Parameter NameAttribute value
Voltage - Rated5VDC
size/dimensionsSquare - 50mm length x 50mm height
width10.00mm
airflow8.1 CFM(0.227m³/min)
static pressure0.104 inches water column (26.0 Pa)
Bearing typeball
Fan typeTube shaft type
characteristicSpeed ​​sensor (tachometer)
noise28.5 dB
Power (W)800mW
RPM4500 RPM
Termination3 leads
Intrusion protection-
Operating temperature14 ~ 158°F (-10 ~ 70°C)
ApprovalCE,CSA,UL,VDE
weight0.044 lbs (19.96g)
Rated current0.160A
voltage range4.5 ~ 6VDC
Material - Frameplastic
Material - Bladeplastic
Service life at different temperatures60,000 hours at 25°C
2004KL (50
X
10
L
)
EMINEBEA.COM
Auto Restart/Polarity Protection
10M Ω or over with a DC500V Megger
AC 700V 1s
-10°C ~ +70°C (Operating)
-40°C ~ +70°C (Storage)
(non-condensing environment)
25°C
25°C
60,000 Hours (B00)
50,000 Hours (M00)
inch
Units: (mm)
ROTATION
7.87
(200) min
½½½½
½
½
½½½
50
(Pa)
.169
4 – (½4.3
± 0.2
)
½½½
40
B50
Static Pressure
½½½
30
B40
AIR
NAME
PLATE
1.57
(40.0
± 0.2
)
1.98
(50.0
± 0.3
)
½½½
20
Ps
½½½
10
B30
.39
(10.0
± 0.2
)
1.57
(40.0
± 0.2
)
1.98
(50.0
± 0.3
)
0
Rib Type Only
0
0.1
½½½
0.2
½½½
0.3
½½½½
0.4
½½½½
(m
3
/min)
½½½
Air Flow
.169
4 – (½4.3
± 0.2
)
(
½48
)
48
2
(5 .00
1)
00
00
1
1. 5.5)
(2
.169
4 – (½4.3
± 0.2
)
2
(5 .00
1)
Casing : Plastic (Black) 94V-0
Impeller : Plastic (Black) 94V-0
Bearing : Ball Bearing
Lead Wire : UL1061, AWG26, +Red, -Black
1.9
(48.0)
1.57
(40.0)
1.57
(40.0)
1.9
(48.0)
INLET SIDE
1.9
(48.0)
1.57
(40.0)
1.57
(40.0)
1.9
(48.0)
OUTLET SIDE
Rated
Operating
Voltage
Current
Input
Power
Speed
Max.
Air Flow
Max. Static
Pressure
Noise
Mass
MODEL
Product
No.
2004KL-01W-B30-
-
2004KL-01W-B40-
-
2004KL-01W-B50-
-
2004KL-04W-B30-
-
2004KL-04W-B40-
-
2004KL-04W-B50-
-
Rotation: Clockwise
Voltage
(V)
5
5
5
12
12
12
(V)
4.5 ~ 6.0
4.5 ~ 6.0
4.5 ~ 6.0
10.2 ~ 13.8
10.2 ~ 13.8
10.2 ~ 13.8
(A)
*1
0.10
0.16
0.30
0.04
0.07
0.10
(W)
*1
0.50
0.80
1.50
0.48
0.84
1.20
(min
-1
)
*1
3500
4500
5500
3500
4500
5500
CFM
*1
(m
3
/min)
*1
in H
2
O
6.4
8.1
10.2
6.4
8.1
10.2
0.18
0.23
0.29
0.18
0.23
0.29
.06
.10
.14
.06
.10
.14
(Pa)
*1
16.0
26.0
35.0
16.0
26.0
35.0
(dB)
*1
23.0
28.5
34.0
23.0
28.5
34.0
(g)
20
20
20
20
20
20
X00
X00
X00
X00
X00
X00
Airflow Outlet: Air Out Over Struts
*1: Average Values in Free Air
Monkey received it, thanks to cardin6. By the way, let me introduce the electrical assembly method
First of all, I want to thank [url=home.php?mod=space&uid=483447]@cardin6[/url], and also thank eeworld for giving me so many e-coins to spend, haha. In the previous post, cardin6 introduced that the ...
le062 Creative Market
[Preparing for the 2011 National Competition], EEWORLD e-sports exchange group
In order to facilitate better communication among participating netizens, EEWORLD will establish an e-contest exchange group, and everyone is welcome to join! Please join the corresponding group accor...
EEWORLD社区 Electronics Design Contest
MSP430 MCU simulation example: LCD1602 liquid crystal display
1. Brief description of LCD1602 liquid crystal1. Character LCD LCD1602 displays characters: When using 1602 type LCD to display characters, three problems must be solved: generating the ASCII standard...
火辣西米秀 Microcontroller MCU
[Decryption 14] Wireless remote control tank DIY based on 51 single chip microcomputer - wireless remote control handle
[align=center][size=4]>>>>>>>>>>2013-02-06<<<<<<<<<<[/size][/align][size=4] Today I will introduce you to the wireless handle of the remote control tank. In fact, this handle can not only be used on t...
@ZiShi Robotics Development
Newbie seeking guidance Zigbee
We now have a requirement for two movable endpoints A and B to communicate with each other. We want to use Zigbee CC2530 to achieve this. So I would like to ask you a few questions. 1. Can point-to-po...
nonames RF/Wirelessly
What does the hardware circuit of count=count+1; in Verilog look like?
Did you use the add module? How is the 1 at the end done? What difference would it make if count<=count+1; was used? I know one is blocking and the other is non-blocking. What I'm asking about is the ...
ganzhifang Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2138  2784  2766  2500  1429  44  57  56  51  29 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号