EEWORLDEEWORLDEEWORLD

Part Number

Search

3131-AF1PT-000000-1T2-8A

Description
CIR BRKR THRM 8A 250VAC 32VDC
CategoryCircuit protection   
File Size479KB,6 Pages
ManufacturerE-Switch
Websitehttp://www.e-switch.com
Environmental Compliance
Download Datasheet Parametric View All

3131-AF1PT-000000-1T2-8A Online Shopping

Suppliers Part Number Price MOQ In stock  
3131-AF1PT-000000-1T2-8A - - View Buy Now

3131-AF1PT-000000-1T2-8A Overview

CIR BRKR THRM 8A 250VAC 32VDC

3131-AF1PT-000000-1T2-8A Parametric

Parameter NameAttribute value
Circuit breaker typeThermal type
Rated current8A
Rated voltage - AC250V
Rated voltage - DC32V
Number of poles1
Actuator typeNot included
illuminationblue
Lighting voltage (nominal)10V
Installation typePanel mounting
Thermal Circuit Breaker / Switch Series 3131
Description
Combination of single pole circuit breaker and ON/OFF switch with
soft-touch rocker actuation. Contoured rockers are available with a
choice of colours and legends, with optional illumination. The 3131 is
sealed to provide IP66 rated front of panel water splash protection.
It meets the requirements of circuit breaker standard EN 60934 (IEC
60934): S type, TO.
Typical applications
Motor protection, transformer protection, household appliances and office
equipment, electrical tools, mobile homes, watercraft, construction
vehicles, medical equipment.
Circuit breaker
3131
1
Current ratings and typical internal resistance values
Current
rating (A)
0.1
0.2
0.3
0.4
0.5
0.8
1
1.2
1.5
2
2.5
3
3.5
Internal
resistance (Ω)
94
24
12
5.30
4.20
1.50
0.9
0.80
0.45
0.27
0.0785
0.0595
0.0565
Current
rating (A)
4
5
6
7
8
10
12
14
15
16
18
20
Internal
resistance (Ω)
0.0435
0.0325
0.0215
0.0165
0.0165
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
Technical data
For further details please
Voltage rating
Current rating range
Typical life
see chapter: Technical Information
AC 240 V; DC 28 V
0.1...20 A
0.1...20 A
30,000 operations at 1 x I
N
, inductive
-20...+60 °C (-4...+140 °F)
2.5 kV/2
re-inforced insulation in the operating area
Illumination voltage / power consumption
operating voltage
12 V
24 V
115 V
230 V
power consumption (LED)
Y = yellow
10 mA
10 mA
< 1 mA
< 1 mA
T = blue
10 mA
10 mA
-
-
Ambient temperature
Insulation co-ordination
(IEC 60664)
Dielectric strength
operating area
test voltage AC 3,000 V
current path/current path test voltage AC 1,500 V
Insulation resistance
> 100 MΩ (DC 500 V)
Interrupting capacity I
cn
0.1...2 A
10 x I
N
2.5...20 A
200 A
Interrupting capacity
0.1...16 A:
(UL 1077)
AC 240 V
3,000 A
DC 32 V
2,500 A
Protection class
operating area IP66
(IEC 60529)
terminal area IP00
Vibration
5 g (57-500 Hz) ± 0.38 mm (10-57 Hz)
test to IEC 60068-2-6, test Fc,
10 frequency cycles/axis
25 g (11 ms),
Shock
test to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
Corrosion
test to IEC 60068-2-11,test Ka
Humidity
240 hours at 95 % RH,
test to IEC 60068-2-78, test Cab
approx. 30 g
Mass
Approvals
Authority
VDE
UL
Standard
IEC 60934
UL 1077
C22.2 No 235
UL 1500
Ignition Protected
Rated
voltage
AC 240 V
DC 32 V
AC 250 V
DC 50 V
DC 32 V
Current ratings
0.05 A…20 A
0.05 A…20 A
0.1 A…20 A
2 A…20 A
0.1 A…20 A
1646
www.e-t-a.de
1
Report---Sensor Section
I’m a new member of the sensor section. Please give me your advice!...
laoguo Suggestions & Announcements
The error of ADC10 collecting 1KHz sinusoidal signal is very large
[size=5] I posted my program, which is single-channel. It can measure DC signal, but the error of 800mv 1KHz sine signal is very large, and it only displays 0.1XX (XX is two numbers that change very q...
hpy168888 Microcontroller MCU
Are there any other solutions for syncing data?
We have been using Sqlce to synchronize data with the desktop sql database, but many users do not use sql databases, and the sqlce environment also occupies internal space, so I would like to ask ever...
sdsongge Embedded System
【Transfer】Analysis and treatment of transmission line effects in high-speed circuits
[p=25, null, left][color=rgb(0, 0, 0)][backcolor=rgb(239, 244, 250)][font=宋体, Arial, sans-serif]With the large-scale increase in system design complexity and integration, electronic system designers a...
okhxyyo PCB Design
OfficeSuite software for mobile reading and document editing
With OfficeSuite software, you can carry your Office documents with you anytime and anywhere. In addition, it will be extremely simple to create dynamic text on your phone through this Android softwar...
张毅2018 Integrated technical exchanges
Can you help me figure out why this chip doesn't work?
The main control I use is 51, the crystal oscillator is 12m. I use 51 to control the voice chip. The voice chip works in the three-wire serial port mode, but the voice chip does not respond at all. Af...
zhangkai0215 MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2235  38  1187  1481  1558  46  1  24  30  32 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号