A range of dc rated multi-layer chip capacitors from
0.47pF to 22µF and in case sizes 0603 to 8060 in
C0G/NP0 and X7R dielectrics. Suitable for all general
purpose and high reliability applications where package
size and reliability are important. All are manufactured
using Syfer’s unique wet process and incorporate
precious metal electrodes.
Dissipation Factor
Ageing Rate
Range Dimensions – Standard MLCC Ranges
Length
(L1)
mm/inches
1.6 ± 0.2
0.063 ± 0.008
2.0 ± 0.3
0.08 ± 0.012
3.2 ± 0.3
0.126 ± 0.012
3.2 ± 0.3
0.126 ± 0.012
4.5 ± 0.35
0.18 ± 0.014
4.5 ± 0.35
0.18 ± 0.014
4.5 ± 0.35
0.18 ± 0.014
5.7 ± 0.4
0.225 ± 0.016
5.7 ± 0.4
0.225 ± 0.016
9.2 ± 0.5
0.36 ± 0.02
14.0 ± 0.5
0.55 ± 0.02
20.3 ± 0.5
0.8 ± 0.02
Width
(W)
mm/inches
0.8 ± 0.2
0.031 ± 0.008
1.25 ± 0.2
0.05 ± 0.008
1.6 ± 0.2
0.063 ± 0.008
2.5 ± 0.3
0.1 ± 0.012
2.0 ± 0.3
0.08 ± 0.012
3.2 ± 0.3
0.126 ± 0.012
6.30 ± 0.4
0.25 ± 0.016
5.0 ± 0.4
0.197 ± 0.016
6.3 ± 0.4
0.25 ± 0.016
10.16 ± 0.5
0.4 ± 0.02
12.7 ± 0.5
0.5 ± 0.02
15.24 ± 0.5
0.6 ± 0.02
Max. Thickness
(T)
mm/inches
0.8
0.013
1.3
0.051
1.6
0.063
2.0
0.08
2.0
0.08
2.5
0.1
2.5
0.1
4.2
0.16
4.2
0.16
2.5
0.1
4.2
0.16
2.5
0.1
Termination Band
(L2)
mm/inches
min
0.10
0.004
0.13
0.005
0.25
0.01
0.25
0.01
0.25
0.01
0.25
0.01
0.25
0.01
0.25
0.01
0.25
0.01
0.5
0.02
0.5
0.02
0.5
0.02
max
0.40
0.015
0.75
0.03
0.75
0.03
0.75
0.03
1.0
0.04
1.0
0.04
1.0
0.04
1.0
0.04
1.0
0.04
1.5
0.06
1.5
0.06
1.5
0.06
Size
0603
0805
1206
1210
1808
1812
1825
2220
2225
3640
5550
8060
Custom chip sizes not included in the table, but larger than 2225, can be considered with minimum tooling charges. Please refer specific requests direct to the sales office.
Max thickness relates to standard components and actual thickness may be considerably less. Thicker parts, or components with reduced maximum thickness, can be considered by request – please refer
[i=s]This post was last edited by airqj on 2014-4-13 21:35[/i] I want to use BBB to do FFT. I originally planned to write it myself, but I found a good thing called fftw. . . :pleased: fftw can automa...
A few days ago, I saw netizens using STM32 to run WIFI. I thought it was very interesting, so I wanted to start one myself.Since I just started and only send commands to scan wireless nodes, I want to...
How do you determine the functionality of a new FPGA? Here is a Xilinx test engineer explaining the 7 series FPGA: [flash]http://player.youku.com/player.php/sid/XMTg3NDU0OTky/v.swf[/flash]...
It's like this, I want to change the value of the digital tube and the host computer (serial communication) by changing the PCF8591 peripheral potentiometer. I use I2C bus communication, and the assig...
There are two interrupt vector source files for 28335 provided by TI, DSP2833x_DefaultIsr.c and DSP2833x_SWPrioritizedDefaultIsr.c. When I included these two files into the project, the prompt symbol ...
Calibrators are widely used in university experiments. Among them, there are two experiments in nuclear physics experiments in modern physics experiments (GM counter and β absorption) that require ...[Details]
Although improper medical device product design is not always associated with medical device-related errors. Studies of users have shown that lack of adequate training accounts for 70% to 90% of suc...[Details]
Project Overview
The micro urine analyzer we designed can detect ten parameters of urine, including white blood cells, nitrite, urobilinogen, protein, pH value, occult blood, specific g...[Details]
As medical equipment develops towards intelligence, miniaturization, serialization, digitization, and multi-functions, the logic control devices in medical equipment have also evolved from medium- a...[Details]
Magnetic resonance imaging (MRI) systems can take high-resolution cross-sectional perspective images of the human body, providing very useful information for medical diagnosis. The radio frequency pro...[Details]
introduction
At the beginning of this century, Veit used Einthoven's galvanometer to record the electrical activity of the human pregnant uterus from the body surface for the first time. In 19...[Details]
Digital-to-analog converters (ADCs) provide the critical conversion of analog signals to digital signals in many systems. They perform amplitude quantization of an analog input signal to a binary fini...[Details]
For more than 10 years, analog-to-digital converters (ADCs) have been widely used in industrial process control, medical instruments, communication systems, radar and other products as a booster of in...[Details]
With the rapid development of digital technology, various digital display screens have emerged, including LED, LCD, DLP, etc. There are various control systems for various digital large screens, in...[Details]
JTAG Technology Introduction
One disadvantage of shrinking technology is that the complexity of testing small devices increases dramatically. When the board area is large, the board is tested...[Details]
To ensure the success of China's TD-SCDMA network commercialization, operators and equipment suppliers need to conduct a large number of tests on networked equipment, among which RF testing is...[Details]
Many MEMS devices, such as accelerometers and mechanical resonance devices, require a vacuum environment to realize their designed functions. However, verifying whether the package cavity has reach...[Details]
introduction
Cars are becoming an indispensable part of people's lives. However, what worries car users is that the theft of cars is increasing year by year. This paper aims to design a conven...[Details]
introduction
With the rapid development of my country's aviation industry, various new aircraft and control equipment have been successfully developed. Some previous measurement and control eq...[Details]
Lithium-ion batteries have a high energy-to-weight and energy-to-volume ratio, no memory effect, can be recharged many times, have a long service life, and are becoming increasingly cheaper. A good...[Details]