CIRC BRKR HYDRAULIC MAGNETIC
CategoryCircuit protection   
File Size455KB,6 Pages
ManufacturerE-Switch
Websitehttp://www.e-switch.com
Download Datasheet View All

8340-F410-P1M1-KNH142-2A Online Shopping

Suppliers Part Number Price MOQ In stock  
8340-F410-P1M1-KNH142-2A - - View Buy Now

8340-F410-P1M1-KNH142-2A Overview

CIRC BRKR HYDRAULIC MAGNETIC

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...
Description
Single and multipole magnetic circuit breakers with trip-free
mechanism and toggle actuation. A choice of fast magnetic only or
hydraulically delayed switching characteristics (S-type MO or HM
CBE to EN 60934) ensures suitability for a wide range of applications.
Industry standard dimensions and panel mounting. Options include
auxiliary changeover contacts. Low temperature sensitivity at rated
load.
Approved to CBE standard EN 60934 (IEC 60934).
Typical application
Control equipment, communications systems, transportation, power
supplies.
1-pole
8340-F...
1
2-pole
Standard current ratings and typical internal resistance values
Current
rating (A)
0,02
0,05
0,1
0,25
0,5
0,75
1
2
2,5
3
5
6
8
10
12
15
16
20
25
30
40
50
Internal resistance values (Ω) per pole
F1
1 493
276
58
8,2
2,3
0,98
0,58
0,145
0,096
0,065
0,025
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,01
< 0,01
953
152
37
6,0
1,47
0,63
0,35
0,096
0,061
0,048
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
-
-
F2
K1, M1, T1
2 669
452
100
15,5
3,9
1,65
0,95
0,26
0,15
0,10
0,042
0,029
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,01
< 0,01
K2, M2, T2
2 457
376
94
14,7
3,2
1,56
0,90
0,20
0,15
0,10
0,040
0,028
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
< 0,02
-
-
Technical data
For further details please see chapter: Technical Information
Voltage rating
3 AC 415 V; AC 240 V, 50/60 Hz; DC 80 V
(higher DC ratings to special order)
Current ratings
0.02...50 A DC
0.02...30 A AC
Auxiliary circuit
6 A, AC 240 V;
3 A, DC 28 V
1 A, DC 65 V;
0.5 A, DC 80 V
Typical life
3 AC 415 V, AC 240 V:
0.02...30 A
6,000 operations at 1 x I
N
, inductive
10,000 operations at 1 x I
N
, resistive
DC 80 V: 0.02...25 A
6,000 operations at 1 x I
N
, inductive
0.02...30 A
10,000 operations at 1 x I
N
, resistive
40 + 50 A
6,000 operations at 1 x I
N
, resistive
Ambient temperature
-40...+85 °C (-40...+185 °F)
Insulation co-ordination
rated impulse
pollution
(IEC 60664 and 60664A) withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A)
operating area
test voltage AC 3,000 V
Line to Load
test voltage AC 1,500 V
pole to pole
(2- and 3-pole)
test voltage AC 1,500 V
main to auxiliary circuit
test voltage AC 3,000 V
switching to trip circuit
test voltage AC 1,500 V
(version -X)
Insulation resistance
> 100 MΩ (DC 500 V)
Interrupting capacity
6 x IN at AC;
IEC 60934 - test sequence E 4 x IN at DC
Interrupting capacity
(UL 1077)
AC:
1-pole
2-pole
3-pole
1-pole
2-pole
I
N
0.02...20 A
25...30 A
AC 250 V/3,500A AC 250 V/3,500A
AC 250 V/3,500A AC 250 V/5,000A
3AC 250V/3,500A 3AC250V/5,000A
0.02...50 A
0.02...30 A
DC 80 V/3,500 A
DC 80 V/3500 A
DC:
Degree of protection
(IEC 60529/DIN 40050)
Vibration
with toggle down:
directions 1, 2, 3, 4, 5:
Shock
Corrosion
Humidity
Mass
1747
www.e-t-a.de
operating area IP40
terminal area IP00
10 g (57-2000Hz) ± 0.76 mm (10-57 Hz)
at 0.9 x IN
10 g (57-2000 Hz) at 1 x IN.
100 g (11 ms) at 1 x IN, directions 1,2,3,4,5
100 g (11 ms) at 0.8 x IN, direction 6.
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH
to IEC 60068-2-78, test Cab
approx. 65 g per pole
1
Ask an expert about cpld
The pins of the cpld that connect +3.3V and ground start to smoke when powered on or when downloading a program, but there seems to be no short circuit on the board. Has anyone encountered a similar s...
hypetrel FPGA/CPLD
To be strangled in the cradle, or to break out of the cocoon?
In May 2006, Shanghai Qingyue Software Co., Ltd. officially launched the research and development of the PCB software Qingyuefeng, and it began to be sold on the market in October 2008. It is only 3 o...
winnies PCB Design
Why is my program behaving like this?
I am using S3C44B0 to do an LED light experiment (cycle lighting), and debugging in AXD is successful. Then I burned the .AXF file into the board using FlashProgrammer, and found that after unplugging...
2315862 Embedded System
Please tell me the specific steps to port ucosII/gui to pc through vc++
I have little experience in this area and have no idea. Please give me some advice....
吃吃吃包子 DSP and ARM Processors
6410 NK operation and USB download issues?
I have made a 6410 board myself. The current situation is as follows: In the BSP provided by Samsung, NK has three speeds, the first is 532MHz, 133MHz, 66.5MHz, the second is 600MHz, 150MHz, 75MHz, an...
wangyurui Embedded System
Problems in PCB design
I would like to ask what does Ground plane removed under Vin- mean in this picture? Does it mean that V- should be separated when laying ground in PCB design? Why should it be separated?...
星星brisk PCB Design

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2231  1537  639  2118  599  45  31  13  43  59 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号