EEWORLDEEWORLDEEWORLD

Part Number

Search

ZWS300BAF12/A

Description
AC/DC CONVERTER 12V 300W
CategoryPower/power management   
File Size504KB,2 Pages
ManufacturerTDK-LAMBDA
Environmental Compliance
Download Datasheet Parametric View All

ZWS300BAF12/A Overview

AC/DC CONVERTER 12V 300W

ZWS300BAF12/A Parametric

Parameter NameAttribute value
typeclosed
Number of outputs1
Voltage - input85 ~ 265 VAC
Voltage - Output 112V
Voltage - Output 2-
Voltage - Output 3-
Voltage - Output 4-
Current - Output (maximum)25A
Power (W)300W (336W forced air cooling)
applicationITE (Business)
Voltage - Isolation3kV
efficiency89%
Operating temperature-10°C ~ 70°C (with derating)
characteristicAdjustable output, DC input capability, load sharing, PFC, universal input
Installation typeBase installation
size/dimensions7.09" long x 3.31" wide x 1.65" high (180.0mm x 84.0mm x 42.0mm)
Minimum load required-
ApprovalCE,cURus,TUV
ZWS300BAF Series
300W Single Output, Convection Cooled Power Supplies
Features
Universal Input (85 - 265VAC)
Power Factor Corrected
Convection cooling (300W) or Forced Air (336-338W)
Five year warranty
Less than 0.5mA earth leakage current
Key Market Segments & Applications
Specifications
Model
Input Voltage
Input Current
Inrush Current
(1)(2)
Power Factor
Leakage Current
Off Load Power Draw
Temperature Coefficient
Overcurrent Protection
(3)
Overvoltage Protection
Hold Up Time (Typ)
(1)
Efficiency
(1)
Remote On/Off
Operating Temperature
12V & 15V Models
Operating Temperature
24V, 36V & 48V Models
Storage Temperature
Humidity (non condensing)
Cooling
Withstand Voltage
V
A
A
-
mA
W
%/°C
-
V
ms
%
-
°C
°C
ZWS300BAF
85-265VAC (47-63Hz), 120-370VDC
(5)
3.7 / 1.9 (Convection cooled rating)
15 / 30
0.97 at 100VAC, 0.93 at 200VAC, Meets EN61000-3-2
0.5mA Max. Typically 0.2mA (100VAC), 0.4mA (230VAC)
Typically 0.1W at 100VAC, 0.5W at 200VAC, 0.8W at 265VAC when unit is in inhibit
<0.02%/°C
>116% of convection cooled rated output current (>105% for 12V model)
12V: 13.8-16.2V, 15V: 17.3-20.3V, 24V: 28.8-33.6V, 36V: 41.4-48.6V, 48V: 55.2-64.8V
18ms at 100VAC input (Convection cooled rating)
12 & 15V models: 86 / 89%, 24V, 36V & 48V models: 88 / 91% (Convection cooled rating)
Optional, see instruction manual
Convection: -10°C to +70°C, derate linearly to 40% load from 40°C to 70°C
1.4m/s Airflow: -10°C to +70°C, derate linearly to 60% load from 50°C to 70°C
Convection: -10°C to +70°C, derate linearly to 40% load from 45°C to 70°C
0.7m/s Airflow: -10°C to +70°C, derate linearly to 60% load from 50°C to 70°C
1.4m/s Airflow: -10°C to +70°C, derate linearly to 70% load from 60°C to 70°C
-30 to +75°C
Operating: 30 - 90%RH, Storage: 10 - 90%RH
Convection or forced air
Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA), Output to Ground 500VAC
(20mA) for 1 min.
>100M at 25°C & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s
2
constant X, Y, Z 1 hour each
< 196.1 m/s
2
UL60950-1, CSA60950-1, EN60950-1, EN50178 OV II, CE Mark
EN55011/EN55022-B, FCC Class B, VCCI-B
EN61000-4-2 (lvl2, 3), -3 (lvl 3), -4 (lvl 3), -5 (lvl 3, 4), -6 (lvl 3), -8 (lvl 4), -11; EN61000-6-2
540g (open frame)
3.31 x 1.65 x 7.09” (84 x 42 x 180) open frame
Five Years
°C
%RH
-
-
Isolation Resistance
-
Vibration (non operating)
-
Shock
-
Safety Agency Certifications
-
(4)
Conducted & Radiated EMI
-
Immunity
-
Weight (Typ)
g
Size (WxHxD)
in (mm)
Warranty
yrs
Notes:
(1) 100 / 200VAC Input
(2) 25°C ambient (cold start)
(3) Avoid prolonged operartion in overload
(4) Forced air rating: Class A radiated
(5) Safety certified for AC input only
1-800-526-2324 • www.us.tdk-lambda.com/lp/
109
Disclaimer: us.tdk-lambda.com/lp/legal.htm
How to read and write data through I2C in MSP430FR5739
How can MSP430FR5739 save the data written into FRAM register through I2C? Can any great god give me some advice! ! ! ! ! ! :Cry:...
raitop Microcontroller MCU
[RVB2601 Creative Application Development] Unboxing + Detailed Picture Sharing
First of all, I would like to thank EEWORLD and Pingtou Ge for allowing me to participate in the Pingtou Ge RVB2601 creative application development and giving me such a good learning opportunity. Tha...
lugl4313820 XuanTie RISC-V Activity Zone
MSP430 sampling and timer issues
[i=s] This post was last edited by 905105948 on 2016-11-19 23:22 [/i] The project requires a timer with a 10us interrupt to count time, and then the timer is used to judge the time. The ADC samples on...
905105948 Microcontroller MCU
Register read and write problems
When writing a driver, after mapping the address, there are two methods to operate the register. I wonder if both methods can be used in the driver? 1. Read/write registers through SETREG32 or CLRREG3...
eyeshot Embedded System
How to avoid getting into trouble when designing circuits for bridge sensors
How to Avoid Difficulties When Designing Circuits for Bridge Sensors[align=left][size=14pt]Instrumentation amplifiers condition the electrical signals generated by sensors so that they can be digitize...
dontium ADI Reference Circuit
Participate and win gifts, 2014 TI MSP430 Technology Seminar is now open for registration!
[font=微软雅黑][size=2]Registration for the 2014 TI MSP430 Technology Seminar is now open! This event covers 8 major cities across the country, and strongly recommends the MSP430's most popular ultra-low ...
EEWORLD社区 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 973  1460  2095  1628  1515  20  30  43  33  31 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号