EEWORLDEEWORLDEEWORLD

Part Number

Search

ZWS300BAF12/T

Description
AC/DC CONVERTER 12V 300W
CategoryPower/power management   
File Size504KB,2 Pages
ManufacturerTDK-LAMBDA
Environmental Compliance
Download Datasheet Parametric View All

ZWS300BAF12/T Overview

AC/DC CONVERTER 12V 300W

ZWS300BAF12/T Parametric

Parameter NameAttribute value
typeopen framework
Number of outputs1
Voltage - input85 ~ 265 VAC
Voltage - Output 112V
Voltage - Output 2-
Voltage - Output 3-
Voltage - Output 4-
Current - Output (maximum)25A
Power (W)300W (336W forced air cooling)
applicationITE (Business)
Voltage - Isolation3kV
efficiency89%
Operating temperature-10°C ~ 70°C (with derating)
characteristicAdjustable output, DC input capability, load sharing, PFC, universal input
Installation typeBase installation
size/dimensions7.09" long x 3.31" wide x 1.65" high (180.0mm x 84.0mm x 42.0mm)
Minimum load required-
ApprovalCE,cURus,TUV
ZWS300BAF Series
300W Single Output, Convection Cooled Power Supplies
Features
Universal Input (85 - 265VAC)
Power Factor Corrected
Convection cooling (300W) or Forced Air (336-338W)
Five year warranty
Less than 0.5mA earth leakage current
Key Market Segments & Applications
Specifications
Model
Input Voltage
Input Current
Inrush Current
(1)(2)
Power Factor
Leakage Current
Off Load Power Draw
Temperature Coefficient
Overcurrent Protection
(3)
Overvoltage Protection
Hold Up Time (Typ)
(1)
Efficiency
(1)
Remote On/Off
Operating Temperature
12V & 15V Models
Operating Temperature
24V, 36V & 48V Models
Storage Temperature
Humidity (non condensing)
Cooling
Withstand Voltage
V
A
A
-
mA
W
%/°C
-
V
ms
%
-
°C
°C
ZWS300BAF
85-265VAC (47-63Hz), 120-370VDC
(5)
3.7 / 1.9 (Convection cooled rating)
15 / 30
0.97 at 100VAC, 0.93 at 200VAC, Meets EN61000-3-2
0.5mA Max. Typically 0.2mA (100VAC), 0.4mA (230VAC)
Typically 0.1W at 100VAC, 0.5W at 200VAC, 0.8W at 265VAC when unit is in inhibit
<0.02%/°C
>116% of convection cooled rated output current (>105% for 12V model)
12V: 13.8-16.2V, 15V: 17.3-20.3V, 24V: 28.8-33.6V, 36V: 41.4-48.6V, 48V: 55.2-64.8V
18ms at 100VAC input (Convection cooled rating)
12 & 15V models: 86 / 89%, 24V, 36V & 48V models: 88 / 91% (Convection cooled rating)
Optional, see instruction manual
Convection: -10°C to +70°C, derate linearly to 40% load from 40°C to 70°C
1.4m/s Airflow: -10°C to +70°C, derate linearly to 60% load from 50°C to 70°C
Convection: -10°C to +70°C, derate linearly to 40% load from 45°C to 70°C
0.7m/s Airflow: -10°C to +70°C, derate linearly to 60% load from 50°C to 70°C
1.4m/s Airflow: -10°C to +70°C, derate linearly to 70% load from 60°C to 70°C
-30 to +75°C
Operating: 30 - 90%RH, Storage: 10 - 90%RH
Convection or forced air
Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA), Output to Ground 500VAC
(20mA) for 1 min.
>100M at 25°C & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s
2
constant X, Y, Z 1 hour each
< 196.1 m/s
2
UL60950-1, CSA60950-1, EN60950-1, EN50178 OV II, CE Mark
EN55011/EN55022-B, FCC Class B, VCCI-B
EN61000-4-2 (lvl2, 3), -3 (lvl 3), -4 (lvl 3), -5 (lvl 3, 4), -6 (lvl 3), -8 (lvl 4), -11; EN61000-6-2
540g (open frame)
3.31 x 1.65 x 7.09” (84 x 42 x 180) open frame
Five Years
°C
%RH
-
-
Isolation Resistance
-
Vibration (non operating)
-
Shock
-
Safety Agency Certifications
-
(4)
Conducted & Radiated EMI
-
Immunity
-
Weight (Typ)
g
Size (WxHxD)
in (mm)
Warranty
yrs
Notes:
(1) 100 / 200VAC Input
(2) 25°C ambient (cold start)
(3) Avoid prolonged operartion in overload
(4) Forced air rating: Class A radiated
(5) Safety certified for AC input only
1-800-526-2324 • www.us.tdk-lambda.com/lp/
109
Disclaimer: us.tdk-lambda.com/lp/legal.htm
What is the difference between an audio transformer and a high frequency transformer?
I would like to ask you a question, what is the difference between an audio transformer and a high-frequency transformer?...
xin Power technology
Cypress, ARM and Arrow to jointly host free online embedded and system design conference
[size=4][b][color=darkorchid]You don't need to be there in person[/color], just log in at the designated time to participate. [/b][/size] [size=4][b]Attending [color=darkorchid]PSoC World[/color] will...
EEWORLD社区 Embedded System
Comparison between the new Forester and the Super Vitara
Full-time four-wheel drive: Super Vitara is more authentic Whether it is the toughness of the Super Vitara or the more comfortable and casual handling of the New Forester, they are still an SUV after ...
kleine-katze Automotive Electronics
Low voltage input DC/AC converter module
Low voltage input DC/AC converter module Abstract: This paper introduces the working principle, application scope and technical indicators of low-frequency AC modules working under low voltage input. ...
zbz0529 Analog electronics
How to write a microcontroller program
I use the 89c51 chip. I use a wireless receiving module. The receiving signal pins are like this. There are 3 positive and negative signal output wires. Which io pin should be connected to the microco...
chunxilu1979 Embedded System
Positioning method based on Zigbee underground wireless sensor network
Abstract: According to the requirements of the underground personnel positioning system for positioning methods, a weighted centroid positioning algorithm based on RSSI (Received Signal Strength Indic...
吸铁石上 RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1572  2208  2904  1701  714  32  45  59  35  15 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号