• Flexibility for application driven lighting design
requirements
• High quality, true color reproduction
• Uniform consistent white light
• Flexibility in design optimization
• Enhanced ease of use and manufacturability
•
Ability to configure multiple Vero SE in series and
parallel reduces customer driver cost
Vero SE
Contents
Product Feature Map
Product Nomenclature
Product Selection Guide
Performance at Commonly Used Drive Currents
Electrical Characteristics
Eye Safety
Absolute Maximum Ratings
Performance Curves
Typical Radiation Pattern
Typical Color Spectrum
Mechanical Dimensions
Packaging and Labeling
Design Resources
Precautions
Disclaimers
About Bridgelux
2
2
3
7
11
12
13
14
20
22
21
25
28
28
28
29
1
Product Feature Map
In addition to delivering the performance and light
quality required for many lighting applications, Décor
Series Class A on Vero SE LED arrays incorporate
several features to simplify the design integration and
manufacturing process, accelerate time to market and
reduce system costs.
Polarity indication marks simplify
manufacturing operator instructions
2D Bar code provides full
manufacturing traceability
Wire release mechanisms x4
Optic mounting holes
T
c
Measurement point
Mounting location
Radial die configuration improves lumen
density and beam control
Zhaga Book 3 compatible
mounting locations
Top side part number marking improves
inventory management and outgoing
quality control
Test port for probing
Dual poke-in connectors
Product Nomenclature
The part number designation for Bridgelux D
é
cor Class A on Vero SE LED arrays is explained as follows:
1 2 3 4
56
7
8 9 10 11
–
12
– 13 14
-
15 16
BXRC – 30 A 1001 – B – 7 3 - SE
Product Family
Nominal CCT
30 = 3,000K
35 = 3,500K
40 = 4,000K
Typical GAI
GAI >80
Special Edition
CCT Bin Options
3 = 3 SDCM
Gen. 7
Array Configuration
Nominal Flux
1001- 1000lm
2001- 2000lm
4001- 4000lm
10K1- 10,000lm
2
Product Selection Guide
The following product configurations are available:
Table 1:
Selection Guide, Pulsed Measurement Data (T
j
= T
c
= 25°C)
Nominal
CCT
1
(K)
3000
3000
3000
3500
3500
3500
4000
4000
4000
3000
3000
3000
3500
3500
3500
4000
4000
4000
3000
3000
3000
3500
3500
3500
4000
4000
4000
3000
3000
3000
3500
3500
3500
4000
4000
4000
Product
Part Number
GAI
2
CRI
3
Nominal
Drive
Current
4
(mA)
270
360
350
270
360
350
270
360
350
450
630
500
450
630
500
450
630
500
900
1170
1050
900
1170
1050
900
1170
1050
1800
1710
2100
1800
1710
2100
1800
1710
2100
Typical Pulsed
Flux
5,6,7
T
c
= 25ºC
(lm)
1056
1407
1026
1137
1516
1106
1210
1614
1176
1836
2570
1869
1974
2763
2009
2111
2955
2150
3696
4807
3594
3974
5167
3864
4251
5527
4134
11209
14197
9444
12050
15263
10153
12890
16327
10861
Minimum
Pulsed Flux
7,8
T
c
= 25ºC
(lm)
929
1238
903
1001
1335
973
1065
1420
1035
1652
2313
1683
1776
2486
1808
1900
2660
1936
3327
4326
3234
3576
4650
3477
3826
4974
3720
10088
12778
8500
10845
13737
9137
11601
14694
9775
Typical
V
f
(V)
35.0
35.0
26.0
35.0
35.0
26.0
35.0
35.0
26.0
35.0
35.0
31.8
35.0
35.0
31.8
35.0
35.0
31.8
35.0
35.0
29.0
35.0
35.0
29.0
35.0
35.0
29.0
52.0
69.4
37.6
52.0
69.4
37.6
52.0
69.4
37.6
Typical
Power
(W)
9.4
12.5
9.1
9.4
12.5
9.1
9.4
12.5
9.1
15.6
21.9
15.9
15.6
21.9
15.9
15.6
21.9
15.9
31.2
40.6
30.4
31.2
40.6
30.4
31.2
40.6
30.4
93.6
118.6
78.9
93.6
118.6
78.9
93.6
118.6
78.9
Typical
Efficacy
(lm/W)
113
113
113
122
122
122
129
129
129
118
118
118
126
126
126
135
135
135
118
118
118
127
127
127
136
136
136
120
120
120
129
129
129
138
138
138
Décor Class A Vero SE 10
Décor Class A Vero SE 10
Décor Class A Vero SE 10
Décor Class A Vero SE 10
Décor Class A Vero SE 10
Décor Class A Vero SE 10
Décor Class A Vero SE 10
Décor Class A Vero SE 10
Décor Class A Vero SE 10
Décor Class A Vero SE 13
Décor Class A Vero SE 13
Décor Class A Vero SE 13
Décor Class A Vero SE 13
Décor Class A Vero SE 13
Décor Class A Vero SE 13
Décor Class A Vero SE 13
Décor Class A Vero SE 13
Décor Class A Vero SE 13
Décor Class A Vero SE 18
Décor Class A Vero SE 18
Décor Class A Vero SE 18
Décor Class A Vero SE 18
Décor Class A Vero SE 18
Décor Class A Vero SE 18
Décor Class A Vero SE 18
Décor Class A Vero SE 18
Décor Class A Vero SE 18
Décor Class A Vero SE 29
Décor Class A Vero SE 29
Décor Class A Vero SE 29
Décor Class A Vero SE 29
Décor Class A Vero SE 29
Décor Class A Vero SE 29
Décor Class A Vero SE 29
Décor Class A Vero SE 29
Décor Class A Vero SE 29
BXRC-30A1001-B-73-SE
BXRC-30A1001-C-73-SE
BXRC-30A1001-D-73-SE
BXRC-35A1001-B-73-SE
BXRC-35A1001-C-73-SE
BXRC-35A1001-D-73-SE
BXRC-40A1001-B-73-SE
BXRC-40A1001-C-73-SE
BXRC-40A1001-D-73-SE
BXRC-30A2001-B-73-SE
BXRC-30A2001-C-73-SE
BXRC-30A2001-D-73-SE
BXRC-35A2001-B-73-SE
BXRC-35A2001-C-73-SE
BXRC-35A2001-D-73-SE
BXRC-40A2001-B-73-SE
BXRC-40A2001-C-73-SE
BXRC-40A2001-D-73-SE
BXRC-30A4001-B-73-SE
BXRC-30A4001-C-73-SE
BXRC-30A4001-D-73-SE
BXRC-35A4001-B-73-SE
BXRC-35A4001-C-73-SE
BXRC-35A4001-D-73-SE
BXRC-40A4001-B-73-SE
BXRC-40A4001-C-73-SE
BXRC-40A4001-D-73-SE
BXRC-30A10K1-B-73-SE
BXRC-30A10K1-C-73-SE
BXRC-30A10K1-D-73-SE
BXRC-35A10K1-B-73-SE
BXRC-35A10K1-C-73-SE
BXRC-35A10K1-D-73-SE
BXRC-40A10K1-B-73-SE
BXRC-40A10K1-C-73-SE
BXRC-40A10K1-D-73-SE
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
93
93
93
93
93
93
93
93
93
93
93
93
93
93
93
93
93
93
93
93
93
93
93
93
93
93
93
93
93
93
93
93
93
93
93
93
Notes for Table 1:
1. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
2. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending
on fixture design and performance.
3. CRI Values are specified as typical.
4. Drive current is referred to as nominal drive current.
5. Products tested under pulsed condition (10ms pulse width) at nominal test current where T
j
(junction temperature) = T
c
(case temperature) = 25°C.
6. Typical performance values are provided as a reference only and are not a guarantee of performance.
7. Bridgelux maintains a ±7% tolerance on flux measurements.
8. Minimum flux values at the nominal test current are guaranteed by 100% test.