EEWORLDEEWORLDEEWORLD

Part Number

Search

RE-243.3S/HP

Description
DC DC CONVERTER 3.3V 1W
CategoryPower/power management   
File Size1MB,6 Pages
ManufacturerRECOM Power GmbH
Websitehttps://www.recom-power.com/
Environmental Compliance
Download Datasheet Parametric View All

RE-243.3S/HP Overview

DC DC CONVERTER 3.3V 1W

RE-243.3S/HP Parametric

Parameter NameAttribute value
typeisolation module
Number of outputs1
Voltage - Input (minimum)21.6V
Voltage - input (maximum)26.4V
Voltage - Output 13.3V
Voltage - Output 2-
Voltage - Output 3-
Current - Output (maximum)303mA
Power (W)1W
Voltage - Isolation2kV
applicationITE (Business)
characteristicSCP
Operating temperature-40°C ~ 85°C
efficiency75%
Installation typeThrough hole
Package/casing7-SIP module, 4-lead
size/dimensions0.77" long x 0.24" wide x 0.40" high (19.7mm x 6.0mm x 10.2mm)
Features
Unregulated
Converters
Description
• Industry standard pinout
• 1kVDC or 2kVDC isolation
• UL94 V-0 package material
• Fully encapsulated
• Efficiency up to 85%
DC/DC Converter
RO
1 Watt
SIP4
Single Output
The RO DC/DC converters are typically used in general purpose power isolation and voltage
matching applications, and feature a full industrial operating temperature range of -40°C to +85°C
without derating.
Selection Guide
Part
Number
RO-xx3.3S
(3,4)
RO-xx05S
(3,4)
RO-xx09S
(3,4)
RO-xx12S
(3,4)
RO-xx15S
(3,4)
nom. Input
Voltage
[VDC]
3.3, 5,12, 15, 24
3.3, 5,12, 15, 24
3.3, 5,12, 15, 24
3.3, 5,12, 15, 24
3.3, 5,12, 15, 24
3.3, 5,12, 15, 24
Output
Voltage
[VDC]
3.3
5
9
12
15
24
Output
Current
[mA]
303
200
111
83
66
42
Efficiency
typ.
(1)
[%]
75
78-80
78-80
80-84
80-84
78-85
max. Capacitive
Load
(2)
[µF]
2200
1000
1000
470
470
220
RO-xx24S
(3,4)
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max Cap Load is tested at nominal input and full resistive load and is defined as the
capacitive load that will allow start up in under 1s without damage to the converter
E358085
Model Numbering
RO- __ __S/_
Input Voltage
Output Voltage
Protection
(3)
Isolation Option
(4)
Single
Notes:
Note3: standard part is without Continuous Short Circuit Protection
add suffix „/P“ for Continuous Short Circuit Protection
Note4: add suffix „/H“ for 2kVDC Isolation
or add suffix „/HP“ for Continuous Short Circuit Protection and 2kVDC Isolation
Ordering Examples:
RO-123.3S/P: 12V Input Voltage, 3.3V Output Voltage, Single Output with continuous short circuit protection
RO-0509S/HP: 5V Input Voltage, 9V Output Voltage, Single Output with 2kVDC Isolation and continuous short circuit protection
IEC60950-1 certified
EN60950-1 certified
UL60950-1 certified
CB Report
www.recom-power.com
REV.: 1/2018
ECO-1

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 281  477  1333  751  1482  6  10  27  16  30 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号