EP2AGX45DF25I3

Description
IC FPGA 252 I/O 572FBGA
CategoryProgrammable logic devices    Programmable logic   
File Size809KB,78 Pages
ManufacturerIntel
Websitehttp://www.intel.com/
Download Datasheet Parametric View All

EP2AGX45DF25I3 Overview

IC FPGA 252 I/O 572FBGA

EP2AGX45DF25I3 Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
MakerIntel
Reach Compliance Codecompliant
JESD-609 codee0
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Programmable logic typeFIELD PROGRAMMABLE GATE ARRAY
Terminal surfaceTIN LEAD
Maximum time at peak reflow temperatureNOT SPECIFIED
1. Device Datasheet for Arria II Devices
December 2013
AIIGX53001-4.4
AIIGX53001-4.4
This chapter describes the electrical and switching characteristics of the Arria
®
II
device family. The Arria II device family includes the Arria II GX and GZ devices.
Electrical characteristics include operating conditions and power consumption.
Switching characteristics include transceiver specifications, core, and periphery
performance. This chapter also describes I/O timing, including programmable I/O
element (IOE) delay and programmable output buffer delay.
f
For information regarding the densities and packages of devices in the Arria II device
family, refer to
Overview for the Arria II Device Family
chapter.
This chapter contains the following sections:
“Electrical Characteristics” on page 1–1
“Transceiver Performance Specifications” on page 1–21
“Glossary” on page 1–74
Electrical Characteristics
The following sections describe the electrical characteristics.
Operating Conditions
Arria II devices are rated according to a set of defined parameters. To maintain the
highest possible performance and reliability of Arria II devices, you must consider the
operating requirements described in this chapter.
Arria II devices are offered in both commercial and industrial grades. Arria II GX
devices are offered in –4 (fastest), –5, and –6 (slowest) commercial speed grades and
–3 and –5 industrial speed grades. Arria II GZ devices are offered in –3 and –4 speed
grades for both commercial and industrial grades.
1
In this chapter, a prefix associated with the operating temperature range is attached to
the speed grades; commercial with the "C" prefix and industrial with the “I” prefix.
Commercial devices are indicated as C4, C5, and C6 speed grade, and the industrial
devices are indicated as I3 and I5.
Absolute Maximum Ratings
Absolute maximum ratings define the maximum operating conditions for Arria II
devices. The values are based on experiments conducted with the device and
theoretical modeling of breakdown and damage mechanisms. The functional
operation of the device is not implied under these conditions.
Table 1–1
lists the
absolute maximum ratings for Arria II GX devices.
Table 1–2
lists the absolute
maximum ratings for Arria II GZ devices.
© 2013 Altera Corporation. All rights reserved. ALTERA, ARRIA, CYCLONE, HARDCOPY, MAX, MEGACORE, NIOS, QUARTUS and STRATIX are Reg. U.S. Pat. & Tm. Off.
and/or trademarks of Altera Corporation in the U.S. and other countries. All other trademarks and service marks are the property of their respective holders as described at
www.altera.com/common/legal.html.
Altera warrants performance of its semiconductor products to current specifications in accordance with Altera’s standard warranty, but
reserves the right to make changes to any products and services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of any
information, product, or service described herein except as expressly agreed to in writing by Altera. Altera customers are advised to obtain the latest version of device
specifications before relying on any published information and before placing orders for products or services.
Arria II Device Handbook Volume 3: Device Datasheet and Addendum
December 2013
Subscribe
What fonts do you use for IAR? How do I add new fonts?
I'm new here, please help. I saw a font called Comic Sans MS on the Internet. It looks good, but it doesn't seem to be included in IAR. Can I add it? It doesn't seem to be as easy as adding it in Word...
大包yy Microcontroller MCU
Keysight-5G data download gift event: heroes compete for supremacy in the martial arts world, 5G knights dominate the world
[size=4][color=blue][b]>>[/b][/color][/size][url=https://mp.weixin.qq.com/s/HDSh-_V69APRAvvsVuNlLA][size=4][color=blue][b]Read the original text to participate in the event[/b][/color][/size][/url] [s...
EEWORLD社区 Test/Measurement
Ask for a sensor
I have a sensor on hand, and after a rough test, I found that the sensor consists of two coils. One coil is used to generate a magnetic field of a certain size, and the other coil is used to detect th...
guguo2010 Industrial Control Electronics
MSP432 LaunchPad uses KEIL5 cannot Load Flash Programming Algorithm
I just got the MSP432P401R LaunchPad a few days ago. I saw that it also supports Keil development, so I was happy to use Keil. I followed the USER Guide process. There is no problem with compilation, ...
wbhb2011 Microcontroller MCU
Wearable network design based on Bluetooth and ZigBee technology
Wearable network refers to a new type of personal area network (PAN) based on short-range wireless communication technology (Bluetooth and ZigBee technology, etc.) and wearable computer (wearcomp) tec...
呱呱 Energy Infrastructure?
What kind of experimental equipment is needed for electronic product development? I hope everyone will speak up! ! !
The company is an electronic equipment company and is going to purchase some equipment recently. The R&D department currently only has a multimeter and an oscilloscope. What other equipment is needed?...
betopelec Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1605  1219  462  2254  1677  33  25  10  46  34 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号