EEWORLDEEWORLDEEWORLD

Part Number

Search

3M 2552 1.5" X 1.25"-100

Description
TAPE DAMP 1 1/2"X 1 1/4" 100/RL
Categoryaccessories   
File Size109KB,4 Pages
Manufacturer3M
Websitehttp://3M.com/esd
Environmental Compliance
Download Datasheet Parametric View All

3M 2552 1.5" X 1.25"-100 Overview

TAPE DAMP 1 1/2"X 1 1/4" 100/RL

3M 2552 1.5" X 1.25"-100 Parametric

Parameter NameAttribute value
Tape typedamping foil
Adhesiveacrylic acid
base fabric, carrierAluminum, extremely soft
thickness0.0150"(15.0 mils,0.381mm)
Thickness - Adhesive0.0050"(5.0 mils,0.127mm)
Thickness - base fabric, carrier0.0100"(10.0 mils,0.254mm)
width1.50"(38.10mm)1 1/2"
length1.25"(31.75mm)1 1/4"
colortransparent
use-
temperature range-25°F ~ 176°F(-32°C ~ 80°C)
shelf life-
Shelf life start date-
Damping Foil
2552
Technical Data
January, 2012
Product Description
3M™ Damping Foil 2552 consists of a room temperature pressure sensitive
viscoelastic polymer on a dead soft aluminum foil and is
designed for application
to vibrating panels and support members.
The combination of viscoelastic
polymer and an aluminum foil backing (a constrained layer damper, or CLD) has
proved to be a unique construction with exceptional ability to control resonant
vibrations in the temperature range of 32° to 140°F (0° to 60°C), with survivability
from -25° to 175°F (-32° to 80°C).
Typical Damping
Properties
The high-energy dissipative polymer used in 3M damping foil 2552 can afford
excellent control of resonance-induced vibrations. When applied to a vibrating
structure, the polymer used in 3M damping foil 2552 converts vibration to negligible
heat. Vibration amplitudes and structure-borne noise can be consequentially reduced.
The performance of most damping devices is highly dependent on the interaction
between the device and the system to which it is applied. A constrained layer control
system is no different than a typical damping device and its ability to provide the
desired performance is affected by parameters other than temperature and frequency.
Namely the geometry, stiffness and the structure to which the control system is applied
will affect the performance.
The loss factor of a material is a dynamic property that can define damping
performance:
The following data are the results of 3M damping foil 2552 being tested per ASTM
E756-83. A sample was applied to a 8.0 inch by 0.5 inch by 0.06 inch steel beam.
The beam was tested over a temperature range of -40° to 140°F, in increments of
10°F. Beam modes 2 through 7 were monitored for system damping measurements.
3M™ Damping Foil 2552
Does the thermal pad on the back of the THS3001 need to be connected to the ground plane?
[i=s] This post was last edited by dontium on 2015-1-23 13:12 [/i] rt, today I was studying the chip manual of THS3001 and found that THS3001 also uses PowerPad technology, but the chip manual does no...
GXT_Python Analogue and Mixed Signal
E There are good books in the gold mine. Read one.
I won’t say much, just look at the picture and you will know....
dongguanze Talking
How to set the coordinate mapping method in EVC
The coordinate mapping method in vc++ can be set directly through SetMapMade(), but EVC drawing cannot. How can I solve this problem? ? ? Thank you...
nwuwmz Embedded System
Principles and requirements for the 2009 National Undergraduate Electronic Design Competition
[i=s]This post was last edited by paulhyde on 2014-9-15 09:30[/i][b][font=华文中宋][size=16pt][font=宋体]I. Principles and requirements of proposition[/font][/size][/font][/b] [font=宋体][font=新宋体-18030][size...
open82977352 Electronics Design Contest
A small problem in the FPGA course design, please help me take a look...
Recently, the teacher assigned a course design to realize a music jukebox using FPGA. Store 3 music scores in ROM, and then switch songs by pressing buttons. The specific requirements are as follows: ...
panxiao FPGA/CPLD
In the ECG common mode rejection ratio test, why is a 20Vrms/50Hz sinusoidal signal selected as the test signal?
As the title says, I have looked at the common mode rejection ratio test schemes of YY1139 and IEC60601-2-25 before. I don’t quite understand why the 20Vrms/50Hz sine test signal is selected. I would ...
dswu233 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 52  624  1181  517  1151  2  13  24  11  55 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号