EEWORLDEEWORLDEEWORLD

Part Number

Search

HWS150A-48/A

Description
AC/DC CONVERTER 48V 150W
CategoryPower/power management   
File Size482KB,2 Pages
ManufacturerTDK-LAMBDA
Environmental Compliance
Download Datasheet Parametric View All

HWS150A-48/A Overview

AC/DC CONVERTER 48V 150W

HWS150A-48/A Parametric

Parameter NameAttribute value
typeclosed
Number of outputs1
Voltage - input85 ~ 264 VAC
Voltage - Output 148V
Voltage - Output 2-
Voltage - Output 3-
Voltage - Output 4-
Current - Output (maximum)3.3A
Power (W)150W
applicationITE (Business)
Voltage - Isolation3kV
efficiency88%
Operating temperature-10°C ~ 70°C (with derating)
characteristicAdjustable output, DC input capability, telemetry, universal input
Installation typeBase installation
size/dimensions6.30" long x 1.65" wide x 3.23" high (160.0mm x 41.9mm x 82.0mm)
Minimum load required-
ApprovalCE
HWS15A-150A/A Series
50-150W Single Output Industrial Power Supplies
Features
Limited Lifetime Warranty
UL508 approved
SEMI F47 Compliant (high line AC)
Universal Input (85 - 265VAC)
Higher Efficiency Than HWS series
Key Market Segments & Applications
Specifications
Model
Input Voltage Range
Input Current (Typ) (1)
Inrush Current (1)
-
A
A
-
Power Factor (1)
-
Temperature Coefficient
%/°C
Overcurrent Protection
%
Overvoltage Protection
V
Hold Up Time (Typ)
ms
Leakage Current (max)
mA
Remote Sense
-
Indicator
-
Operating Temperature (with cover) °C
Storage Temperature
°C
Humidity (non condensing)
%RH
Cooling
-
Withstand Voltage
VAC
Isolation Resistance
M Ohms
Vibration (non operating)
-
Shock
m/s
2
Safety Agency Approvals
-
Line Dip
-
Conducted & Radiated EMI
-
Immunity
-
Weight (Typ)
g
Size (WxHxD) (with cover)
Inches
mm
MTBF - Telcordia SR-332 issue 3**
Hours
Warranty
-
HWS15A/A
HWS30A/A
HWS50A/A
HWS100A/A
HWS150A/A
85 - 265VAC (47 - 63Hz) or 120 - 370VDC* (Withstands 300VAC for 5s)
0.35 / 0.2
0.65 / 0.4
0.65 / 0.35
1.3 / 0.65
1.9 / 0.95
14 / 28
Meets EN61000-3-2
-
-
0.97/0.91
0.98/0.93
0.98/0.93
<0.02%/°C
>105%
Yes
20
>0.5mA (Typ 0.2mA at 100VAC, 0.4mA at 230VAC)
No
Yes
Green LED = ON
-10°C to +70°C, derate linearly to 20% load from 50°C to 70°C (2)
-30 to +85°C
Operating: 30 - 90%RH, Non operating 10 - 95%RH
Convection
Input to Ground 2kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
>100M at 25°C & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s
2
constant X, Y, Z 1 hour
< 196.1 m/s
2
UL60950-1, CSA60950-1, EN60950-1, EN50178, UL508, CE Mark
Complies with SEMI F47 (200VAC line only)
EN55011 / EN55022-B, FCC-B, VCCI-B
IEC61000-4-2, -3, -4, -5, -6, -8, -11; IEC61000-6-2
190
240
300
470
520
1.24x3.23x3.15 1.24x3.23x3.74 1.24x3.23x4.72
1.3x3.23x6.3
1.65x3.23x6.3
31.5x82x80
31.5x82x95
31.5x82x120
33x82x160
42x82x160
12,116,851
8,169,868
3,726,622
2,963,512
2,676,081
Limited lifetime warranty (See website for terms & conditions)
* Safety certified for AC input only ** 24V output model, 25°C ambiient, full load, 230VAC input
(1) 100/200VAC
(2) HWS15A/A derates linearly to 50% load from 50 to 70°C
1-800-526-2324 • www.us.tdk-lambda.com/lp/
14
Disclaimer: us.tdk-lambda.com/lp/legal.htm
Mobile power USB load detection circuit principle
In the mobile power USB load automatic detection circuit, the B pole of the transistor is connected to the GND pin of the USB interface, and the C pole is connected to the MCU IO pin. When the USB cha...
bink2015 Power technology
Recommended Classic Materials on Software Testing (Thirteen) --- Effective Software Testing
[align=center][size=5][font=宋体]Recommendation of Classic Materials on Software Testing (Thirteen)[/font][font=Times New Roman]---[/font][/size][font=Helvetica, Tahoma, Arial, sans-serif][size=5][color...
tiankai001 Download Centre
I would like to ask an expert, what should I do if the board density is high and the DRV8825 driver motor makes a loud noise?
I have made two new boards. Since they are still in the experimental stage, I am eager to put them into production. So many problems have been exposed, especially the problem of loud motor noise. What...
shenlan0302 TI Technology Forum
Why is there such asymmetry regarding the gain specification?
[size=3][color=#000000][font=Verdana] Some engineers often ask during the design process, "Why are the specified minimum and maximum gain errors of [/font][font=Verdana]ADCs so different?" This articl...
fish001 Analogue and Mixed Signal
ADC front-end design step 1
Modern communication systems and test equipment often need to digitize analog signals as quickly as possible so that signal processing can be completed in the digital domain. However, designing transf...
ZYXWVU Analogue and Mixed Signal
Electronic Engineering World will launch a device search by function classification, please pay attention
In response to the requirements of many electronic engineers, Electronic Engineering World has begun to sort out the functional classification of devices (such as amplifiers, A/D converters, etc.), an...
sw Suggestions & Announcements

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2718  337  1836  2199  2497  55  7  37  45  51 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号