Part Number:
5284UE
PTZ, #23-2pr, #16-2c, CMR
Product Description
PTZ (Control + Power) Cable, Riser-CMR, 2-23 AWG solid bare copper pairs with polyolefin insulation, 2-16 AWG stranded bare copper conductors with
polyolefin insulation, PVC jacket
Technical Specifications
Product Overview
Suitable Applications:
UTP-CCTV, CCTV Video/Control, Surveillance, Video Over Twisted Pairs, Closed Circuit Television
Physical Characteristics (Overall)
Conductor
Element AWG Stranding
Data
Power
23
16
Solid
19x29
Material
BC - Bare Copper
Nominal Diameter No. of Conductors No. of Pairs
0.023 in
2
2
TC - Tinned Copper 0.059 in
2
2
23 AWG
Conductor Count:
Total Number of Pairs:
Conductor Size:
Insulation
Material
PO - Polyolefin
Nominal Diameter
0.04 in
PP - Polypropylene 0.077 in
Color Chart
Number
Pair 1
Pair 2
Color
Blue and White/Blue
Orange and White/Orange
Conductor 1 Red
Conductor2
Black
Inner Shield Material
Material
Unshielded
Outer Shield Material
Material
Unshielded
Outer Jacket Material
Material
Nominal Diameter Nominal Wall Thickness
0.019 in
F-R PVC - Flame Retardant Polyvinyl Chloride 0.233 in
Electrical Characteristics
Conductor DCR
Element Max. Conductor DCR Max. DCR Unbalance Nominal Conductor DCR
Data
Power
90 Ohm/km
14.7 Ohm/km
5%
90 Ohm/km
14.7 Ohm/km
Capacitance
Max. Capacitance Unbalance Nom. Capacitance Conductor to Conductor
330 pF/ft
15 pF/ft
High Frequency (Nominal/Typical)
Frequency [MHz]
1 MHz
4 MHz
8 MHz
10 MHz
16 MHz
20 MHz
25 MHz
31.25 MHz
62.5 MHz
100 MHz
Delay
Max. Delay Max. Delay Skew Nominal Delay Nominal Velocity of Propagation (VP) [%]
45 ns/ft
High Freq
Frequency
[MHz]
1 MHz
4 MHz
8 MHz
10 MHz
16 MHz
20 MHz
25 MHz
31.25 MHz
62.5 MHz
100 MHz
Voltage
UL Voltage Rating
300 V RMS
Mated Connection
Min. Return Loss Belden** (dB)
25 dB
25 dB
25 dB
25 dB
25 dB
25 dB
25 dB
Electrical Characteristics Notes:
Other Electrical Characteristic 2:
Max. Capacitance Unbalance for Pair: 330 pf/ft
Maximum DCR Unbalance for Pair @ 20°C: 5%
Max. Insertion Loss (Attenuation) Min. PSNEXT [dB] Min. PSACR [dB] Min. PSACRF (PSELFEXT) [dB] Min. RL (Return Loss) [dB] Max./Min. Fitted Impedance
2 dB/100m
4.1 dB/100m
5.8 dB/100m
6.5 dB/100m
8.2 dB/100m
9.3 dB/100m
10.4 dB/100m
11.7 dB/100m
17 dB/100m
22 dB/100m
62 dB
53 dB
48 dB
47 dB
44 dB
42 dB
41 dB
39 dB
35 dB
32 dB
60 dB
49 dB
43 dB
41 dB
36 dB
34 dB
31 dB
28 dB
19 dB
11 dB
61 dB
49 dB
43 dB
41 dB
37 dB
35 dB
33 dB
31 dB
24 dB
21 dB
20 dB
23 dB
24.5 dB
25 dB
25 dB
25 dB
24.3 dB
23.6 dB
21.5 dB
20.1 dB
100 ± 15%
100 ± 15%
100 ± 15%
100 ± 15%
100 ± 15%
100 ± 15%
100 ± 15%
100 ± 15%
100 ± 15%
100 ± 15%
70 ns/100m
45 ns/ft
70 %
Temperature Range
Operating Temp Range:
-20°C To +75°C
Mechanical Characteristics
Bulk Cable Weight:
Max Recommended Pulling Tension:
Min Bend Radius/Minor Axis:
32 lbs/1000ft
105 lbs
2 in
Standards
NEC Articles:
NEC/(UL) Specification:
800
CMR
CEC/C(UL) Specification:
ISO/IEC Compliance:
Other Standards:
CMG
ISO/IEC 11801, Category 5e for data pair
ISO/IEC 11801, Category 5e
Applicable Environmental and Other Programs
EU Directive 2000/53/EC (ELV):
EU Directive 2003/11/EC (BFR):
EU Directive 2011/65/EU (ROHS II):
EU Directive 2012/19/EU (WEEE):
EU Directive 2015/863/EU:
EU Directive Compliance:
EU CE Mark:
EU RoHS Compliance Date (yyyy-mm-dd):
CA Prop 65 (CJ for Wire & Cable):
MII Order #39 (China RoHS):
Yes
Yes
Yes
Yes
Yes
Yes
Yes
2005-04-01
Yes
Yes
Suitability
Suitability - Indoor:
Yes
Flammability, LS0H, Toxicity Testing
C(UL) Flammability:
UL Flammability:
UL voltage rating:
FT4
UL1666 Riser
300 V RMS
Plenum/Non-Plenum
Plenum (Y/N):
Plenum Number:
No
6284UE
Part Number
Variants
Item #
Color Footnote
C
5284UE 0101000 Black
5284UE 0091000 White C
5284UE 009500
Footnote:
White C
C - CRATE REEL PUT-UP.
© 2018 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without
notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages
(including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief
at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product
Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and
regulations based on their individual usage of the product.