SFA44T4K209B-F

Description
CAP FILM 4UF 10% 440VAC QC TERM
CategoryPassive components   
File Size234KB,5 Pages
ManufacturerCornell Dubilier
Environmental Compliance
Download Datasheet Parametric View All

SFA44T4K209B-F Overview

CAP FILM 4UF 10% 440VAC QC TERM

SFA44T4K209B-F Parametric

Parameter NameAttribute value
capacitance4µF
Tolerance±10%
Rated voltage - AC440V
Rated voltage - DC-
dielectric materialsPolypropylene (PP), metallized
Operating temperature-40°C ~ 70°C
Installation typeBase installation
Package/casingRadial, Can
size/dimensions2.160" long x 1.310" wide (54.86mm x 33.27mm), lip
TerminationQuick connect, disconnect
applicationMotor running
grade-
characteristic-
Type SF Motor-Run and Power Supply Capacitors
Oil Filled/Impregnated, AC Rated, Metallized Polypropylene Capacitors
Type SF, AC rated metallized polypropylene capacitors provide
starting torque and power factor correction for split phase
motors typically used in refrigeration and air conditioning motor-
run applications. Type SF also may be used to provide noise
suppression, voltage regulation and line current reduction in power
supply applications.
Highlights
Specifications
Click here to view hardware
Capacitance Range
Capacitance Tolerance
Rated Voltage
Operating Temperature Range
Dissipation Factor
Service Life Objective
- Self healing
- Fault current protection up to 10,000 amps AFC
- Low energy consumption
- 4 - tine, 1/4” quick connect lug terminals are standard
- Meets EIA Standard EIA-456-A
- UL recognized File Number E71645
- CSA File Number 223507
5.0 µF to 120.0 µF
±10% standard, ± 6% and ±3% available
240 Vac to 660 Vac
–40 ºC to 70 ºC standard, 90 ºC available
<0.1%
60,000 h with 94% survival rate
RoHS Compliant
Service Life Objective
The service life objective for this series is 60,000 hours of
operating life with a 94% survival rate when operated at
full voltage, 60 Hz, and rated ambient temperature. AC ca-
pacitors are frequently used at voltages and ambient tem-
peratures other than rated conditions. Service life may be
estimated under specific conditions of temperature and
voltage by using the curves as shown below and to the
right.
Capacitance vs. Temperature
The Capacitance vs. Temperature curve may be used to determine
the capacitance change as a function of temperature. Capacitance
varies by no more than ±3% over the operating temperature range.
Capacitance vs. Temperature
Life vs. Temperature
10000
% of Rated Life
1000
100
10
25
50
75
100
125
–20
0
20
40
60
80
Life vs. Voltage
CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 987  330  1591  2554  1118  20  7  33  52  23 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号