EEWORLDEEWORLDEEWORLD

Part Number

Search

ZWS5-5

Description
Proximity Sensor; Sensor Input Type:Inductive; Sensing Range Max:15mm; Sensor Output:SCR, NO/NC; Output Type:SCR
CategoryThe sensor   
File Size2MB,19 Pages
ManufacturerDensei-Lambda (TDK)
Websitehttp://www.densei-lambda.com/indexe.html
Download Datasheet View All

ZWS5-5 Online Shopping

Suppliers Part Number Price MOQ In stock  
ZWS5-5 - - View Buy Now

ZWS5-5 Overview

Proximity Sensor; Sensor Input Type:Inductive; Sensing Range Max:15mm; Sensor Output:SCR, NO/NC; Output Type:SCR

ZWS-AF
-SERIES
Single output 50W ~ 150W
Model name
ZWS150AF
ZWS 100AF-5/
Series Name
Output Power
Option
blank : Molex connector,
PCB type
A : Molex connector,
with-cover type
J : JST connector,
PCB type
JA : JST connector,
with-cover type
ZWS100AF
Active Filter
contained
PC Board Type Power Supply
Output Voltage
Features
ZWS75AF
ZWS50AF
(Low Voltage Directive)
2 year warranty
marking (Low Voltage Directive)
Active Filter contained, PFHC type
Applicable to peak output wattage 120% (12V, 15V, 24V output)
Low leakage current 0.5mA max
Equipped with Remote ON/OFF control
(with-cover type excluded) and output variable voltage
2 year warranty
Specifications
1. Input voltage range
2. Power factor
3. Output Voltage range
4. Cooling
5. Operating ambient
temperature
(Standard mounting)
85~265VAC (47~63Hz) , 120~370VDC universal input
0.99 (typ) 100VAC at full load, 0.95(typ) 200VAC at full load
10%
Convection cooling or Forced air cooling
ZWS50AF,75AF,
Convection cooling -10°C~+50°C:100%,+60°C:70% (with cover:-10°C~+40°C:100%,+50°C:70%)
Forced air cooling -10°C~+60°C:100%,+70°C:70% (with cover:-10°C~+50°C:100%,+60°C:70%)
ZWS100AF
ZWS150AF
6. Withstand voltage
7. Safety standard
8. CE marking
9. EMI
10. Immunity
11. PFHC
12. Functions
Convection cooling -10°C~+50°C:100%,+60°C:60% (with cover:-10°C~+40°C:100%,+50°C:60%)
Forced air cooling -10°C~+60°C:100%,+70°C:70% (with cover:-10°C~+50°C:100%,+60°C:70%)
Convection cooling -10°C~+40°C:100%,+60°C:50% (with cover:-10°C~+30°C:100%,+45°C:50%)
Forced air cooling -10°C~+50°C:100%,+60°C:70% (with cover:-10°C~+40°C:100%,+50°C:70%)
Input-output : 3kVAC (20mA) , Input-FG : 2kVAC (20mA) , Output-FG : 500VAC (100mA) for 1 min
Approved by UL1950
, CSA950(C-UL)
, EN60950(TUV)
and EN50178(TUV)
Conforms to Low Voltage Directive
Meets to EN55011-B,EN55022,FCC-B,VCCI-B
Meets to EN50082-2(EN61000-4-2,-3,-4,-5,-6,-7,-8,-11)
Meets to EN61000-3-2
Over voltage protection,Over current protection,Remote on/off control(for open frame type only)
Product lineup
Model name
ZWS50AF-5
ZWS50AF-12
ZWS50AF-15
ZWS50AF-24
ZWS75AF-5
ZWS75AF-12
ZWS75AF-15
ZWS75AF-24
ZWS100AF-5
ZWS100AF-12
ZWS100AF-15
ZWS100AF-24
ZWS150AF-5
ZWS150AF-12
ZWS150AF-15
ZWS150AF-24
Nominal
output voltage
5V
12V
15V
24V
5V
12V
15V
24V
5V
12V
15V
24V
5V
12V
15V
24V
Max.
output current
10A
4.3A
3.5A
2.1A
15A
6.3A
5.0A
3.2A
20A
8.5A
6.7A
4.3A
30A
12.5A
10A
6.3A
Note 1
Note 1
ZWS50AF
ZWS75AF
ZWS100AF
ZWS150AF
Max. peak
output current
-
5.2A
4.2A
2.6A
-
7.5A
6.0A
3.8A
-
10A
8.0A
5.0A
-
15A
12A
7.5A
Max. average
output power
50.0W
51.6W
52.5W
50.4W
75.0W
75.6W
75.0W
76.8W
100.0W
102.0W
100.5W
103.2W
150.0W
150.0W
150.0W
151.2W
Max. peak
output power
-
62.4W
63.0W
62.4W
-
90.0W
90.0W
91.8W
-
120.0W
120.0W
120.0W
-
180.0W
180.0W
180.0W
UL
CSA
EN
Note1 : Duration at peak current : 10 seconds max. within Max. average output power.
Based on the data under normal installation and without cover type. Needs output derating
according to installation method or ambient temperature condition.
: Safety standard approved
59

Recommended Resources

Can someone please explain to me how the timer is calculated?
For example, the following code: void main(void) { WDTCTL = WDTPW + WDTHOLD; //Stop the watchdog timer P1DIR |= 0x01; //Set P1.0 as output //TA1CTL = RT1SSEL_0 + MC_2 + TAIE; //ACLK, timer A counting ...
wuyanyanke Microcontroller MCU
Model 2602 SourceMeter Instrument Performing LIV Test Sweep
Forward voltage test The forward voltage (VF) test verifies the forward DC characteristics of the laser diode. During the measurement, the current IF is swept and the voltage drop across the laser dio...
Jack_ma Test/Measurement
[Help] Newbie's help
If I make a circuit board according to this simulation diagram, can I just connect the power supply and measure the LED light? If I don't want it to light up immediately after powering on, how can I m...
1774315354 MCU
Touch screen controller
I am going to make a touch screen driver for a controller called TSC2006. What is the difference between it and ADS7846 controller? Can they be used interchangeably? If there is a difference, please d...
jlizheng Embedded System
【MicroPython】Using DS1820 single bus temperature sensor
[i=s]This post was last edited by dcexpert on 2016-4-13 22:41[/i] In the MicroPython source code, there is a single bus driver, which can easily drive single bus devices, such as reading the temperatu...
dcexpert MicroPython Open Source section
Sincerely recruit all kinds of electronic talents
Regular studio, due to the large volume of business, the in-service technology cannot be supplied. Now Chengcheng electrical automation professional part-time technicians, familiar with single-chip mi...
shannon2014 Recruitment

Popular Articles

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 609  586  1157  976  1689  13  12  24  20  35 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号