CIRC BRKR THRM

Thermal Circuit Breaker 3120-F...
Description
The 3120 circuit breaker/switch combination is an ON/OFF switch
with integral overcurrent protection (S-type TO CBE to EN/IEC
60934). The trip element is a bimetal. Type 3120 is ideally suited for
overload protection of motors, pumps, transformers and cables.
The 3120 circuit breaker is also available as a switch-only version in
accordance with the IEC/EN 61058 (see data sheet switch 3120-F-..Q1).
Product characteristics:
l
rocker or push button actuation
l
single pole and double pole versions
l
reliable switching behaviour (positively trip-free)
l
convenient snap-in mounting
l
international approvals
Options and add-on modules:
illumination
l
water splash protection
l
auxiliary contacts
l
under voltage trip
l
remote trip
l
magnetic trip
l
push-in terminals
l
appliance inlet module
l
1
Technical data
For details please see Technical information
Rated voltage
Current rating range
AC 240 V, DC 50 V
0.1...20 A
(up to 30A upon request for single pole
units)
30,000
30,000
30,000
30,000
operations
operations
operations
operations
at
at
at
at
at
at
at
at
1
1
1
1
1
1
1
1
x
x
x
x
x
x
x
x
I
N
,
I
N
,
I
N
,
I
N
,
I
N
,
I
N
,
I
N
,
I
N
,
inductive
inductive
resistive
inductive
inductive
inductive
inductive
inductive
Typical applications
Medical and laboratory equipment, apparatus and machine
construction, professional tools, household and garden appliances,
offices machines, audio equipment, machine tools
Typical life 1-pole
0.1...20 A
0.1...4 A
4.5...16 A
DC 28 V:
0.1...20 A
Typical life 2-pole
AC 240 V:
AC 240 V:
DC 50 V:
Current ratings and internal resistance values
Current rating
(A)
0.1
0.2
0.3
0.4
0.5
0.6
0.8
1
1.2
1.5
2
2.5
3
3.5
Internal
resistance
per pole (Ω)
94
24
12
5.30
4.20
2.90
1.50
0.9
0.80
0.45
0.27
0.0785
0.0595
0.0565
Current rating
(A)
4
4.5
5
6
7
8
10
12
14
15
16
18
20
Internal
resistance
per pole (Ω)
0.0435
0.0435
0.0325
0.0215
0.0165
0.0165
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
0.1...16 A 50,000 operations
17...20 A 30,000 operations
DC 50 V:
0.1...16 A 50,000 operations
17...20 A 50,000 operations
Ambient temperature
-30 … 60 °C
Insulation coordination
(IEC 60664)
Dielectric strength
Operating area
pole to pole (2-pole)
Insulation resistance
Interrupting capacity I
cn
2.5 kV /2 reinforced insulation at
operating area
test voltage AC 3,000 V
test voltage AC 1,500 V
> 100 MΩ (DC 500 V)
0.1...2 A
10 x I
N
2.5...20 A
1-pole 150 A
2-pole 250 A
Interrupting capacity (UL 1077)
I
N
1-pole, 2- pole
1-pole, 2- pole
0.1...20 A
0.1...20 A
U
N
AC 250 V
DC 50 V
I
nc
5000 A, C, 1
1000 A, C, 1
Degree of protection
(IEC 60529)
Vibration
Current consumption of illumination
Operating voltage
DC 12 V
DC 24 V
DC 48 V
AC 115 V
AC 230 V
Current consumption
Y
5.2 mA
4.5 mA
4.5 mA
2.8 mA
2.2 mA
R
2 mA
2.2 mA
2 mA
1.1 mA
0.9 mA
G
1.4 mA
1.6 mA
1.6 mA
1 mA
0.9 mA
Shock
Corrosion
Humidity
Mass
operating area IP40
terminal area IP00
with water splash cover IP54 or IP66
8 g (57-500 Hz), ± 0.61 mm (10-57 Hz)
test to IEC 60068-2-6, test Fc
10 frequency cycles/axis
30 g (11 ms)
test to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
test to IEC 60068-2-11, test Ka
240 hrs in 95 % RH
test to IEC 60068-2-78,
test Cab
approx. 33 g (2-pole)
approx. 27 g (1-pole)
approx. 42 g (2-pole with PT terminals)
1806
www.e-t-a.de
1
Apply for sample power meter project
Project: Power Meter Background: The company already has instruments with MSP430 as the controller. On this basis, the main control chip is replaced with LPC1100 series controller to improve performan...
caine1012 NXP MCU
Ask everyone for advice on effective version management
[i=s]This post was last edited by elvike on 2017-1-13 00:43[/i] I have never had the concept of version management. I would save files every day after making certain progress. As a result, more and mo...
elvike Integrated technical exchanges
stm32 usart and timer interrupt nesting problem
In the motor control, TIM1 is used for 50us timing, USART1 interrupt is used to communicate with PC, the USART1 interrupt program receives data from PC and the timing interrupt generates PWM correctly...
bluesky1234 stm32/stm8
Some information about power supply
This is some information about power supplies that I found. Please see if it is useful....
open82977352 MCU
I have an msp430f5529launchpad board but don't know how to learn it
Most of the tutorials on msp430 found on the Internet are for 149. Is it possible to learn 5529 by watching 149 videos?...
z704807308 Microcontroller MCU
Could you please advise me on adding a chip or circuit between the power supply and the high-power electromagnetic coil?
[color=#333333][color=#333333][backcolor=transparent][font=微软雅黑][size=18px]I would like to ask you all, I bought a 24V/15A switch[/size][/font][/backcolor][/color][/color][color=#333333][color=#333333...
乐君羊 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2919  1422  1184  948  107  59  29  24  20  3 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号