PASSIVE INFRARED WALL SWITCH SEN
CategoryThe sensor   
File Size524KB,4 Pages
ManufacturerThomas Research Products
Environmental Compliance
Download Datasheet Parametric View All

LHIRS1-G-WH Overview

PASSIVE INFRARED WALL SWITCH SEN

LHIRS1-G-WH Parametric

Parameter NameAttribute value
sensor typepassive infrared
Voltage - Power120/277VAC
cover1000 sq. ft.
Output typerelay
Installation typeWall installation
colorWhite
Operating temperature0°C ~ 40°C
Manual modificationyes
LightHAWK
®
2 Wall Switch Occupancy Sensors
INSTALLATION INSTRUCTIONS
DESCRIPTION
The
LightHAWK2
Wall Switch is an intelligent self-adapting occupancy sensor that is designed to replace existing wall switches.
SPECIFICATIONS
• 1000 sq. ft. coverage area (Models: LHIR and LHMT)
• 400 sq. ft. coverage area (Models: LHUS)
• Single or Dual Circuit 120/277VAC, 50/60Hz operation
• Single or Dual Circuit 347VAC, 50/60Hz operation (Canadian version)
• Electrical Ratings: (Each Output Separately)
120VAC – 800W Incandescent, 1000W Ballast, 1/4 HP
277 VAC – 1800W Ballast, 1/4 HP
347VAC – 1500W Ballast
• Adjustable Time Delay: 4-30 minutes, self-adapts based on occupancy
• Light Level Adjustment (Circuit B output on Dual Circuit versions): 10 to 500FC
• UL, cUL Listed
PRECAUTIONS
• CAUTION: RISK OF ELECTRICAL SHOCK.
Turn power off at service panel before beginning installation. Never wire energized
electrical components.
• Read and understand all instructions before beginning installation.
• NOTICE:
For installation by a licensed electrician in accordance with National and/or local Electrical Codes and the following
instructions.
• NOTICE:
For indoor use only.
• CAUTION: USE COPPER CONDUCTOR ONLY
• Confirm device ratings are suitable for application prior to installation. Use of device in applications beyond its specified ratings or
in applications other than its intended use may cause an unsafe condition and will void manufacturer’s warranty.
• NOTICE:
Do not install if product appears to be damaged.
• NOTICE:
Connect to field wiring rated for 60°C or greater.
SAVE THESE INSTRUCTIONS!
INSTALLATION
1.
2.
3.
Turn power OFF at the service panel.
Remove the old switch(es) if applicable.
Wire as shown in the WIRING DIAGRAMS section.
Figures 1 and 2 denote wiring method for Leakage to Ground Sensors.
(NOTE: A secure ground is required for proper operation).
Figures 3 and 4 denote wiring method for Neutral Wiring Sensors.
(NOTE:
If using only a single voltage, connect BOTH the black and violet input wires to the power source.)
Figure 5 shows wiring for Low Voltage models. (NOTE:
Low Voltage models require one UVPP Power Pack per output.)
4.
5.
6.
7.
8.
Install sensor in wall box using mounting screws provided.
Restore power to the sensor and allow it to initialize (up to 2 minutes).
Sensor is factory configured to provide the most energy savings. If additional adjustments are required, see the
ADJUSTMENTS
section.
If daylight harvesting is desired, calibrate the sensor’s photocell as described in the
PHOTOCELL CONTROL
section.
Install a decorator style wall plate (not included).
9601 Dessau Road, Building One
|
Austin, TX 78754 Toll Free: 888-698-3242
|
Fax: 512-450-1215
|
www.hubbell-automation.com
1113B 6.9.2016
Does anyone have a 220v to 5v circuit? I need one. Thank you.
Now I need an av220 to dc5v switching power supply, the load is a thermal printer, I just started learning, I don't know how to design, I hope some great god can give me a circuit, let me learn, thank...
哼哼哈嘿丨墨染 Analogue and Mixed Signal
Can someone tell me if vxworks6.6 supports dual network cards?
I can access the Internet directly or through a shared network, is that ok?...
wenhanbin Real-time operating system RTOS
First release, unboxing post? All the boards I applied for were received~
[i=s]This post was last edited by justd0 on 2021-4-17 00:11[/i]Well, roughly speaking, half a year has passed since I registered for the competition. On such an ordinary working day, a express deliver...
justd0 onsemi and Avnet IoT Innovation Design Competition
[Sample] +LSF0108PWR_UCC28880DR_LP8860AQVFPRQ1_MSP430G2553IN20
[i=s]This post was last edited by yaorumeng on 2014-11-28 14:17[/i] The competition is over. I haven't been to TI for a long time. I caught up with the forum activities and went to TI to apply for a f...
yaorumeng TI Technology Forum
Various short-range wireless communication technologies
[size=4] With the continuous development of communication and information technology, the application pace of short-range wireless communication technology is accelerating and becoming more mature. In...
Jacktang Wireless Connectivity
Why can't I get the SCSI command 12 INQUIRY?
Modified diskperf example on WDK, see if (irpStack->MajorFunction==IRP_MJ_INTERNAL_DEVICE_CONTROL) { //DbgPrint(("liushuanglin tested for cdb ##############################")); CurSrb=irpStack->Parame...
mh2488 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1832  1656  691  1152  1322  37  34  14  24  27 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号