Part Number

Search

DG160-3

Description
AC/DC CONVERTER 18V 160W
CategoryPower/power management   
File Size2MB,2 Pages
ManufacturerCurtis Industries
Environmental Compliance
Download Datasheet Parametric View All

DG160-3 Overview

AC/DC CONVERTER 18V 160W

DG160-3 Parametric

Parameter NameAttribute value
typeopen framework
Number of outputs1
Voltage - input90 ~ 264 VAC
Voltage - Output 118V
Voltage - Output 2-
Voltage - Output 3-
Voltage - Output 4-
Current - Output (maximum)8.9A
Power (W)160W (240W forced air cooling)
applicationITE (Business)
efficiency91%
Operating temperature-20°C ~ 70°C (with derating)
characteristicPFC, standby output, universal input
Installation typeBase installation
size/dimensions5.00" long x 3.00" wide x 1.42" high (127.0mm x 76.2mm x 36.1mm)
Minimum load required-
Approval-
Power
Supplies
160W/360W Peak
Built-in active PFC
UL/CSA/EN 60950-1, 2
nd
edition (ITE)
ANSI/ANMI/CSA/EN 60601-1, 3
rd
edition (Medical)
Efficiency: 90% typical
Operation from -20°C to 65°C - convection
Approved for 2xMOPP applications
U-Frame (EU) and enclosed (EC) versions available
10 year warranty
EU Option
EC Option
Description
The
DG160 (ITE)
and
DG160M (Medical) Series
is a 160 Watt Open Frame power supply that is 3’’x 5’’x 1.42’’ providing
8.9 Watts per cubic inch. Each unit has a built in Active Power Factor Correction and the efficiency of the series is between
89% to 91% depending on model. The DG160 is compliant with Green power, Energy Star Level VI and ErP EC 1275/2008.
The Series is rated at 160 Watts free air convection cooling and up to 240 Watts with 18CFM forced air. This series is available
with an optional “U” frame or covered metal enclosure.
Specifications
Input
Input Voltage
Input Frequency
Inrush Current
Power Factor
Input Protection
No Load Input Power
Input Current
90 VAC to 264 VAC, 115/230V nominal
47 Hz to 63 Hz
< 30/60A at 115/230 VAC, cold start, 25ºC
>0.9
Internal T3.15 A / 250 VAC fuse in line
< 0.5W (< 1.5W for “A” version)
4A max at 115 VAC, 2A max at 230VAC
General
Efficiency
Energy Saving
Isolation
90% typical at rated load
Energy Star, Level VI
4000 VAC Input to Output, 2 x MOPP
1500 VAC Input to Ground, 1 x MOPP
1500 VDC Output to Ground, 1 x MOPP
50 MΩ
120 kHz typical
>TBD kHrs to MIL-HDBK-217F at 50°C
Isolation Resistance
Switching Frequency
MTBF
Output
Output Voltage
Initial Set Accuracy
Minimum Load
Start Up Rise Time
Hold Up Time
Line Regulation
Load Regulation
Ripple & Noise
Overvoltage Protection
Overload Protection
Short Circuit Protection
See tables on page 2
See tables on page 2
No minimum load required
2 ms typical
> 20 ms typical
±0.5% typical
±1.0% typical
< 1% pk-pk typical, 20MHz Bandwidth
latch off
auto recovery
auto recovery
EMC & Safety
                                           •
Harmonic Currents    
EMI                                   •
ESD Immunity
Radiated Immunity
EFT Burst
Surge
Conducted Immunity
Magnetic Fields
Dips & Interruptions
Safety Approvals:           
UL/CSA/EN 60950-1, 2nd edition (ITE)
ANSI/AMMI/CSA/EN 60601-1, 3rd edition
CE Mark and CB report
EN 61000-3-2 class D
EN55022 (CISPR 22) Class B, EN 61000-3-3
EN 61000-4-2, 6kV/contact, 8kV/air
EN 61000-4-3, 10V/m with 80% AM
EN 61000-4-4, 2kV
EN 61000-4-5, 1kV/L-L, 2kV/L-G
EN 61000-4-6, 10V with 80% AM
E61000-4-8, 10A/m
EN 61000-4-11, 30% dips 10ms, 60%
dips 100ms, 95% dips 5000ms
Environmental
Operating Temperature
Cooling
Operating Humidity
Storage Temperature
Altitude
-20°C to 65°C
derating: 3.33% / ºC > 50°C
160W; free air convection
240W; 18CFM forced air
5-95% RH, non-condensing
-40°C to +85°C
0 to 3000 m
Warranty
Manufacturer’s Warranty
10 years. Call Tri-Mag or go to
www.Tri-Mag.com for details.
1601 N. Clancy Ct. • Visalia, CA 93291 • (559) 651-2222 • FAX (559) 651-0188 • sales@tri-mag.com •
tri-mag.com
1 of 2
GREEN POWER
DG160 Series
|
ITE & Medical Safety
I want to DIY a practical TI M4 board. Which resources do you prefer?
I want to DIY a TI M4 board based on TI's latest M4 chip.Let's see what functions you would like this board to have if it is based on the M4 chip?Looking forward to everyone's suggestions~~~~~~...
绿茶 Microcontroller MCU
Don't read those compiler theory books! This book teaches you how to write real practical programming techniques!
Forget about those compiler theory books! This book teaches you how to write truly practical parsers, translators, interpreters and other language applications. Terence Parr explains in detail the use...
tiankai001 Download Centre
Analysis of the current status and trends of medical electronic technology
Analysis of the current status and trends of medical electronic technology ADC with a resolution of 16 bits and a sampling rate of 170MSPS, LCD screen with a pixel count of 2560*2048 and a grayscale d...
simonprince Medical Electronics
ADI's ADUCM360 chip cannot run without JLINK
[color=#000]I encountered the following problem when developing with ADUCM: [/color] [color=#000]Problem description: I can simulate and download normally with JLINK, and it can run normally when I di...
tljgas ADI Reference Circuit
What is the practical significance of the bus?
The network label already connects the two ports, so the bus has no practical use, right? It's just for the convenience of checking the network label?...
44444444444444 MCU
[Help] About the zigbee network topology display problem
Does z-stack sensor monitor support every z-stack protocol stack routine? Why are some networks not displayed? I know that sensor monitor seems to have its own protocol. Can someone please give me som...
nku_zy RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2770  626  2007  1218  207  56  13  41  25  5 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号