Axial Lead and Cartridge Fuses
Designed to IEC Standard
RoHS
Pb
5 x 20 mm
Time Lag Fuse (SIo-Blo ) Fuse 219XAP Series
®
®
®
• Designed to International (IEC) Standards for use globally.
• Meets the IEC 60127-2, Sheet 6 specification for Time Lag Fuses.
• Available in Cartridge and Axial Lead Format.
• Available in ratings of .040 to 6.3 amperes.
• Enhanced Breaking Capacity, High I
2
t
• RoHS compliant and Lead-Free
• Improved I
2
t
ELECTRICAL CHARACTERISTICS:
% of Ampere
Rating
150%
210%
275%
400%
1000%
Ampere
Rating
.125 – 6.3
.125 – 6.3
.125 – 6.3
.04 – .10
.125 – 6.3
.04 – .10
.125 – 6.3
.04 – .10
power factor
Opening
Time
60 minutes,
Minimum
2 minutes,
Maximum
0.6 sec.,
Min;
10 sec.
Max
0.2 sec.,
Min;
10 sec.
Max
.15 sec.,
Min;
3 sec.
Max
0.04 sec.,
Min;
3 sec.
Max
0.02 sec.,
Min;
0.3 sec.
Max
.01 sec.,
Min;
0.3 sec
Max
ENVIRONMENTAL SPECIFICATIONS:
Operating temperature:
-55˚C to 125˚C
Thermal Shock:
MIL-STD-202F Method 107G, Test Condition B: (5
cycles –65°C to +125°C)
INTERRUPTING RATINGS:
150 amperes @ 250VAC, unity
Vibration:
MIL-STD-202F Method 201A
Humidity:
MIL-STD-202F Method 103B, Test Condition A. high relative
humidity (95%) and elevated temperature (40°C) for 240 hours.
Salt Spray:
MIL-STD-202F Method 101D, Test Condition B
ORDERING INFORMATION:
Catalog
Number
0219.040XAP
0219.050XAP
0219.063XAP
0219.100XAP
0219.125XAP
0219.160XAP
0219.200XAP
0219.250XAP
0219.315XAP
0219.400XAP
0219.500XAP
0219.630XAP
0219.800XAP
0219
001.XAP
0219
1.25XAP
0219
01.6XAP
0219
002.XAP
0219
02.5XAP
0219
3.15XAP
0219
004.XAP
0219
005.XAP
0219
06.3XAP
Ampere
Rating
.040
.050
.063
.100
.125
.160
.200
.250
.315
.400
.500
.630
.800
1
1.25
1.6
2
2.5
3.15
4
5
6.3
Nominal
Voltage
Rating
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
Nominal
Resistance
Cold Ohms
31.862
21.292
14.268
6.018
4.20
2.550
1.60
1.05
0.848
0.535
0.370
0.275
0.164
0.116
0.082
0.055
0.045
0.030
0.023
0.016
0.012
0.011
Nominal
Melting I
2
t
A
2
Sec
0.011
0.017
0.028
0.079
0.130
0.310
0.320
0.540
1.23
1.40
3.00
4.82
9.35
19.2
27.2
44.2
92.7
138.0
202.0
330.0
544.0
1093.0
PHYSICAL SPECIFICATIONS:
Material:
Body: Glass
Cap: Nickel Plated Brass
Leads: Tin Plated Copper
Terminal Strength:
MIL-STD-202F Method 211A,
Test Condition A
Solderability:
Reference IEC 60127 Second Edition 2003-01 Annex A
Product Marking:
Cap 1: current and voltage rating.
Cap 2: Agency approval markings.
Packaging:
Available in Bulk (V=5, H=100, M=1000 pcs/pkg) or on
Tape/Reel (MRET1=1000 pcs/reel).
432
w w w. l i t t e l f u s e . c o m
Axial Lead and Cartridge Fuses
Designed to IEC Standard
RoHS
Pb
5 x 20 mm
Time Lag Fuse (SIo-Blo ) Fuse 219XAP Series
®
®
®
Agency Approvals
Agency Approvals
Certificate No.
Cartridge
NBK220604-E10480A
NBK230604-E10480A
Leaded
NBK220604-E10480B
NBK230604-E10480B
2004010207110266
2003010207079982
Ampere Range
20+0.5
0219
000XAP
1A – 5A
6.3A
1A – 5A
6.3A
125mA – 800mA
1A – 6.3A
Pending —
40mA – 100mA
125mA – 6.3A
5.1+0.6
5.1+0.6
5.2+0.1
-0.2
Certificate No.
0219000XAEP
40
22.5 MAX
5.8 MAX
®
Recognised File No. E10480
Guide No.
JDYX2
®
0.65*
All dimensions in mm
Notes:
* Ratings above 6.3A
have 0.8 mm dia lead
File No.
Acc. Class No.
Licence No.
File No.
Pending
KM41462
604904/604924
402708
310144
40016080
40mA – 100mA
125mA – 800mA
1A – 6.3A
125mA – 5A
D
V
E
Licence No.
Average Time Current Curves
0.125A
0.160A
0.200A
0.250A
0.315A
0.400A
0.500A
0.630A
0.800A
1A
1.25A
1.6A
2A
10000
2.5A
3.15A
4A
5A
6.3A
1
1000
100
TIME IN SECONDS
10
1
0.1
0.01
0.001
0.01
1
10
CURRENT IN AMPERES
100
1000
w w w. l i t t e l f u s e . c o m
433