EEWORLDEEWORLDEEWORLD

Part Number

Search

8340-T120-K1T2-ALH0-6A

Description
CIR BRK MAG-HYDR 6A 240VAC/80VDC
CategoryCircuit protection   
File Size402KB,6 Pages
ManufacturerE-Switch
Websitehttp://www.e-switch.com
Download Datasheet Parametric View All

8340-T120-K1T2-ALH0-6A Online Shopping

Suppliers Part Number Price MOQ In stock  
8340-T120-K1T2-ALH0-6A - - View Buy Now

8340-T120-K1T2-ALH0-6A Overview

CIR BRK MAG-HYDR 6A 240VAC/80VDC

8340-T120-K1T2-ALH0-6A Parametric

Parameter NameAttribute value
Circuit breaker typeMagnetic (hydraulic delay)
Rated current6A
Rated voltage - AC240V
Rated voltage - DC80V
Number of poles2
Actuator typepress slice
illuminationnone
Lighting voltage (nominal)-
Installation typeDIN rail
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...
Description
Single, two and three pole magnetic and hydraulic-magnetic circuit
breakers with trip-free mechanism and toggle actuation. A choice of
fast magnetic only or hydraulically delayed switching characteristics
(S-type MO or HM CBE to EN 60934) ensures suitability for a wide
range of applications. Featuring a combi-foot design for symmetric rail
mounting. Low temperature sensitivity at rated load.
Approved to CBE standard EN 60934 (IEC 60934).
Typical applications
Power supplies, control equipment, communication systems, EDP
systems.
Standard current ratings and typical internal resistance values
Current
rating (A)
0,02
0,05
0,1
0,25
0,5
0,75
1
2
2,5
3
5
6
8
10
12
15
16
20
25
30
40
50
Internal resistance values (Ω) per pole
F1
1 493
276
58
8,2
2,3
0,98
0,58
0,145
0,096
0,065
0,025
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,01
< 0,01
953
152
37
6,0
1,47
0,63
0,35
0,096
0,061
0,048
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
-
-
F2
K1, M1, T1
2 669
452
100
15,5
3,9
1,65
0,95
0,26
0,15
0,10
0,042
0,029
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,01
< 0,01
K2, M2, T2
2 457
376
94
14,7
3,2
1,56
0,90
0,20
0,15
0,10
0,040
0,028
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
-
-
single pole
8340-T...
1
three pole
Technical data
For further details please see chapter: Technical Information
Voltage rating
3 AC 415V; AC 240V (50/60Hz); DC 80V
(higher DC voltages to special order)
Current rating range
0.02...50 A DC
0.02...30 A AC
Auxiliary circuit
1 A, AC 240 V/DC 65 V; 0.5 A DC 80 V
Typical life
3 AC 415 V AC 240 V:
0.02...30 A 6,000 operations at 1 x I
N
, inductive
10,000 operations at 1 x I
N
, resistive
WDC 80 V: 0.02...25 A 6,000 operations at 1 x I
N
, inductive
0.02...30 A 10,000 operations at 1 x I
N
, resistive
40 + 50 A 6,000 operations at 1 x I
N
, resistive
Ambient temperature
-40...+85 °C (-40...+185 °F)
Insulation co-ordination
rated impulse
pollution
(IEC 60664 and 60664A)
withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A)
operating area
test voltage AC 3,000 V
Line to Load
test voltage AC 1,500 V
pole to pole
(2- and 3-pole)
test voltage AC 1,500 V
main to auxiliary circuit test voltage AC 1,500 V
Insulation resistance
> 100 MΩ (DC 500 V)
Interrupting capacity
6 x IN at AC;
IEC 60934 - test sequence E 4 x IN at DC
Interrupting capacity
I
N
0.02...20 A
25...30 A
(UL 1077)
AC:
1-pole AC 250 V/3,500A AC 250 V/3,500A
2-pole
3-pole
DC:
1-pole
2-pole
AC 250 V/3,500A
3AC 250V/3,500A
0.02...50 A
0.02...30 A
AC 250 V/5,000A
3AC250V/5,000A
DC 80 V/3,500 A
DC 80 V/3500 A
Degree of protection
(IEC 60529/DIN 40050)
Vibration
with toggle down:
directions 1, 2, 3, 4, 5:
with curves F1, F2:
operating area IP40
terminal area IP20
10 g at 0.9 I
N
10 g at 1 x I
N
10 g at 0.8 x I
N
in all planes.
(57-2000 Hz) ± 0.76 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
100 g (11 ms) at 1 x I
N
100 g (11 ms) at 0.8 x I
N
100 g (11 ms) at 0.8 x I
N
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH,
to IEC 60068-2-78, test Cab
approx. 98 g per pole
Shock
directions 1, 2, 3, 4, 5:
direction 6:
with curves F1, F2:
Corrosion
Humidity
Mass
1708
www.e-t-a.de
1
MSP430G2553 Study Notes—2
(IV) ADC10 1. ADC10 is a 10-bit AD. There are eight external AD channels A0~A7 on g2553. A10 is connected to the on-chip temperature sensor, and the other channels are connected to the internal VCC or...
qinkaiabc Microcontroller MCU
What You Need to Know About Transimpedance Amplifiers – Part 1
[align=left][color=#000]A transimpedance amplifier (TIA) is a front-end amplifier for optical sensors such as photodiodes that converts the output current of the sensor into a voltage. The concept of ...
maylove Analogue and Mixed Signal
Preisach-type hysteresis nonlinear modeling and inverse control application of power amplifier based on hyperbolic function
Experiment name: Preisach type hysteresis nonlinear modeling and inverse control based on hyperbolic function Experimental content: Drivers made of smart materials such as piezoelectric ceramics and m...
aigtek01 LED Zone
mqx binary size
The minimum mqx kernel is 6k, but I don't know how big the maximum (full-featured, such as file system, etc.) kernel is? xiexie!...
c_tongtong@qq.c NXP MCU
Does anyone know what type of CPU is used in common scientific calculators? 51 series or other? Thanks!
I want to build a hardware platform to make a scientific calculator. When I disassembled my calculator, I only saw a bare chip and a big black mole. I couldn't see anything inside. I'm so depressed! D...
YaoHui Embedded System
A microcontroller experiment, urgent, please help me
1. Display circuit The LED display circuit and keyboard circuit of this experimental instrument are shown in Figure 1. The bit code of display control is output by 74HC374, and after being reverse dri...
kiny Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1249  1646  16  2886  853  26  34  1  59  18 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号