EEWORLDEEWORLDEEWORLD

Part Number

Search

D4N-2CLE

Description
SWITCH SNAP ACTION 3PST 10A 120V
CategoryMechanical and electronic products    switch   
File Size6MB,20 Pages
ManufacturerOMRON
Websitehttps://www.omron.com
Environmental Compliance
Download Datasheet Parametric View All

D4N-2CLE Online Shopping

Suppliers Part Number Price MOQ In stock  
D4N-2CLE - - View Buy Now

D4N-2CLE Overview

SWITCH SNAP ACTION 3PST 10A 120V

D4N-2CLE Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerOMRON
Reach Compliance Codeunknown
ECCN codeEAR99
Factory Lead Time14 weeks
Actuator typeFORK LEVER LOCK
body width30 mm
body height57.5 mm
Body length or diameter31 mm
Contact (AC) maximum rated R load10A@240VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)2.5 A
Contact (DC) maximum rated R load2.5A@250VDC
Maximum contact voltage (AC)240 V
Maximum contact voltage (DC)250 V
Electrical life300000 Cycle(s)
Manufacturer's serial numberD4N
Installation featuresPANEL MOUNT
Maximum operating force6.4 N
Maximum operating temperature70 °C
Minimum operating temperature-30 °C
sealIP67
surface mountNO
Switch actionMOMENTARY
switch function3PST
Switch typeSNAP ACTING/LIMIT SWITCH
Termination typeSCREW
Safety Limit Switch
D4N
CSM_D4N_DS_E_10_1
Popular Safety Limit Switches
Providing a Full Lineup Conforming to
International Standards
• Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and
3NC contact forms.
(Slow-action models with MBB contacts are available.)
• M12-connector models are also available, saving on labor and
simplifying replacement.
• Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
• Conforms to the requirements for safety contacts in EN 115-1,
EN 81-20, and EN 81-50 (slow-action models only).
• Certified standards: UL, EN (TÜV), and CCC
Be sure to read the
“Safety Precautions”
on page 17.
Note:
Contact your sales representative for details on models
with safety standard certification.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Model Number Structure
Model Number Legend
1-Conduit Models
2-Conduit Models
D4N-@@@@
1 2
3
1. Conduit size
1: Pg13.5
2: G1/2
4: M20
9: M12 connector
2. Built-in Switch
1: 1NC/1NO (snap-action)
2: 2NC (snap-action)
A: 1NC/1NO (slow-action)
B: 2NC (slow-action)
C: 2NC/1NO (slow-action)
D: 3NC (slow-action)
E: 1NC/1NO (MBB contact) (slow-action)
F: 2NC/1NO (MBB contact) (slow-action)
3. Head and Actuator
20: Roller lever (resin lever, resin roller)
22: Roller lever (metal lever, resin roller)
25: Roller lever (metal lever, metal roller)
26: Roller lever (metal lever, bearing roller)
2G: Adjustable roller lever, form lock (metal lever, resin roller)
2H: Adjustable roller lever, form lock (metal lever, rubber roller)
31: Plunger
32: Roller Plunger
62: One-way roller arm lever (horizontal)
72: One-way roller arm lever (vertical)
80: Cat whisker
87: Plastic rod
RE: Fork lever lock (right operation)
LE: Fork lever lock (left operation)
D4N-@@@@
1 2
3
1. Conduit size
6: G1/2
8: M20
2. Built-in Switch
1: 1NC/1NO (snap-action)
2: 2NC (snap-action)
A: 1NC/1NO (slow-action)
B: 2NC (slow-action)
C: 2NC/1NO (slow-action)
D: 3NC (slow-action)
E: 1NC/1NO (MBB contact) (slow-action)
F: 2NC/1NO (MBB contact) (slow-action)
3. Head and Actuator
20: Roller lever (resin lever, resin roller)
22: Roller lever (metal lever, resin roller)
25: Roller lever (metal lever, metal roller)
26: Roller lever (metal lever, bearing roller)
2G: Adjustable roller lever, form lock (metal lever, resin roller)
2H: Adjustable roller lever, form lock (metal lever, rubber roller)
31: Plunger
32: Roller Plunger
62: One-way roller arm lever (horizontal)
72: One-way roller arm lever (vertical)
1
12864 The screen is cleared very slowly when drawing waveforms
I made a heartbeat monitoring system driven by 12864. It takes nearly 1 second to clear the screen after scanning 128 bits each time. I would like to ask experts to give me some advice. Have you encou...
ylylyl007 Microcontroller MCU
External RAM Issues
[i=s] This post was last edited by dontium on 2015-1-23 13:29 [/i] After soldering a batch of 2812 circuit boards, it was found that most of the board programs could not be loaded into the external RA...
chenquan Analogue and Mixed Signal
Chinese Notes for uCOS-II
This is a source code of uCOS-II with Chinese annotations that I share. It is very good and I hope it will be helpful to those who need it. Some people pass on some information and charge for it. Alas...
wzlong2012 Real-time operating system RTOS
I would like to ask about the ADUC7060 issue, thank you!
I just got started with ADUC7060. When debugging UART, I can operate the sending and receiving sampling query methods, but I can't get into the interrupt when I want to receive. int main(void) { POWKE...
kami03372 ADI Reference Circuit
NUCLEO_G431RB Review: Get G431
[i=s]This post was last edited by viphotman on 2019-9-18 11:04[/i]ST NUCLEO_G431RB review 1. Hardware1 Take a photo of the real object with your mobile phone. You can see two ICs: STM32F723. This is u...
viphotman stm32/stm8
Common module circuit set
Let’s learn about some commonly used modules....
工一 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 943  2243  717  318  888  19  46  15  7  18 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号