PRECISION 2.5 VOLT MICROPOWER
VOLTAGE REFERENCE
ISSUE 2 - FEBRUARY 1998
ZR25D
DEVICE DESCRIPTION
The ZR25D uses a bandgap circuit design to
achieve a precision micropower voltage
reference of 2.5 volts. The device is available
in a small outline SOT23 surface mount
package, ideal for applications where space
saving is important.
The ZR25D design provides a stable voltage
without an external capacitor and is stable
with capacitive loads. The ZR25D is
recommended for operation between 50µA
and 5mA and so is ideally suited to low
power and battery powered applications.
Excellent performance is maintained to an
absolute maximum of 25mA, however the
rugged design and 20 volt processing allows
the reference to withstand transient effects
and currents up to 200mA. Superior
switching capability allows the device to
reach stable operating conditions in only a
few microseconds.
FEATURES
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Small outline SOT23 package.
No stabilising capacitor required
Typical T
C
30ppm/°C
Typical slope resistance 0.4Ω
±
3%, 2% and 1% tolerance
Industrial temperature range
Operating current 50µA to 5mA
Transient response, stable in less than
10µs
Alternative package options available
APPLICATIONS
Battery powered and portable
equipment.
Metering and measurement systems.
Instrumentation.
Test equipment.
Data acquisition systems.
Precision power supplies.
SCHEMATIC DIAGRAM
V
R
G
nd
4-161
ZR25D
ABSOLUTE MAXIMUM RATING
Reverse Current
Forward Current
Operating Temperature
Storage Temperature
25mA
25mA
-40 to 85°C
-55 to 125°C
Power Dissipation (T
amb
=25°C)
SOT23
330mW
ELECTRICAL CHARACTERISTICS
TEST CONDITIONS (Unless otherwise stated) T
amb
=25°C
SYMBOL PARAMETER
CONDITIONS
MIN
V
R
Reverse Breakdown Voltage
I
R
=150µA
LIMITS
TYP MAX
2.525 1
2.55
2
2.575 3
50
5
30
0.4
0.3
90
2
0.8
V
TOL.
%
UNITS
2.475 2.5
2.45
2.5
2.425 2.5
25
0.05
I
MIN
I
R
T
C
†
R
S
§
Z
R
Minimum Operating Current
Recommended Operating
Current
Average Reverse Breakdown
Voltage Temp. Co.
I
R(min)
to
I
R(max)
Slope Resistance
Reverse Dynamic Impedance
I
R
= 1mA
f = 100Hz
I
AC
= 0.1 I
R
I
R
= 150µA
f = 100Hz to
10kHz
µA
mA
ppm/°C
Ω
Ω
E
N
Wideband Noise Voltage
45
µV(rms)
V
R
x
(
T
(
max
)
−
T
(
min
)
)
Reverse Current (µA)
†
T
C
=
(
V
R
(
max
)
−
V
R
(
min
)
)
x
1000000
60
50
40
30
20
10
0
0.2
0.6
1.0
1.4
1.8
2.2
2.6
Note: V
R(max)
- V
R(min)
is the maximum
deviation in reference voltage measured
over the full operating temperature
range.
§
R
S
=
V
R
Change
(
I
R
(
min
)
to I
R
(
max
))
I
R
(
max
) −
I
R
(
min
)
5°C
=8
T
A
5°C
C
=2
T
A
-40°
=
T
A
Reverse Voltage (V)
Reverse Characteristics
4-162