H
2B2I
2B2J
2B2K
2B2L
2C2AA
2C2A
H
1800
2C2B
H
2C2C
H
2C2D
2C2E
2C2F
2C2G
2C2H
2C2I
2C2J
2C2K
2C2L
2D2AA
2D2A
H
3600
2D2B
H
2D2C
H
2D2D
2D2E
2D2F
2D2G
2D2H
2D2I
2D2J
2D2K
2D2L
2E2AA
2E2A
H
4200
2E2B
H
2E2C
H
2E2D
2E2E
2E2F
2E2G
2E2H
2E2I
2E2J
2E2K
2E2L
Maximum number of cable pairs
(1)
36" (914)
44 ½" (1130)
48 ½" (1232)
52 ¾" (1340)
57" (1448)
61 ½" (1563)
65 ½" (1664)
69 ¾" (1772)
74" (1880)
78 ½" (1994)
82 ½" (2096)
(1)
27 ½" (699)
36" (914)
40" (1016)
44 ¼" (1124)
48 ½" (1232)
53" (1346)
57" (1448)
61 ¼" (1556)
65 ½" (1664)
70" (1778)
74" (1880)
Maximum number of cable pairs based on the following specifications: 2Y2 & 2X2 Series = 24/26 gauge cable using 25 pair modular connectors for straight, in-line,
Alignment bars provided in 505 cover kits. Bold type indicates standard covers.
Endplate Selection
Number of Cable
Openings/Endplate
Ordering Code
1
*1E
2
*2E
3
*3E
9
*9E or S
12
*12E or S
18
*18E or S
27
*27E or S
36
*36E or S
42
*42E(1)
2-Type Endplate
Cable Entrance
Configuration
Series
2A2-(*)
2B2-(*)
A
A
A
A B
B
A
A
B C
B
C
Diameter
In.
(mm)
5Qr"
7"
(134)
(178)
(203)
(241)
(305)
2.2" (56)
3.4" (86)
3.4" (86)
3.4" (86)
N/A
Maximum Cable Outside Diameter
1.6" (41)
2.2" (56)
2.8" (71)
3.4" (86)
4.4" (112)
1.3" (33)
2.2" (56)
2.8" (71
3.4" (86)
4.4" (112)
N/A
2.2" (56)
2.8" (71)
3.4" (86)
N/A
1.0" (25)
1.6" (41)
2.2" (56)
N/A
1.0" (25)
1.6" (41)
2.2" (56)
3.4" (86)
.88" - 1.1"
N/A
N/A
N/A
N/A
N/A
Cable Range Outside Diameter
N/A
N/A
.88" - 1.1"
.88" - 1.1"
N/A
N/A
N/A
N/A
.88" - 1.1"
.88" - 1.1"
N/A
N/A
N/A
N/A
N/A
N/A
.88" - 1.1"
N/A
N/A
N/A
2C2-(*) 8"
2D2-(*) 9Qw"
2E2-(*)
(1)
.88" - 1.1" .88" - 1.1"
.88" - 1.1" .88" - 1.1"
12"
4.0" (102) 3.4" (86)
Tip cable diameters other than cable range shown may be special ordered.
“E” designates solid endplate for new construction. “S” designates split endplate for existing or retrofit applications. 42E not available in split endplate configuration
Note: 2D2 series endplates may be used with 2E2 series covers.
Note: .88” - 1.1” = 22 mm - 28 mm
(2)
3M
™
Closure System 2-Type 505 Ordering Information
To select the correct cover:
1.
Determine number of cable pairs
2. Determine splice bundle diameter
3. Determine sheath opening required
To select the correct endplate:
4. Determine cable entrance configuration
5. Determine outside diameter of each cable
(Outside cable diameter must not exceed pre-sized opening in endplate)
Example:
Number of cable pairs = 1200/24 gauge
Splice bundle diameter = 6" (152 mm)
Sheath opening = 19" (483 mm)
Cable configuration = 3-way
1200 pairs in/600 pairs out x 600 pairs out
Cable outside diameters:
1200 pairs = 2.6" (66 mm)
600 pairs = 1.9" (48 mm)
Correct codes to order one cover and two endplates.
[i=s]This post was last edited by Shenzhen Xiaohua on 2021-11-29 13:32[/i]After the 80251 MCU program is compiled, the following information appearsProgram Size: data=8.0 edata+hdata=1204 xdata=0 cons...
_reg_CSI_CSISR = BIT_SOF_INT; ///BIT_SOF_INT is the value of one bit of the _reg_CSI_CSISR register #define BIT_SOF_INT (0x1 << 16) while(!(_reg_CSI_CSISR & BIT_SOF_INT)); ///Keep detecting the start ...
I want to make something that needs to use Android, support wifi, and have video decoding. However, I don't know where to buy chips, and I haven't decided which one to use. Companies like Samsung, Med...
[i=s]This post was last edited by Xin Xin on 2015-10-14 02:04[/i] [font=微软雅黑][size=3] Let me briefly talk about it first. As the title says, I haven't soldered anything for a long time, because I have...
I saw many foreigners and Chinese people playing with the f4 discovery board online, and many people also said they wanted to make a shield, but I didn't see any results. I used fsmc to connect the LC...
As a wireless broadband metropolitan area network standard, WiMAX technology has greater advantages than previous 3.5GHz MMDS products in terms of non-line-of-sight transmission and spectrum utiliz...[Details]
In this article, the high-performance DSP developed by TI can be used as an effective confidentiality method if it is applied to PC encryption cards.
As an effective network security solution,...[Details]
In recent years, lighting has become an important area that countries around the world are targeting to promote energy conservation and environmental protection. According to statistics, about 20% ...[Details]
introduction
The emergence of high-performance, low-power embedded CPUs and high-reliability network operating systems has made it possible to implement applications with large amounts of comp...[Details]
Contact resistance
is the resistance to current flow through a closed pair of contacts. This type of measurement is performed on devices such as connectors,
relays
, and switches. The...[Details]
1. Background:
The instrument system parameter detection and control of the chemical production workshop of Tangshan Coal Gas Coking Plant are all analog instruments, some of which are eve...[Details]
1. With the development of modern industry and the continuous improvement of automation, some medium and large control systems have been greatly facilitated, which not only makes control easier, bu...[Details]
Product series: PB-B-RS232/485 interface (hereinafter sometimes referred to as "interface") is a product in the PROFIBUS bus bridge series.
The main purpose of the bridge series ...[Details]
1 Introduction
Water resources are the basic conditions for human survival and the lifeline of economic development. The reality shows that due to the global shortage of water resources and th...[Details]
1 Introduction to HART Protocol
HART (Highway Addressable Remote Transducer), an open communication protocol for addressable remote sensor high-speed channels, was launched by Rosemen in the U...[Details]
LED lamps and bulbs are now rapidly replacing incandescent, halogen and CFL (compact fluorescent lamp) light sources in many general lighting applications. Flyback DC/DC converters are the power su...[Details]
The potentiometer is an adjustable electronic component. The main functions of the potentiometer in the circuit are as follows:
1. Used as a voltage divider
A potentiometer is a continuou...[Details]
Among the many members of the single-chip microcomputer family, the MCS-51 series of single-chip microcomputers has occupied the main market of industrial measurement and control and automation eng...[Details]
From the previous section, we have learned that the timer/counter in the microcontroller can have multiple uses, so how can I make them work for the purpose I need? This requires setting the timer/...[Details]
Abstract: The output of high-range acceleration sensor is less than 10 mV under the excitation of small signal. The noise of traditional test system may cover such small voltage signal, so that hig...[Details]