ZWS150PF-15 Overview

1-OUTPUT 150 W AC-DC PWR FACTOR CORR MODULE

ZWS-AF
-SERIES
Single output 50W ~ 150W
Model name
ZWS150AF
ZWS 100AF-5/
Series Name
Output Power
Option
blank : Molex connector,
PCB type
A : Molex connector,
with-cover type
J : JST connector,
PCB type
JA : JST connector,
with-cover type
ZWS100AF
Active Filter
contained
PC Board Type Power Supply
Output Voltage
Features
ZWS75AF
ZWS50AF
(Low Voltage Directive)
2 year warranty
marking (Low Voltage Directive)
Active Filter contained, PFHC type
Applicable to peak output wattage 120% (12V, 15V, 24V output)
Low leakage current 0.5mA max
Equipped with Remote ON/OFF control
(with-cover type excluded) and output variable voltage
2 year warranty
Specifications
1. Input voltage range
2. Power factor
3. Output Voltage range
4. Cooling
5. Operating ambient
temperature
(Standard mounting)
85~265VAC (47~63Hz) , 120~370VDC universal input
0.99 (typ) 100VAC at full load, 0.95(typ) 200VAC at full load
10%
Convection cooling or Forced air cooling
ZWS50AF,75AF,
Convection cooling -10°C~+50°C:100%,+60°C:70% (with cover:-10°C~+40°C:100%,+50°C:70%)
Forced air cooling -10°C~+60°C:100%,+70°C:70% (with cover:-10°C~+50°C:100%,+60°C:70%)
ZWS100AF
ZWS150AF
6. Withstand voltage
7. Safety standard
8. CE marking
9. EMI
10. Immunity
11. PFHC
12. Functions
Convection cooling -10°C~+50°C:100%,+60°C:60% (with cover:-10°C~+40°C:100%,+50°C:60%)
Forced air cooling -10°C~+60°C:100%,+70°C:70% (with cover:-10°C~+50°C:100%,+60°C:70%)
Convection cooling -10°C~+40°C:100%,+60°C:50% (with cover:-10°C~+30°C:100%,+45°C:50%)
Forced air cooling -10°C~+50°C:100%,+60°C:70% (with cover:-10°C~+40°C:100%,+50°C:70%)
Input-output : 3kVAC (20mA) , Input-FG : 2kVAC (20mA) , Output-FG : 500VAC (100mA) for 1 min
Approved by UL1950
, CSA950(C-UL)
, EN60950(TUV)
and EN50178(TUV)
Conforms to Low Voltage Directive
Meets to EN55011-B,EN55022,FCC-B,VCCI-B
Meets to EN50082-2(EN61000-4-2,-3,-4,-5,-6,-7,-8,-11)
Meets to EN61000-3-2
Over voltage protection,Over current protection,Remote on/off control(for open frame type only)
Product lineup
Model name
ZWS50AF-5
ZWS50AF-12
ZWS50AF-15
ZWS50AF-24
ZWS75AF-5
ZWS75AF-12
ZWS75AF-15
ZWS75AF-24
ZWS100AF-5
ZWS100AF-12
ZWS100AF-15
ZWS100AF-24
ZWS150AF-5
ZWS150AF-12
ZWS150AF-15
ZWS150AF-24
Nominal
output voltage
5V
12V
15V
24V
5V
12V
15V
24V
5V
12V
15V
24V
5V
12V
15V
24V
Max.
output current
10A
4.3A
3.5A
2.1A
15A
6.3A
5.0A
3.2A
20A
8.5A
6.7A
4.3A
30A
12.5A
10A
6.3A
Note 1
Note 1
ZWS50AF
ZWS75AF
ZWS100AF
ZWS150AF
Max. peak
output current
-
5.2A
4.2A
2.6A
-
7.5A
6.0A
3.8A
-
10A
8.0A
5.0A
-
15A
12A
7.5A
Max. average
output power
50.0W
51.6W
52.5W
50.4W
75.0W
75.6W
75.0W
76.8W
100.0W
102.0W
100.5W
103.2W
150.0W
150.0W
150.0W
151.2W
Max. peak
output power
-
62.4W
63.0W
62.4W
-
90.0W
90.0W
91.8W
-
120.0W
120.0W
120.0W
-
180.0W
180.0W
180.0W
UL
CSA
EN
Note1 : Duration at peak current : 10 seconds max. within Max. average output power.
Based on the data under normal installation and without cover type. Needs output derating
according to installation method or ambient temperature condition.
: Safety standard approved
59
Is it true that only “Original” can be displayed alone in the front, what about other categories?
Is it true that only "Original" can be displayed in the front alone, while other categories seem not to be displayed? I just tried it and I don't think it looks good. There are so many blank spaces in...
open82977352 Suggestions & Announcements
Writing a small driver, just getting started, looking for advice
I want to write a driver to count the pulses of the signal source. I plan to detect the rising edge and perform interrupt counting. I wonder if there is any better idea. I hope someone can give me som...
vodomine Embedded System
Why is there a sine wave sandwiched between the modulation waves generated by the DDS chip AD951?
[i] I made a simplex wireless transmitter, using AD9851, DDS frequency synthesis chip. The output modulation wave has a sine wave from nowhere, with a frequency of about 600KHz. The frequency of the w...
读懂狼心 RF/Wirelessly
Dear experts, please give me some pointers.
I have been studying hardware for more than half a year, but I feel like I have no idea what I am doing. From the 51 single-chip microcomputer to the FPGA, I feel like I don't know more and more, and ...
很坦然的突然 FPGA/CPLD
DC/DC Converter Data Sheets – Uncovering the Secrets of System Losses
[align=left][color=#000]Welcome back to the DC/DC converter datasheet series. [url=https://bbs.eeworld.com.cn/thread-491041-1-1.html]Given the introduction to system efficiency in the previous article...
maylove Analogue and Mixed Signal
LDO output voltage
Our company is testing LDO products, but during the test process, the output voltage of some batches is higher than the standard voltage regulation value, resulting in a low yield; I would like to ask...
ljx0938 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 609  1820  64  1482  2782  13  37  2  30  57 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号