8340-T120-K1T1-ALH0-50A

Description
CIR BRK MAG-HYD 50A 240VAC/80VDC
CategoryCircuit protection   
File Size402KB,6 Pages
ManufacturerE-Switch
Websitehttp://www.e-switch.com
Download Datasheet Parametric View All

8340-T120-K1T1-ALH0-50A Online Shopping

Suppliers Part Number Price MOQ In stock  
8340-T120-K1T1-ALH0-50A - - View Buy Now

8340-T120-K1T1-ALH0-50A Overview

CIR BRK MAG-HYD 50A 240VAC/80VDC

8340-T120-K1T1-ALH0-50A Parametric

Parameter NameAttribute value
Circuit breaker typeMagnetic (hydraulic delay)
Rated current50A
Rated voltage - AC240V
Rated voltage - DC80V
Number of poles2
Actuator typepress slice
illuminationnone
Lighting voltage (nominal)-
Installation typeDIN rail
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...
Description
Single, two and three pole magnetic and hydraulic-magnetic circuit
breakers with trip-free mechanism and toggle actuation. A choice of
fast magnetic only or hydraulically delayed switching characteristics
(S-type MO or HM CBE to EN 60934) ensures suitability for a wide
range of applications. Featuring a combi-foot design for symmetric rail
mounting. Low temperature sensitivity at rated load.
Approved to CBE standard EN 60934 (IEC 60934).
Typical applications
Power supplies, control equipment, communication systems, EDP
systems.
Standard current ratings and typical internal resistance values
Current
rating (A)
0,02
0,05
0,1
0,25
0,5
0,75
1
2
2,5
3
5
6
8
10
12
15
16
20
25
30
40
50
Internal resistance values (Ω) per pole
F1
1 493
276
58
8,2
2,3
0,98
0,58
0,145
0,096
0,065
0,025
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,01
< 0,01
953
152
37
6,0
1,47
0,63
0,35
0,096
0,061
0,048
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
-
-
F2
K1, M1, T1
2 669
452
100
15,5
3,9
1,65
0,95
0,26
0,15
0,10
0,042
0,029
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,01
< 0,01
K2, M2, T2
2 457
376
94
14,7
3,2
1,56
0,90
0,20
0,15
0,10
0,040
0,028
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
-
-
single pole
8340-T...
1
three pole
Technical data
For further details please see chapter: Technical Information
Voltage rating
3 AC 415V; AC 240V (50/60Hz); DC 80V
(higher DC voltages to special order)
Current rating range
0.02...50 A DC
0.02...30 A AC
Auxiliary circuit
1 A, AC 240 V/DC 65 V; 0.5 A DC 80 V
Typical life
3 AC 415 V AC 240 V:
0.02...30 A 6,000 operations at 1 x I
N
, inductive
10,000 operations at 1 x I
N
, resistive
WDC 80 V: 0.02...25 A 6,000 operations at 1 x I
N
, inductive
0.02...30 A 10,000 operations at 1 x I
N
, resistive
40 + 50 A 6,000 operations at 1 x I
N
, resistive
Ambient temperature
-40...+85 °C (-40...+185 °F)
Insulation co-ordination
rated impulse
pollution
(IEC 60664 and 60664A)
withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A)
operating area
test voltage AC 3,000 V
Line to Load
test voltage AC 1,500 V
pole to pole
(2- and 3-pole)
test voltage AC 1,500 V
main to auxiliary circuit test voltage AC 1,500 V
Insulation resistance
> 100 MΩ (DC 500 V)
Interrupting capacity
6 x IN at AC;
IEC 60934 - test sequence E 4 x IN at DC
Interrupting capacity
I
N
0.02...20 A
25...30 A
(UL 1077)
AC:
1-pole AC 250 V/3,500A AC 250 V/3,500A
2-pole
3-pole
DC:
1-pole
2-pole
AC 250 V/3,500A
3AC 250V/3,500A
0.02...50 A
0.02...30 A
AC 250 V/5,000A
3AC250V/5,000A
DC 80 V/3,500 A
DC 80 V/3500 A
Degree of protection
(IEC 60529/DIN 40050)
Vibration
with toggle down:
directions 1, 2, 3, 4, 5:
with curves F1, F2:
operating area IP40
terminal area IP20
10 g at 0.9 I
N
10 g at 1 x I
N
10 g at 0.8 x I
N
in all planes.
(57-2000 Hz) ± 0.76 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
100 g (11 ms) at 1 x I
N
100 g (11 ms) at 0.8 x I
N
100 g (11 ms) at 0.8 x I
N
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH,
to IEC 60068-2-78, test Cab
approx. 98 g per pole
Shock
directions 1, 2, 3, 4, 5:
direction 6:
with curves F1, F2:
Corrosion
Humidity
Mass
1708
www.e-t-a.de
1
How does a newbie learn about microcontrollers?
Microcontrollers have become an indispensable part of our lives. Many people may not understand why we say that microcontrollers are everywhere in our lives when we have not seen anything like them. L...
cdhqyj MCU
What is the difference between integrated circuit SAF1091 and SAF1091-173?
When I was repairing an electronic odometer, I found that the integrated circuit SAF1091-173 was broken. Now all the circuits on the market are SAF1091 without the suffix -173. What is the difference ...
jk209350 Integrated technical exchanges
Download the white paper "Safety of Medical Power Supplies" for free!
[size=4][url=https://zh-cn.artesyn.com/power/support/customer-resources/whitepapers/medical-power-supply][/url] [font=微软雅黑]Modern medical devices take advantage of advances in computing and electronic...
eric_wang Medical Electronics
Problems encountered when judging whether SD software communication exists. Help!!!
I use software communication to determine whether the SD card communication is normal or abnormal, and I encounter a very strange phenomenon: If I use a programmer to download the program, it can be j...
liwenjie518 Embedded System
Looking for Chinese information on IPMI. All 200 points are gone!
I need to learn IPMI recently, and I am very depressed when reading the English specification 2.0. Can anyone who has studied IPMI send me some relevant information? I would be very grateful! This is ...
janeyqian Embedded System
Novice help: wince build environment
Dear experts, I have been setting up the development environment of wince for almost a week, but it still hasn't worked. I just want to use visual studio 2005 to develop a program that can run on a mo...
heroboyi Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1281  2612  231  365  2835  26  53  5  8  58 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号